大气压化学电离离子源 (APCI)
安捷伦 APCI 离子源灵敏度高,而且非常耐用,这主要归功于直角雾化和反吹干燥气。与 ESI 离子源相似,它可以生成正离子和负离子,且离子极性可在谱图之间切换。
- LC/MS Ion Sources
Request a Quote
Product Details
- 电喷雾电离的补充技术
- 适用于广泛的化合物,包括低极性和非极性分子
- 主要生成单电荷离子,运行温度更高
- 响应随总质量流量的增加而增加,因此对于较大的色谱柱和更高的液相色谱流速,性能可得到很好的扩展
- Application Notes
-
Screening and Confirmation of Anabolic Steroids Using Accurate Mass LC/MS
The use of the Agilent LC/MSD TOF, an orthogonal-axis time-of-flight (oa-TOF) mass spectrometer, equipped with an atmospheric pressure chemical ionization...
- Application Notes
- English
- 11 Jan 2017
- 317.79 KB
Analysis of Polymer Antioxidant Additives on the Agilent 500 Ion Trap LC/MS
Plastics are widely used and they vary in their application, ranging from automobile parts, components for houses and buildings, and packaging for everything from food to...
- Application Notes
- English
- 04 Feb 2014
- 1.31 MB
Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source
Application note for the analysis of cannabinoids and amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source
- Application Notes
- English
- 20 Jan 2014
- 125.31 KB
Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS
Application note for the analysis of aatural food colorants by electrospray and Atmospheric Pressure Chemical Ionization LC/MS
- Application Notes
- English
- 16 Jan 2014
- 403.94 KB
The Analysis of Triglycerides in Edible Oils by APCI LC/MS
Application note for the analysis of triglycerides in edible oils by APCI LC/MS
- Application Notes
- English
- 16 Jan 2014
- 291.33 KB
Development of an LC/MS Method for the Analysis of Rodenticides
Application note for the development of an LC/MS method for the analysis of rodenticides
- Application Notes
- English
- 15 Jan 2014
- 162.70 KB
Improved and Simplified Liquid Chromatography/Atmospheric Pressure Chemical Ionization Mass Spectrometry Method for the Analysis of Underivatized Free Amino Acids in Various Foods
Application note for the analysis of underivatized free amino acids in various foods
- Application Notes
- English
- 14 Jan 2014
- 112.91 KB
Screening of Corticosteroids in Urine by Positive Atmospheric Pressure Chemical Ionization LC/MS/MS
Detailing the screening of corticosteroids in urine by positive atmospheric pressure chemical ionization LC/MS/MS.
- Application Notes
- English
- 15 Apr 2013
- 388.34 KB
- Technical Overviews