1260 Infinity II Vialsampler Ordering Details
Place an order or get more detailed ordering information including prices and availability, , contact your local Agilent sales office or distributor or Request a Quote.
Description | Part Number |
1260 Infinity II Vialsampler
UHPLC design autosampler up to 800 bar for 0.1 to 100 µL injections. Standard needle flush port and peristaltic pump. Default setup with 100 µL loop and 100 µL analytical head. |
G7129C |
Drawer choice 6x 11 vials (2 mL), 2 drawers included | G7129C #010 |
Drawer choice 3x 6 vials (6 mL), 2 drawers included | G7129C #011 |
Drawer choice 5x 10 vials (2 mL), 2 drawers included | G7129C #012 |
Extended Injection Range Option
900 µL analytical head and sample loop for large single-stroke injections (400 bar pressure limit) |
G7129C#020 |
Sample Cooler
Cooling unit to fit G7167A/B samplers as well as G7129 A/B/C samplers. Slide-in unit, customer installable. |
G7129C #100 |
Integrated Column Compartment
Integrated column compartment for up to two columns with 3 µL heater volume, for standard analytical flow rates up to 5 mL/min. Recommended for lowest dispersion and filtered samples |
G7129C #063 |
Integrated Column Compartment
Integrated column compartment for up to two columns with 6 µL heater volume, for standard analytical flow rates up to 5 mL/min Recommended for robust routine |
G7129C #066 |
2 mL Vial Drawer (6x11 positions)
Each drawer can hold 66x 2 mL vials. Samples are set up in an A1 to F11 format (microtiter-plate style). 2 drawers/pack. |
G7129C #010 |
6 mL Vial Drawer (3x6 positions)
Each drawer can hold 18 x 6 mL vials. Samples are set up in an A1 to C6 format (microtiter-plate style). 2 drawers/pack. |
G7129C #011 |
Classic Drawer Kit (10x10 positions split in 2 drawers)
Kit of 2 drawers to hold 100x 2 mL vials. Samples are set up in a 1 to 100 format (classic Agilent vial sampler style). |
G7129C #012 |
Analytical Head 40 µL
40 µL analytical head, 600 bar pressure limit. |
G7129C #162 |
Sample Loop 40 µL
Sample loop 40 µL, for maximum 40 µL injection, 800 bar pressure limit. |
G7129C #150 |
Sample Loop 20 µL
Sample loop 20 µL for maximum 20 µL injection, 800 bar pressure limit. |
G7129C #148 |
Multidraw Option Adding 400 µL/1400 µL
Includes two seat capillary extensions to inject up to 500 or up to 1,500 µL volume. |
G7129C #021 |
Walkup Extension: External Tray
External tray offering 5 vial positions (2 mL) and 1 vial disposal position. |
G7129-60000 |
Walkup Extension: Vial Disposal Tube
Disposal tube to fit on vial disposal position. |
G1313-27302 |
Description | Part Number |
1260 Infinity II Vialsampler
UHPLC design autosampler up to 600 bar for 0.1 to 100 µL injections.. Standard needle flush port and peristaltic pump. Default setup with 100 µL loop and 100 µL analytical head. |
G7129A |
Drawer choice 6x 11 vials (2 mL), 2 drawers included | G7129A #010 |
Drawer choice 3x 6 vials (6 mL), 2 drawers included | G7129A #011 |
Drawer choice 5x 10 vials (2 mL), 2 drawers included | G7129A #012 |
Extended Injection Range Option
900 µL analytical head and sample loop for large single-stroke injections (400 bar pressure limit) |
G7129A #020 |
Sample Cooler
Cooling unit to fit G7167A/B samplers as well as G7129 A/B samplers. Slide-in unit, customer installable. |
G7129A #100 |
Integrated Column Compartment
Integrated column compartment for up to two columns with 3 µL heater volume, for standard analytical flow rates up to 5 mL/min. Recommended for lowest dispersion and filtered samples |
G7129A #063 |
Integrated Column Compartment
Integrated column compartment for up to two columns with 6 µL heater volume, for standard analytical flow rates up to 5 mL/min Recommended for robust routine |
G7129A #066 |
2 mL Vial Drawer (6x11 positions)
Each drawer can hold 66x 2 mL vials. Samples are set up in an A1 to F11 format (microtiter-plate style). 2 drawers/pack. |
G7129A #010 |
6 mL Vial Drawer (3x6 positions)
Each drawer can hold 18x 6 mL vials. Samples are set up in an A1 to C6 format (microtiter-plate style). 2 drawers/pack. |
G7129A #011 |
Classic Drawer kit (10x10 positions split in 2 drawers)
Kit of 2 drawers to hold 100x 2 mL vials. Samples are set up in a 1 to 100 format (classic Agilent vial sampler style). |
G7129A #012 |
Analytical Head 40 µL
40 µL analytical head, 600 bar pressure limit. |
G7129A #162 |
Sample Loop 40 µL
Sample loop 40 µL, for maximum 40 µL injection, 600 bar pressure limit. |
G7129A #150 |
Sample Loop 20 µL
Sample loop 20 µL for maximum 20 µL injection, 600 bar pressure limit. |
G7129A #148 |
Multidraw Option Adding 400 µL/1400 µL
Includes two seat capillary extensions to inject up to 500 or up to 1,500 µL volume. |
G7129A #021 |
Walkup Extension: External Tray
External tray offering 5 vial positions (2 mL) and 1 vial disposal position. |
G7129-60000 |
Walkup Extension: Vial Disposal Tube
Disposal tube to fit on vial disposal position. |
G1313-27302 |