Cary 3500 Compact UV-Vis Spectrophotometer
Cary 3500 Compact UV-Vis Spectrophotometer
The Cary 3500 comes complete with Cary UV Workstation software—a next-generation analytical platform with streamlined methods for wavelength reads, scanning, concentration, kinetics, and temperature measurements. When configured with Agilent OpenLab data management software, Cary UV Workstation data is managed, protected, and stored in a local or central secure database.
- UV-Vis & UV-Vis-NIR Instruments
Product Details
- Perform accurate and quick temperature-controlled experiments from -5 to 110 °C using a unique and fully integrated air-cooled Peltier system.
- Control experimental temperature from inside the cuvette using highly accurate, solid-state digital Cary temperature probes with thermal ramp rate up to 40 °C/min.
- Ensure accurate analysis of small-volume measurements with a highly-collimated and uniform beam of less than 1.5 mm width, coupled with permanent optical alignment of the stationary cell holders.
- Reduce data processing time and calculation errors with more than 50 built-in and customized calculations that can be saved and applied automatically to any method used routinely.
- Achieve research grade photometric performance, stability, and range with a double beam spectrophotometer featuring leading optical technologies.
- Be up and running in minutes by following the intuitive video tutorials in Cary UV Workstations Help and Learning Center.
- Meet data integrity standards—provides the technical controls to securely acquire, process, report and store data in laboratories that must follow the compliance guidelines of FDA 21 CFR Part 11, EU Annex 11, GAMP5, as well as ISO/IEC 17025 and EPAs 40 CFR Part 160.
- Store and manage your Cary 3500 Compact UV-Vis spectrophotometer data in a local secured storage on the workstation PC, or in a central storage location.
- Deploy the OpenLab software suite and get optional secure database storage for electronic records, complete administration for users and access privileges, software licensing, and security settings—e-signature workflow and enhanced audit trail review capabilities.
- Choose sustainability: The Cary 3500 Compact UV-Vis received My Green Labs ACT (Accountability, Consistency, Transparency) label after independent audit for its environmental impact throughout the product lifecycle.
| Compliance Software |
|
| Control Software |
|
| Depth |
|
| Height |
|
| Light Source |
|
| Maximum Scanning Speed |
|
| Photometric Range (Abs) |
|
| Photometric System |
|
| Power Requirements |
|
| Spectral Bandwidth |
|
| Wavelength |
|
| Weight |
|
| Width |
|
| Z-height |
|
Xenon Flash Lamps for UV-Vis & Fluorescence Spectrophotometers
For more than 35 years, Agilent has been the pioneer in xenon flash lamp technology for UV-Vis and fluorescence instrumentation. Agilent provides innovative workflow solutions using xenon lamps, including our 10-year lamp warranty, on Cary 60 UV-Vis, Cary 3500 UV-Vis, and Cary Eclipse Fluorescence spectrophotometers.
Learn MoreUV-Vis Analysis of Biomolecules
Analyzing proteins, oligos, monoclonal antibodies, and other biomolecules? UV-Vis spectroscopy is a key part of any bioanalytical toolkit, with many features and benefits that accelerate workflows involving biomolecules. Read our guide and customer case studies to learn more.
Learn MoreDouble Beam Spectrophotometers
Double beam spectrophotometers are fast and accurate, using two beams of light—a sample beam and a reference beam—to correct instrument fluctuations in real-time.
Learn More- Key Literature
-
Cary 3500 UV-Vis Brochure
Learn about the Agilent Cary 3500 UV-Vis spectrophotometer
- Brochures
- English
- 04 Sep 2024
- 4.87 MB
Amplify Confidence in Your Data Integrity
How to get the functionality you need for compliance with 21 CFR Part 11 or EU Annex 11 when using the Agilent Cary 3500 UV-Vis instrument.
- Flyers
- English
- 29 Aug 2022
- 749.43 KB
10-Year Xenon Flash Lamp Replacement Warranty - Cary 3500 UV-Vis
The Agilent Cary 3500 UV-Vis series offers flexibility in sample measurement with multiple modules. The xenon flash lamp reduces frequency and cost of lamp replacement and is covered by a 10-year warranty.
- Flyers
- English
- 11 Mar 2024
- 683.75 KB
- Application Notes
- Brochures
- Catalogs
- Flyers
- Primers
- Technical Overviews
- White Papers
- FAQs
-
UV-Vis Spectroscopy and Spectrophotometry Overview
An introduction to the basics of UV-Vis spectroscopy and UV-Vis spectrophotometers, with FAQs on the fundamentals of UV-Vis, how UV-Vis spectrophotometers work, UV-Vis analysis, applications, accessories, and measurement techniques.
- Instruction Sheets
- Site Preparation Checklists
- Supplemental Information
- User Manuals
More help is just a click away
If you didn't find what you need, try these resources or contact a specialist
Upgrade Cary UV Workstation: Smarter Reporting, Advanced Calculations, Seamless Compliance
Upgrade to Cary UV Workstation v1.6 for smarter workflows and customizable reporting. Autogenerate PDF/CSV reports, export to custom locations, and scale graphs for clarity. Use 50+ built-in or custom equations with sample metadata. Overlay spectra for easy comparisons. Supports USP <857>, Ph. Eur. 2.2.25, JP XVIII, OpenLab 2.8, ECM 3.6, and Windows 10/11 for compliance and seamless integration.
- 08 Oct 2025
White Paper: Spectroelectrochemistry Using Agilent UV-Vis-NIR Spectrophotometers
Spectroelectrochemistry (SEC) combines electrochemistry and spectroscopy, allowing for the simultaneous observation of optical and electrical properties. This technique is critical for developing advanced energy solutions and technologies. The white paper provides an overview of SEC and highlights research using Cary UV-Vis/NIR spectrophotometers to study redox behavior and detect intermediates in electrochemical processes.
- 27 Jan 2025
Join Our Webinar on Oligonucleotides ID Testing with Vetter Pharma
This webinar, hosted by Agilent and delivered by Vetter Pharma, focuses on the identification of oligonucleotides in pharmaceutical quality control (QC). Attendees will gain insights into cutting-edge technologies and best practices for enhancing laboratory efficiency and accuracy. Register now to watch live or on demand.
- 21 Nov 2024
Read reviews on the Cary 3500 UV-Vis Spectrophotometer
Explore customer reviews posted on SelectScience, or write your own review.
UV-Vis Pharmaceutical Compliance & Data Integrity
Learn about meeting UV-Vis compliance requirements, protecting data, and guaranteeing accurate results.
Multicell UV-Vis Spectrometer Applications
Discover unique multicell UV-Vis experiment capabilities—for routine analysis and challenging measurements.
UV-Vis Spectroscopy Learning Tools
Get your Basics of UV-Vis Spectrophotometry handbook, and a pack of four undergraduate teaching lab experiments.
UV-Vis & UV-Vis-NIR Instrument Selection Guide
Find out which Agilent UV-Vis or UV-Vis-NIR spectrophotometer is best for your needs.
Dr. Mohammad Al Kobaisi
School of Chemistry and Biotechnology, Swinburne University of Technology
Agilent’s Cary 3500 with controlled stirring and wide range of temperature control options has converted me to use UV-vis spectroscopy to monitor processes in situ using this instrument. The stability of the signal allows for long term kinetic processes too, opening up a range of experiments I was unable to do beforehand due to drift. The intuitive software and data management prevents the loss of results and ensure well organized projects and archives. The Cary 3500 is most definitely an exciting advancement from any other UV-vis spectrometer I have used previously, expanding the flexibility to control more parameters while conducting research experiments.