6546 LC/Q-TOF 和 1290 Infinity II HPLC
6546 LC/Q-TOF
采用 Q-RAI(四极杆分辨全离子)或全离子采集功能后,现可将食品安全筛查与片段信息结合用于鉴定,让您执行目标物和疑似物的同步筛查。此外,高分辨率、宽动态范围与高同位素保真度使 6546 LC/Q-TOF 成为了代谢组学研究的理想平台。
- Quadrupole Time of Flight LC/MS
Request a Quote
Product Details
- 同时提供 5 个数量级的谱内动态范围以及超过 60000(高质量数)和超过 30000(低质量数)的质量分辨率,不论分析物浓度高低,均能获得可靠结果
- 亚 ppm 级的质量数准确度和 5% 以内的同位素保真度,有利于未知物鉴定时缩小可能化合物的范围
- 体验无需放空即可维护离子源和进样口的方便快捷
- 通过农药、兽药、真菌毒素、可萃取物与可浸出物以及水污染物的精确质量谱库,摆脱了化合物数量和耗时的方法维护对靶向筛查分析的限制
- 访问用于代谢谱、脂质组学和定性代谢流分析的代谢组学工作流程
- 使用最新的食品真伪检测工作流程,简化了食品原产地和食品掺假分析流程
| MS 灵敏度(正离子) |
|
| MS 质量准确度(正离子) |
|
| MS 质量准确度(负离子) |
|
| MS 采集速率 |
|
| MS/MS 灵敏度(正离子) |
|
| MS/MS 质量准确度(正离子) |
|
| MS/MS 质量准确度(负离子) |
|
| MS/MS 采集速率 |
|
| TOF 质量分辨率 (FWHM) |
|
| TOF 质量范围 |
|
| 同位素保真度 |
|
| 四极杆分离质量范围 |
|
| 四极杆分辨率 (FWHM) |
|
| 支持的附加软件 |
|
| 无需放真空的维护 |
|
| 极性切换占空比 |
|
| 温度质量稳定性 |
|
| 离子源 |
|
| 谱图内动态范围 |
|
| 软件平台 |
|
- Key Literature
-
Non-Target PFAS Analysis in Dried Blood Spots Using the Agilent 6546 LC/Q-TOF with Profinder and FluoroMatch
This application note demonstrates the use of FluoroMatch Suite for the analysis and identification of per- and polyfluorinated substances (PFAS) using an Agilent1290 Infinity II LC and Agilent 6546 LC/Q-TOF mass spectrometer with iterative exclusion (IE).
- Application Notes
- English
- 13 Mar 2024
- 999.21 KB
Extracellular Flux Analysis and 13C Stable-Isotope Tracing Reveals Metabolic Changes
Combining real-time extracellular flux information with 13C stable‑isotope‑tracing allows greater insight into the mechanism of macrophage activation.
- Application Notes
- English
- 16 Apr 2020
- 733.53 KB
Drug Screening in Whole Blood Using the Agilent 6546 LC/Q-TOF and the LC Screener Tool with Automated Sample Preparation
This application note describes a method for the routine screening of drugs and their related metabolites in whole blood, using the 6546 LC/Q-TOF and Bravo automated linquid handling platform.
- Application Notes
- English
- 18 Mar 2022
- 2.16 MB
- Application Notes
- Brochures
- Case Studies
- Flyers
- Posters
- Technical Overviews
- White Papers
- Support
-
MassHunter Data Acquisition for LC/TOF and LC/Q-TOF Familiarization Guide
This guide teaches you how to use your MassHunter Data Acquisition for Agilent LC/TOF or LC/Q-TOF system.
- Familiarization Checklists
- English
- 13 Jul 2023
- 4.44 MB
MassHunter Workstation 11.0 for LC/TOF and LC/Q-TOF Installation Guide
This book provides instructions to install the MassHunter Workstation software in these configurations: • Workstation (standalone, no content management) • Networked Workstation (networked, with content management on separate server)
- Installation Guides
- English
- 13 Jul 2023
- 967.69 KB
GC/MS and LC/MS MassHunter Workstation and Networked Workstation Requirements Guide
This document details the minimum computer hardware, software, and network requirements as well as the minimum instrument firmware revisions required to run an Agilent MassHunter Workstation or Agilent MassHunter Networked Workstation. Also included are the supported instrument types and Windows operating system configurations.
- Site Preparation Checklists
- English
- 12 Nov 2025
- 1.18 MB
- Quick Reference Guides
- Site Preparation Checklists
- Supplemental Information
- User Manuals
Didn't find what you need? Contact our support team.
Nicola Zamboni, PhD
ETH Zurich, Switzerland
“与之前的 TOF 相比,6546 系统是一次重大进步,主要是由于它能在各种条件(速度、质量数范围、强度)下实现动态范围与出色分辨率的完美结合。对我们来说,6546 系统将成为我们应对挑战性应用的理想仪器,如 13C 代谢流分析、高通量质谱和代谢物鉴定。”
View More