7890B GC System
- GC Systems
Request a Quote
Product Details
- Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
- Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
- Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
- Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
- Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
- Helium conservation module and alternative carrier gas solutions dramatically reduce the amount of helium used to offer flexibility and cost savings for your laboratory
- Optional Hydrogen Sensor Module Series 2 detects hydrogen leaks early and shuts off gas flows, continuously monitors status using built-in intelligent diagnostics, and requires calibration only every six months
- Large Valve Oven (LVO) allows for the combination of multiple methods and simplified maintenance
- Multimode inlet (MMI) serves as a programmable temperature vaporizing injector with flexible capabilities
- Agilent Inert Flow Path provides increased sensitivity for active compounds, from injection to detection
- Low Thermal Mass (LTM) modules, up to 4 installed and operating, increase sample throughput with rapid column heating and cooling
Improve Your Gas Chromatography with Backflush
Capillary Flow Technology enables flexible implementation of backflush on Agilent GCs for higher throughput, less maintenance, fewer recalibrations, longer column life, better results, and lower costs.
Learn MoreHelium Conservation Module
A helium conservation module for 8890, 8860, or 7890 GC systems can drastically reduce your consumption of helium carrier gas and the associated cost, especially when used with Gas Saver. It can be programmed to switch to a different gas (typically nitrogen) when your GC is idle. The module is compatible with any inlet, backflush, and dual simultaneous injections.
Learn MoreMultidimensional Gas Chromatography
Multidimensional chromatography introduces a second column with a different stationary phase into the flow path. Complex samples often have coeluting compounds so adding the selectivity of an additional column through heart cutting or GC x GC increases the GC resolving power and provides a solution to the problem of overlapping peaks.
Learn MoreRetention Time Locking (RTL)
Retention time locking (RTL) enables the retention times on one Agilent GC or GC/MSD system to be matched exactly on another like system using the same nominal column.
Learn More- Key Literature
-
Agilent 7890B Network Gas Chromatograph Data Sheet
The Agilent 7890B is a state-of-the-art gas chromatograph that provides superior performance for all GC applications.
- Data Sheets
- English
- 29 Aug 2013
- 466.76 KB
Agilent 7890B GC Supplies Quick Reference Guide
This quick reference guide lists the commonly ordered parts and supplies for the Agilent 7890B GC. we have produced this list of the most commonly ordered supplies and parts for the 7890B GC. Keep this list handy so you can quickly find the supplies you need and minimize instrument downtime.
- Brochures
- English
- 05 Jan 2021
- 604.22 KB
- Application Notes
- Brochures
- Data Sheets
- Flyers
- Newsletters
- Posters
- Technical Overviews
- White Papers
- Support
-
7890B GC Operation Manual
7890B GC Operation Manual contains common keyboard functions, using the keyboard when connected to an Agilent data system, methods and se
- User Manuals
- English
- 29 Dec 2017
- 3.60 MB
7890 Series GC Troubleshooting Guide
7890 Series GC Troubleshooting Guide
- User Manuals
- English
- 29 Dec 2017
- 5.10 MB
- FAQs
- Firmware
- Quick Reference Guides
- Site Preparation Checklists
- Software Utilities
- Troubleshooting Guide
- User Manuals
More help is just a click away
If you didn't find what you need, try these resources or contact a specialist
GC Productivity Tools
Optimize GC methods using vapor volume, pressure flow, and solvent vent calculators or method translation software.
Helium Conservation Cost Savings Calculator
See how much helium and money you could save using Gas Saver and a helium conservation module for nitrogen standby.
GC Firmware Update Utility
Update the firmware on current and older GC systems and accessories, such as autosamplers and headspace samplers.
Videos
Handle the Hassles of the Helium Shortage – Conserve or Convert
Learn how to best manage the ongoing helium shortage to help minimize disruptions to your lab operations and budget. Discover ways to conserve helium or get guidance on switching to an alternative GC carrier gas. A new tool calculates how much you might save if you choose conservation.
- 01 Feb 2022