Bond Elut EMR-Lipid
Bond Elut Enhanced Matrix Removal - Lipid provides the most comprehensive matrix removal of any sample preparation product. Lipids can be extracted selectively from high-fat samples without analyte loss. The final polishing step removes excess water and improves analyte partitioning.
These QuEChERS kits contain 1 g of preweighed sorbent in 15 mL centrifuge tubes. They can easily accommodate the aliquot volumes specified by current AOAC and EN methodologies.
These QuEChERS kits contain 1 g of preweighed sorbent in 15 mL centrifuge tubes. They can easily accommodate the aliquot volumes specified by current AOAC and EN methodologies.
- QuEChERS Kits & Standards for Sample Preparation
This product is not available for purchase by the general public.
Product Details
Features
- Proprietary lipid removing sorbent, 15mL centrifuge tube, 50/pack
- Innovative sorbent targets lipid removal while retaining analytes of interest
- Higher sensitivity and more reproducible results by removing interfering matrix components
- Reduced matrix contributions from samples results in a cleaner, more reliable MS source
- Cleaner sample profiles reduce error and speed up data processing for higher throughput
- Save time and resources with less troubleshooting and sample-related instrument maintenance
Tools
QuEChERS Selector Tool
QuEChERS eSelector provides extraction and dispersive kit recommendations for pesticides in fruit and vegetables.
How It Works
Videos
Literature
- Key Literature
-
Multiresidue Analysis of Pesticides in Avocado with Bond Elut EMR-Lipid by LC/MS/MS
EMR-Lipid removes high-fat avocado matrix effectively, with better recovery, speed, robustness, cleanliness, excellent accuracy and precision of pesticides.
- Application Notes
- English
- 26 Aug 2015
- 304.02 KB
PAH Analysis in Salmon with Enhanced Matrix Removal
Agilent Bond Elut Enhanced Matrix Removal-Lipid quantitates low to high PAH concentrations in salmon with a simple QuEChERS workflow that minimizes fat coextracts.
- Application Notes
- English
- 31 Aug 2015
- 214.53 KB
Benefits of EMR-Lipid Cleanup with Enhanced Post Treatment on Pesticides Analysis by GC/MS/MS
This study investigates the modified EMR-Lipid protocol for the analysis of pesticides in avocado by GC/MS/MS.
- Application Notes
- English
- 20 Apr 2016
- 882.71 KB
- Application Notes
Featured References
- Publications
-
- Álvarez-Ruiz, R.; Picó, Y.; Sadutto, D.; Campo, J. Development of Multi-Residue Extraction Procedures Using QuEChERS and Liquid Chromatography–Tandem Mass Spectrometry for the Determination of Different Types of Organic Pollutants in Mussels. Analytical and Bioanalytical Chemistry 2021. https://doi.org/10.1007/s00216-021-03363-y
- Stöckelhuber, M.; Müller, C.; Vetter, F.; Mingo, V.; Lötters, S.; et al. Determination of Pesticides Adsorbed on Arthropods and Gastropods by a Micro-QuEChERS Approach and GC–MS/MS. Chromatographia 2017. https://doi.org/10.1007/s10337-017-3280-8
Related Products
Promotions