
8890 GC System with 7693A Automatic Liquid Sampler
7693A Automatic Liquid Sampler
The Agilent 7693A ALS (Automatic Liquid Sampler) provides reliable, fast, and precise injections for Agilent GC and GC/MS systems. With additional sample preparation capabilities, this autoinjector can enhance the output of the GC or GC/MS laboratory.
Sample preparation
Dilution, standard addition, and derivatization; save time and eliminate sources of manual error
Next Sample Overlap
Prepare to inject the next sample in the sequence before the GC goes ready; decreasing inject to inject time
Modular Sections
Increase autoinjector capabilities to meet expanding laboratory needs
Dual Simultaneous Injection
Double sample throughput on a single GC system
See the 7693ALS in action here
Parts Finder simplifies parts ordering and troubleshooting.
- Sample Preparation/ Introduction
Product Details
- 150 sample vial tray allows longer unattended operation
- Dual simultaneous injection saves time by doubling sample throughput
- Fast injection technology minimizes needle discrimination and enables use of external standards
- Eliminate introduction of manual error due to sample preparation, including dilution, internal standard addition, and derivatizations
- Holds 250-µL and 500-µl syringes for use in sample preparation
- Easily build and run GC sample preparation programs with Easy SamplePrep software
- Sample heater and mixer dramatically improves high molecular weight chromatographic results
- Heat the entire tray or cool it to sub-ambient temperatures to meet your lab’s needs
- Modular design allows the flexibility to easily move the sampler from GC to GC or start with a single injector and upgrade as needed
- Priority sample capability. There is no need to stop the sequence to add next most important sample
- Barcode reader allows the system to perform specific actions on mismatch, ensuring chain of custody Agilent Barcode Printing Solution.
- Extend the useful life of the 6890N GC by upgrading aging autoinjectors to 7693A
- Ordering Details
- Software and Informatics
- Application Notes
-
Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph
The Agilent 8860 GC was used to analyze a 37-component FAME standard
- Application Notes
- English
- 21 Feb 2019
- 844.40 KB
Analysis of Semivolatile Organic Compounds in Drinking Water on the Agilent 8890 GC and 5977 GC/MSD with Extended Calibration Range
Using US EPA method 525 to study selected SOCs with the Agilent 8890 GC and the Agilent 5977 GC/MSD.
- Application Notes
- English
- 19 Feb 2019
- 1.39 MB
Phthalates Analysis with Method GB 5009.271-2016 Using the Agilent 8890 GC and MSD with Agilent JetClean
A method combining the Agilent 8890 GC with an Agilent 5977B GC/MSD for the analysis of phthalate standards.
- Application Notes
- English
- 08 Feb 2019
- 968.00 KB
Fatty Acid Methyl Esters (FAMEs) Analysis on an Agilent 8890 GC and its Application to Real Samples
Applied methods for FAMEs analysis using long polar column in an 8890 GC
- Application Notes
- English
- 01 Feb 2019
- 1.09 MB
Determination of Multiclass, Multiresidue Pesticides in Olive Oils by Captiva EMR-Lipid Cleanup and GC/MS/MS
Describes a method for pesticide analysis in olive oil with liquid extraction, Agilent Captiva EMR-Lipid cleanup, and GC-MS/MS.
- Application Notes
- English
- 30 Nov 2018
- 992.51 KB
Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS
Application note for the Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS
- Application Notes
- English
- 26 Feb 2018
- 278.72 KB
Increased Thermal Stability and Maximum Temperature Range of Agilent J&W DB-HeavyWAX Column
The increased temperature limit of the Agilent J&W DB-HeavyWAX provides a more thermally stable column, even after 100 hours operating at high temperatures of 280 °C
- Application Notes
- English
- 22 Feb 2018
- 998.18 KB
Industrial Applications with the Agilent J&W DB-WAX Ultra Inert GC Column
Demonstration the excellent inertness performance of the new Agilent J&W DB-WAX Ultra Inert GC column in the analysis of compounds with polar functional groups
- Application Notes
- English
- 03 Apr 2017
- 1.08 MB
Analysis of Distilled spirits Using J&W DB-WAX Ultra Inert Capillary GC Column
Quantification of volatile compounds in distilled spirits with the Agilent J&W DB-WAX UI GC column gives good peak shapes for volatile congeners.
- Application Notes
- English
- 12 Apr 2016
- 287.05 KB
Agilent J&W CP-Select 624 Hexane for Best Separation of Solvents and Hexane Isomers
Agilent J&W CP-Select 624 Hexane is dedicated to separate dichloromethane and hexane in India. Every column is tested and guaranteed for consistent performance.
- Application Notes
- English
- 10 Nov 2015
- 845.62 KB
- Brochures
- Data Sheets
- Flyers
- Posters
- Specifications
- Technical Overviews
- Utilities
-
- FAQs
- Firmware
- Site Preparation Checklists
- User Manuals
Videos


Agilent CrossLab Services
Agilent CrossLab is a comprehensive, coordinated method of providing services, supplies and software that dramatically improves laboratory efficiency and productivity. But even more, Agilent CrossLab is your pipeline to a global team of scientific and technical experts who deliver vital, actionable insights at every level of the lab environment.
Take advantage of Agilent CrossLab services to achieve reliable results and maximum instrument uptime, and ultimately drive improved economic, operational and scientific outcomes.
Agilent CrossLab. From Insight to Outcome
Relevant Links: