Packed GC Columns
Learn more about ordering Custom Packed Columns.
- Packed
Product Details
- UltiMetal treated stainless steel tubing promotes sharp peaks with less peak tailing for improved data accuracy
- High-efficiency packing ensures excellent reproducibility in pressure drop, flow characteristics, and separation performance resulting in less system readjustment after column installation
- Select from a range of tubing materials – including stainless steel, UltiMetal, nickel, glass, copper and PTFE (Polytetrafluoroethylene) – plus hundreds of stationary phases, packings, and supports …or you can create your own custom configurations
- Column configurations are available for all major GC brands, past and present, for worry-free compatibility
Configurations for Glass Packed GC Columns
The following configurations are available for Agilent 5880, 5890, 6890 and 7890 GC models:
Configuration A:
For 5880A, 5890A, 5890A with jet separator (all detectors except TCD), 6890 and 7890
Configuration B:
For 5890A/TCD, 5880A/TCD, 5987 GC/MS, 5988 GC/MS, 6890, and 7890
Configuration C:
For 5880A, 5890A (using liners and disposable glass inserts), 6890, and 7890
Test Conditions and Specifications for Agilent J&W Packed GC columns with standard bend configurations
- 30% DC 200/500
- CP2058, Methane, Ethane, Propane, iso-Butane, n-Butane and Pentane at 120 °C, 25 mL/min (He), Spec: asymmetry of pentane peak below 1.4
- HayeSep N
- CP1307, C1-C3 at 50 °C, Flow 10 mL/min (He), Spec: asymmetry of propane peak below 1.4
- CP2068, CO, Methane, CO2 and Ethane at 65 °C, Flow 30 mL/min (He), Spec: asymmetry of CO2 peak below or equal to 1.15
- HayeSep Q
- CP1308, C1-C3 at 50 °C, Flow 10 mL/min (He), Spec: asymmetry of propane peak below 1.4
- CP81073, Methane, Ethane, Ethylene and Acetylene at 30 °C, Flow 25 mL/min (He), Spec: asymmetry of acetylene peak below 1.4
- CP81069, Methane, Ethane, Propane, iso-Butane, n-Butane and Pentane at 130 °C, 15 mL/min (N2), Spec: asymmetry of pentane peak below 1.4
- CP1305, C1-C3 at 50 °C, Flow 10 mL/min (He), Spec: asymmetry of propane peak below 1.4
- HayeSep R
- CP86678, Methane, Ethane, Propane, iso-Butane, n-Butane and Pentane at 120 °C, 20 mL/min (He), Spec: asymmetry of pentane peak below 1.4
- CP86677, Methane, Ethane, Propane, iso-Butane, n-Butane and Pentane at 140 °C, 20 mL/min (He), Spec: asymmetry of pentane peak below 1.4
- CP2055, Methane, Ethane, Propane, iso-Butane, n-Butane, Pentane and Hexane at 225 °C, Flow 30 mL/min (He), Specs: Theoretical plates > 1000 for all compounds and retention time hexane between 6.8 and 7 min
- MolSieve 5A
- CP81025, 50 ppm CO in He at 70 °C, Flow 20 mL/min (He), Spec: asymmetry of CO peak below 1.4
- CP1306, 1% Methane in He at 50 °C, Flow 10 mL/min (He), Spec: asymmetry of methane peak below 1.4
- MolSieve 13X
- CP2059, 50 ppm CO in He at 70 °C, Flow 25 mL/min (He), Spec: asymmetry of CO peak below 1.4
- CP1309, 50 ppm CO in He at 50 °C, Flow 10 mL/min (He), Spec: asymmetry of CO peak below 1.4
- CP81071, 50 ppm CO in He at 50 °C, Flow 20 mL/min (He), Spec: asymmetry of CO peak below 1.4
Properties of Porous Polymers
Phase |
Composition |
Surface Area [m2/g] |
MAOT [ºC] |
Polarity Within Group |
Polarity Index |
Chromosorb 101 |
Styrene/divinylbenzene |
<50 |
275 |
3 |
12 |
Chromosorb 102 |
Styrene/divinylbenzene |
300-400 |
250 |
2 |
3.9 |
Chromosorb 103 |
Polystyrene (basic surface) |
15-25 |
275 |
3 |
15.6 |
Chromosorb 104 |
Acrylonitrile/divinylbenzene |
100-200 |
250 |
6 |
41.1 |
Chromosorb 105 |
Acrylic ester |
600-700 |
250 |
4 |
6.6 |
Chromosorb 106 |
Polystyrene |
700-800 |
250 |
1 |
0 |
Chromosorb 107 |
Acrylic ester |
400-500 |
250 |
9 |
14.4-18.3 |
Chromosorb 108 |
Cross linked acrylic |
100-200 |
250 |
10 |
23.4-26.2 |
HayeSep A |
Divinylbenzene/ethylene glycol dimethacrylate (high purity) |
526 |
165 |
7 |
|
HayeSep B |
Divinylbenzene/polyethyleneimine |
608 |
190 |
8 |
|
HayeSep C |
Acrylonitrile/divinylbenzene |
442 |
250 |
6 |
|
HayeSep D |
Divinylbenzene (high purity) |
795 |
290 |
1 |
|
HayeSep N |
Divinylbenzene/ethylene glycol dimethacrylate |
405 |
165 |
9 |
|
HayeSep P |
Styrene/divinylbenzene |
165 |
250 |
3 |
|
HayeSep Q |
Styrene/divinylbenzene |
582 |
275 |
2 |
|
HayeSep R |
Divinylbenzene/N-Vinyl-2-pyrolidone |
344 |
250 |
5 |
|
HayeSep S |
Divinylbenzene/4-Vinylpyridine |
583 |
250 |
4 |
|
HayeSep T |
Ethylene glycol dimethacrylate |
250 |
165 |
10 |
|
Porapak N |
N-Vinyl-2-pyrolidone |
225-350 |
190 |
9 |
10.8 |
Porapak P |
Styrene/divinylbenzene |
100-200 |
250 |
3 |
14.9 |
Porapak Q |
Styrene/ethyl vinylbenzene |
500-600 |
250 |
2 |
5.1 |
Porapak QS |
Styrene/ethyl vinylbenzene |
500-600 |
250 |
1 |
|
Porapak R |
Vinylpyrrolidone |
450-600 |
250 |
5 |
5.7 |
Porapak S |
Vinylpyridine |
300-450 |
250 |
4 |
4.5 |
Porapak T |
Ethylene glycol dimethacrylate |
250-350 |
190 |
10 |
18.3-27.7 |
Tenax GC |
Polyphenyleneoxide |
18.6 |
350 |
|
|
Tenax TA |
Polyphenyleneoxide (high purity) |
18.6 |
350 |
|
|
PoraPLOT Q (Q-HT) |
Styrene/divinylbenzene |
|
250 (290) |
|
|
PoraPLOT U |
Divinylbenzene/ethylene glycol dimethacrylate |
|
190 |
|
|
Chromosorb Properties
Increasing Inertness --> |
Chromosorb |
Chromosorb |
Chromosorb |
Chromosorb |
Chromosorb |
Max. Efficient Load |
30% |
5% |
15% |
12% |
5% |
Abs. Maximum Load |
40% |
10% |
30% |
25% |
15% |
pH |
6.5 |
8.5 |
8.5 |
8 |
- |
Maximum Temperature |
> 350 ºC |
> 350 ºC |
> 350 ºC |
> 350 ºC |
250 ºC |
Free Fall Density |
0.38 g/mL |
0.47 g/mL |
0.18 g/mL |
0.33 g/mL |
0.42 g/mL |
Packed Density |
0.47 g/mL |
0.58 g/mL |
0.24 g/mL |
0.38 g/mL |
0.49 g/mL |
- Package Inserts
-
Agilent Packed GC Column user manual
Agilent Packed GC Column user manual covering packaging, preconditioning, gas purification, optimum flow, ordering information
- Package Inserts
- English
- 09 Mar 2015
- 61.92 KB
Parts Finder Insert (Combined Version English, Japanese, Chinese)
Find your ideal match of Agilent GC Columns and Supplies with the Agilent Parts Finder tool and the GC Column Selection Tool.
- Package Inserts
- English
- 27 Jun 2013
- 2.72 MB
Find your ideal match: GC Tools promotion insert
Find your ideal match of Agilent GC Columns and Supplies with the Agilent Parts Finder tool and the GC Column Selection Tool.
- Package Inserts
- English
- 27 Jun 2013
- 1.12 MB
Save time - use our GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
The GC Pressure/Flow Calculator Software helps you to determine pressure settings and flow rates through a capillary GC column and calculates the vapor volume for a liquid solvent vaporized in a heated GC inlet.
GC Pressure/Flow Calculator Application for iPhone
GC Pressure/Flow Calculator Software for PC: Revision 2.05
Agilent CrossLab is a growing portfolio of GC and HPLC supplies critical to instrument performance and productivity. They are manufactured to perform seamlessly with a variety of analytical instruments in your lab - including Bruker/Varian, PerkinElmer, Thermo/Dionex and Shimadzu.
CrossLab supplies deliver the same commitment to quality inherent in all Agilent products – all with our risk-free, 90-day, money-back guarantee.
Find the right products using our cross-reference, easy-to-use online selection tool.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials