Agilent 7800 ICP-MS
7800 ICP-MS
The 7800 ICP-MS is the ideal choice for reliable analysis of complex, variable, high matrix samples, whist also offering high performance for research applications. The 7800 ICP-MS combines performance, ease of use and reliability in a workhorse system that is equally at home in commercial and research laboratories.
- ICP-MS Systems
Product Details
- Fast track your routine metals analysis – ICP-MS MassHunter software includes Pre-Set Methods that can be simply loaded and run with predefined setting, from plasma conditions to analyte integration time and internal standards. For new methods, the Method Wizards builds the method based on sample type and application.Learn more about our drinking water, environmental waste and elemental impurities in pharmaceutical product solutions, below.
- Reduce sample preparation – Unique High Matrix Introduction (HMI) technology, standard on the 7800 ICP-MS, lets you analyze samples containing up to 3% total dissolved solids (TDS) without dilution, reducing sample preparation and saving time.
- Minimize signal suppression – HMI reduces signal suppression, so high matrix samples can be measured accurately without requiring matrix matched calibration standards.
- Ensure accurate data with effective interference removal – Helium (He) collision mode simplifies method development and routine operation by removing polyatomic ion interferences under a single consistent set of conditions. He mode avoids the need for matrix or analyte-specific reaction cell conditions.
- Analyze major and trace analytes in a single run – The wide dynamic range orthogonal detector system (ODS) enables direct analysis of major elements (100s or 1000s of ppm) and trace level analytes (single or sub-ppt) in a single run. The high upper concentration limit reduces sample reruns caused by overrange results.
- Maximize throughput and productivity – The optional Integrated Sample Introduction System (ISIS 3) and the SPS 4 Autosampler lower your cost per analysis without compromising data quality
Nanoparticles Analysis by ICP-MS
The use of nanomaterials – as anti-bacterial agents in consumer products and healthcare, food additives, sunscreen and cosmetics, life science research, drug delivery and bioimaging, catalysts and coatings, electronics, optics and materials technology – has increased the concentration of these silica, metallic and organic based materials in the environment. The limited understanding regarding nanoparticle fate and impact in the environment has driven some countries to ban their use. Characterizing nanoparticle concentrations, distribution environmental impact require requires detection, quantitation and single particle characterization in complex matrices. Agilent’s solution for ICP/MS – Model 7900 ICP/MS and 8800 Triple Quadrupole ICP/MS – Agilent’s solutions provide researchers with powerful, fast and cost effective tools that facilitate NP characterization, and quantitative analysis.
Soil Metals Analysis by ICP-MS
Regulatory bodies have a duty to protect the public from exposure to hazardous substances, including potentially toxic heavy metals and other inorganic and organometallic species present in soil. Agilent ICP-MS instruments are ideal for monitoring these substances—whether naturally occurring or the result of industrial or agricultural activity—because they can provide robust performance and precise quantitative analysis of trace level inorganics.
- Key Literature
-
Solution-ready Agilent 7800 ICP-MS
Fast-track your metals analysis with solution-ready Agilent 7800 ICP-MS
- Brochures
- English
- 01 Aug 2019
- 1.18 MB
Fast-track your metals analysis with the Agilent 7800 ICP-MS
General metals analysis with the solution-ready Agilent 7800 ICP-MS
- Flyers
- English
- 28 May 2015
- 1.42 MB
Fast-track your environmental waste analysis with the Agilent 7800 ICP-MS
Waste analysis with the solution-ready Agilent 7800 Quadrupole ICP-MS
- Flyers
- English
- 29 May 2015
- 1.46 MB
Fast-track your drinking water analysis with the Agilent 7800 ICP-MS
Drinking water analysis with the solution-ready Agilent 7800 Quadrupole ICP-MS
- Flyers
- English
- 28 May 2015
- 1.44 MB
Fast-track your pharmaceutical analysis with the Agilent 7800 ICP-MS
Elemental Impurity analysis solution-ready Agilent 7800 Quadrupole ICP-MS
- Flyers
- English
- 28 May 2015
- 1.37 MB
Enhancing the productivity of food sample analysis with ICP-MS
ICP-MS method for measuring both major and trace elements in food samples in a single analytical run.
- Application Notes
- English
- 14 Jul 2017
- 420.35 KB
Analysis of flue gas desulfurization wastewaters by Agilent 7700x/7800 ICP-MS
Application note for the analysis of flue gas desulfurization wastewaters by Agilent 7700x/7800 ICP-MS
- Application Notes
- English
- 21 Sep 2015
- 251.61 KB
Validating the Agilent 7700x/7800 ICP-MS for the determination of elemental impurities in pharmaceutical ingredients according to draft USP general chapters <232>/<233>
Application note for validating the Agilent 7700x/7800 ICP-MS for the determination of elemental impurities in pharmaceutical ingredients
- Application Notes
- English
- 01 Jun 2015
- 421.42 KB
Using Qualifier Ions to Improve ICP-MS Data Quality for Waste Water Analysis
An effective method for validating high throughput multi-element data from high matrix waste water samples
- Application Notes
- English
- 27 Jul 2015
- 1.63 MB
Simple, Reliable Analysis of High Matrix Samples According to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS
Application note for Simple, Reliable Analysis of High Matrix Samples According to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS
- Application Notes
- English
- 22 Sep 2015
- 642.96 KB
Atomic Spectroscopy Portfolio Brochure
An overview of Agilent's atomic spectroscopy portfolio, including AAS, MP-AES, ICP-AES, ICP-MS and ICP-QQQ.
- Brochures
- English
- 26 Jul 2017
- 2.08 MB
Accurate, Reliable, Cost-Effective Metals Analysis For Environmental Samples
Discover Agilent’s range of instruments for the elemental analysis of environmental samples.
- Flyers
- English
- 08 Dec 2016
- 713.61 KB
Successful low level mercury analysis with the 7800 ICP-MS
Learn how you can successfully overcome the challenges of Hg analysis with the 7800 ICP-MS
- Flyers
- English
- 31 May 2015
- 1.42 MB
ORS4 and helium mode for more effective inteference removal in complex samples
Learn about the benefits of helium mode used in the 7800 ICP-MS.
- Flyers
- English
- 31 May 2015
- 1.92 MB
Plasma Robustness in ICP-MS - Benefits of a low CeO/Ce ratio
Learn how the 7800 ICP-MS, with HMI, can measure very high and variable matrix samples accurately, without matrix-matched calibration standards.
- Flyers
- English
- 31 May 2015
- 1019.83 KB
ICP-MS Journal, July 2015, Issue 62
ICP-MS journal covering the new Agilent 7800 ICP-MS, applications, upcoming webinars, meetings and seminars
- Newsletters
- English
- 19 Jul 2015
- 3.81 MB
Atomic Spectroscopy Applications in the Contract Environmental Labs
Agilent Atomic Spectroscopy Solutions for the analysis of drinking water, waste water, soils and sludges
- Primers
- English
- 22 Aug 2016
- 6.54 MB
7800/7900 ICP-MS Site Preparation Checklist (Japanese)
7800/7900 ICP-MS Site Preparation Checklist (Japanese)
- Site Preparation Checklists
- Japanese
- 09 Jun 2015
- 1.69 MB
- Application Notes
- Brochures
- Flyers
- Newsletters
- Posters
- Primers
- Reference Data
- Technical Overviews
- White Papers