Skip to main content

GC Columns Cross-reference Guide - Supelco

If you are using a Supelco GC column and would like to upgrade to an Agilent J&W column, this GC column cross-reference guide will make your conversion easy. Each section of this guide lists, by phase selection, the suggested Agilent J&W upgrade from Supelco's columns. This is not, however, a complete listing, but represents only the most frequently used columns. If you have further questions, please contact us.

Tip: To find the Agilent upgrade for the Supelco phase or part number you are currently using, select the "Find" function from your internet browser "Edit" menu.

Supelco Phase

Supelco P/N

Length (m)

ID (mm)

Film (µm)

Agilent J&W Equivalent

Agilent J&W P/N

Notes

b-DEX 110

24301

30

0.25

0.25

Cyclodex-B

112-2532

Same chiral selector embedded in a cyanopropylphenyl phase

b-DEX 110

24302

60

0.25

0.25

Cyclodex-B

112-2562

Same chiral selector embedded in a cyanopropylphenyl phase

b-DEX 120

24304

30

0.25

0.25

HP-Chiral 20B

19091G-B233


b-DEX 325

24308

30

0.25

0.25

CycloSil-B

112-6632

Same chiral selector embedded in a cyanopropylphenyl phase

Carbowax Amine

25352

15

0.53

1

CAM

115-2112


Carbowax Amine

25353

30

0.53

1

CAM

115-2132


Carbowax Amine

25354

60

0.53

1

CAM

115-2162


Carboxen-1006 PLOT

25461

30

0.53

NA

GS-CarbonPLOT

115-3133


Carboxen-1006 PLOT

24241-U

30

0.32

NA

GS-CarbonPLOT

113-3132


Carboxen-1010 PLOT

24246

30

0.32

NA

GS-CarbonPLOT

113-3132


Carboxen-1010 PLOT

25467

30

0.53

NA

GS-CarbonPLOT

115-3133


Deactivated Guard Column for OVI-G43

25339

5

0.53

N/A

Deactivated F.S. Tubing

160-2535-5


HT-5

25002

12

0.32

0.1

DB-5ht

123-5711

Slightly different dimensions

HT-5

25003

25

0.32

0.1

DB-5ht

123-5731

Slightly different dimensions

MDN-1

24258

30

0.25

0.25

DB-1ms

122-0132


MDN-1

24259

30

0.25

1

DB-1

122-1033


MDN-1

24299

30

0.32

0.25

DB-1ms

123-0132


MDN-1

24300-U

30

0.32

1

DB-1

123-1033


MDN-5

24096

30

0.25

0.25

DB-5

122-5032


HP-5

19091J-433

MDN-5

24097

30

0.32

0.25

DB-5

123-5032


HP-5

19091J-413

MDN-5

24203

30

0.32

0.32

DB-5

100-2000


HP-5

100-2000

MDN-5

24204-U

30

0.32

1

DB-5

123-5033


HP-5

19091J-213

MDN-5S

24378

30

0.25

0.1

DB-5ms

122-5531


MDN-5S

24377-U

15

0.25

0.25

DB-5ms

122-5512


MDN-5S

24384

30

0.25

0.25

DB-5ms

122-5532


MDN-5S

24392

60

0.25

0.25

DB-5ms

122-5562


MDN-5S

24379

30

0.25

0.5

DB-5ms

122-5536


MDN-5S

24385-U

30

0.25

1

DB-5ms

122-5533


MDN-5S

24386

30

0.32

0.25

DB-5ms

122-5532


MDN-5S

24394

60

0.32

0.25

DB-5ms

123-5562


MDN-5S

24393

30

0.32

0.5

DB-5ms

122-5536


MDN-5S

24387-U

30

0.32

1

DB-5ms

123-5533


MDN-5S

25474

30

0.53

1.5

DB-5ms

125-5532


MDN-12

24388

30

0.25

0.25

DB-XLB

122-1232


MDN-12

24396

60

0.25

0.25

DB-XLB

122-1262


MDN-12

24395

30

0.25

0.5

DB-XLB

122-1236


MDN-12

24389

30

0.25

1

DB-XLB

122-1233


MDN-12

24390-U

30

0.32

0.25

DB-XLB

123-1232


MDN-12

24398

60

0.32

0.25

DB-XLB

123-1262


MDN-12

24397

30

0.32

0.5

DB-XLB

123-1236


MDN-12

24391

30

0.32

1

DB-XLB

123-1233


MDN-35

24382-U

30

0.25

0.25

DB-35ms

122-3832


MDN-35

24383-U

30

0.32

0.25

DB-35ms

123-3832


MET-1

25473

15

0.53

1.5

DB-PS1

145-1012


MET-1

25477

30

0.53

0.5

DB-PS1

145-1037


MET-1

25478

30

0.53

3

DB-PS1

145-1034


MET-1

25487

15

0.53

0.5

DB-PS1

145-1017


MET-1

25488

30

0.53

1.5

DB-PS1

145-1032


MET-1

25489

30

0.53

5

DB-PS1

145-1035


MET-5

25482

30

0.53

1.5

DB-PS5

145-5032


MET-WAX

25484

15

0.53

1

DB-PSWAX

145-7012


MET-WAX

25485

30

0.53

1

DB-PSWAX

145-7032


Mol Sieve 5A PLOT

24243

30

0.32

NA

HP-PLOT MoleSieve

19091P-MS4


Mol Sieve 5A PLOT

25463

30

0.53

NA

HP-PLOT MoleSieve

19095P-MS6


NUKOL

24107

30

0.25

0.25

DB-FFAP

122-3232


HP-FFAP

19091F-433

NUKOL

24108

60

0.25

0.25

DB-FFAP

122-3262


NUKOL

24130

15

0.32

0.25

DB-FFAP

123-3212


HP-FFAP

19091F-411

NUKOL

24131

30

0.32

0.25

DB-FFAP

123-3232


HP-FFAP

19091F-413

NUKOL

24132

60

0.32

0.25

DB-FFAP

123-3262


NUKOL

24207

30

0.32

1

DB-FFAP

123-3234


NUKOL

24208

60

0.32

1

DB-FFAP

123-3264


NUKOL

25326

15

0.53

0.5

DB-FFAP

125-3217


NUKOL

25327

30

0.53

0.5

DB-FFAP

125-3237


NUKOL

25386

60

0.53

0.5

DB-FFAP

100-2000


NUKOL

24106-U

15

0.25

0.25

DB-FFAP

122-3212


HP-FFAP

19091F-431

NUKOL

24206-U

15

0.32

1

DB-FFAP

123-3214


Omegawax 250

24136

30

0.25

0.25

DB-WAXetr

122-7332 19091N-133


HP-INNOWax

Omegawax 320

24152

30

0.32

0.25

DB-WAXetr

123-7332 19091N-113


HP-INNOWax

Omegawax 530

25374

30

0.53

0.5

DB-WAXetr

100-2000


Petrocol DH 50.2

24133-U

50

0.20

0.5

DB-Petro50

128-1056


HP-PONA

19091S-001

Petrocol DH

24160-U

100

0.25

0.5

DB-Petro100

122-10A6 19091Z-530


HP-1

Petrocol 2887

25323

5

0.53

0.5

DB-HTSimDis

145-1001


PTA-5

24277

30

0.25

0.5

DB-5

122-503E


PTA-5

24330

30

0.25

1

DB-5

122-5033


PTA-5

24331

30

0.32

0.50

DB-5

123-503E


PTA-5

24332

30

0.32

1

DB-5

123-5033


PTA-5

24333

30

0.32

1.5

DB-5

123-503B


PTA-5

25437

30

0.53

0.5

DB-5

125-5037


PTA-5

25438

30

0.53

1.5

DB-5

125-5032


PTA-5

25439

30

0.53

3

DB-5

125-5034


PTE-5

24135-U

30

0.25

0.25

DB-5ms

122-5532 19091S-433


HP-5ms

PTE-5

24143

30

0.32

0.25

DB-5ms

123-5532 19091S-413


HP-5ms

PTE-5

24159

30

0.32

1

DB-5ms

123-5533 19091S-213


HP-5ms

PTE-5QTM

25355

15

0.53

0.5

DB-5ms

125-5017


SE-30

24004-U

30

0.25

0.25

SE30

112-3032


SE-54

24001

30

0.25

0.25

SE-54

112-5432


SP-2250

24009

15

0.25

0.2

DB-17

122-1712

Bonded phase instead of non-bonded. 0.25um instead of 0.20um

HP-50+

19091L-431

SP-2250

24010

30

0.25

0.2

DB-17

122-1732

Bonded phase instead of non-bonded. 0.25um instead of 0.20um

HP-50+

19091L-433

SP-2250

24011-U

60

0.25

0.2

DB-17

122-1762

Bonded phase instead of non-bonded. 0.25um instead of 0.20um

HP-50+

19091L-436

SP-2250

24147

15

0.32

0.2

DB-17

123-1712

Bonded phase instead of non-bonded. 0.25um instead of 0.20um

HP-50+

19091L-411

SP-2250

24148

30

0.32

0.2

DB-17

122-1732

Bonded phase instead of non-bonded. 0.25um instead of 0.20um

HP-50+

19091L-413

SP-2331

24257

30

0.25

0.2

DB-Dioxin

100-2000


SP-2331

24104-U

60

0.25

0.2

DB-Dioxin

122-2462


SP-2331

24105

60

0.32

0.2

DB-Dioxin

123-2461


SPB-608

24103-U

30

0.25

0.25

DB-608

122-6832


SPB-608

25312

30

0.53

0.5

DB-608

125-6837


SPB-624

24255

30

0.25

1.4

DB-624

122-1334


SPB-624

24256

60

0.25

1.4

DB-624

122-1364


SPB-624

24251

60

0.32

1.8

DB-624

123-1364


SPB-624

25430

30

0.53

3

DB-624

125-1334


SPB-624

25432

75

0.53

3

DB-624

125-1374


SPB-HAP

25020-U

60

0.32

4

DB-1

100-2000


SAC-5

24151

15

0.25

0.25

DB-5ms

122-5512 19091S-431


HP-5ms

SAC-5

24156

30

0.25

0.25

DB-5ms

122-5532 19091S-433


HP-5ms

SPB-1 Sulfur

24158

30

0.32

4

HP-1

19091Z-613


OVI-G43

25396

30

0.53

3

DB-624

125-1334


SPB-5

25339

30

0.53

5

DB-5

125-5035 19095J-623


HP-5

SPB-1

25360

15

0.53

0.1

DB-1

125-1011

Slightly different dimensions

SPB-1

24338

15

0.1

0.1

DB-1

127-1022

Slightly different dimensions

SPB-1

24162

15

0.2

0.2

DB-1

128-10H7


SPB-1

24299-U

12

0.2

0.33

DB-1

128-1012 19091-60312


HP-1

SPB-1

24230-U

25

0.2

0.33

DB-1

128-1022


HP-1

19091Z-331

SPB-1

24261

30

0.25

0.1

DB-1

122-1031 19091Z-333


HP-1

SPB-1

24026

15

0.25

0.25

DB-1

122-1012 19091Z-431


HP-1

SPB-1

24028

30

0.25

0.25

DB-1

122-1032 19091Z-433


HP-1

SPB-1

24030-U

60

0.25

0.25

DB-1

122-1062 19091Z-436


HP-1

SPB-1

24198

100

0.25

0.25

DB-1

100-2000


SPB-1

24027

15

0.25

1

DB-1

122-1013 19091Z-231


HP-1

SPB-1

24029

30

0.25

1

DB-1

122-1033 19091Z-233


HP-1

SPB-1

24031

60

0.25

1

DB-1

122-1063 19091Z-236


HP-1

SPB-1

24220-U

100

0.25

1.00

DB-1

100-2000


SPB-1

24290

30

0.32

0.1

DB-1

123-1031 19091Z-313


HP-1

SPB-1

24099

15

0.32

0.25

DB-1

123-1012 19091Z-411


HP-1

SPB-1

24044

30

0.32

0.25

DB-1

123-1032 19091Z-413


HP-1

SPB-1

24046

60

0.32

0.25

DB-1

123-1062 19091Z-416


HP-1

SPB-1

24228-U

100

0.32

0.25

DB-1

100-2000


SPB-1

24098-U

15

0.32

1

DB-1

123-1013 19091Z-211


HP-1

SPB-1

24045-U

30

0.32

1

DB-1

123-1033 19091Z-213


HP-1

SPB-1

24047

60

0.32

1

DB-1

123-1063 19091Z-216


HP-1

SPB-1

24213-U

100

0.32

1.00

DB-1

100-2000


SPB-1

24215-U

30

0.32

2

DB-1

123-103G


SPB-1

24216-U

60

0.32

2

DB-1

123-106G


SPB-1

24296

30

0.32

5

DB-1

123-1035 19091Z-713


HP-1

SPB-1

24297

60

0.32

5.00

DB-1

123-1065 19091Z-716


HP-1

SPB-1

25361

30

0.53

0.1

DB-1

125-1039


SPB-1

25314

15

0.53

0.2

DB-1

100-2000


SPB-1

25315

30

0.53

0.20

DB-1

100-2000


SPB-1

25382

60

0.53

0.2

DB-1

100-2000


SPB-1

25416

15

0.53

1

DB-1

125-101J


SPB-1

25417

30

0.53

1

DB-1

125-103J


SPB-1

25302-U

15

0.53

1.5

DB-1

125-1012 19095Z-321


HP-1

SPB-1

25303

30

0.53

1.50

DB-1

125-1032 19095Z-323


HP-1

SPB-1

25388

60

0.53

1.5

DB-1

125-1062


SPB-1

25340

15

0.53

3

DB-1

125-1014 19095Z-421


HP-1

SPB-1

25341-U

30

0.53

3

DB-1

125-1034 19095Z-423


HP-1

SPB-1

25348

60

0.53

3

DB-1

125-1064


SPB-1

25344

15

0.53

5

DB-1

125-1015 19095Z-621


HP-1

SPB-1

25345-U

30

0.53

5

DB-1

125-1035 19095Z-623


HP-1

SPB-1

25349

60

0.53

5

DB-1

125-1065 19095Z-626


HP-1

SPB-5

24165-U

15

0.2

0.2

DB-5

128-50H7


SPB-5

24166

30

0.2

0.2

DB-5

100-2000


SPB-5


12

0.2

0.33

DB-5

128-5012 19091J-101


HP-5

SPB-5

24032

15

0.25

0.25

DB-5

122-5012 19091J-431


HP-5

SPB-5

24034

30

0.25

0.25

DB-5

122-5032 19091J-433


HP-5

SPB-5

24036

60

0.25

0.25

DB-5

122-5062 19091J-436


HP-5

SPB-5

24033

15

0.25

1

DB-5

122-5013 19091J-231


HP-5

SPB-5

24035

30

0.25

1

DB-5

122-5033 19091J-233


HP-5

SPB-5

24037

60

0.25

1

DB-5

122-5063 19091J-236


HP-5

SPB-5


15

0.32

0.25

DB-5

123-5012 19091J-411


HP-5

SPB-5

24048

30

0.32

0.25

DB-5

123-5032 19091J-413


HP-5

SPB-5

24050

60

0.32

0.25

DB-5

122-5062 19091J-416


HP-5

SPB-5

24360

30

0.32

0.5

DB-5

123-503E 19091J-113


HP-5

SPB-5


15

0.32

1

DB-5

123-5013 19091J-211


HP-5

SPB-5

24049

30

0.32

1.00

DB-5

123-5032 19091J-213


HP-5

SPB-5

24051

60

0.32

1

DB-5

123-5063 19091J-216


HP-5

SPB-5

25304

15

0.53

1.5

DB-5

125-5012 19095J-321


HP-5

SPB-5

25316

15

0.53

0.5

DB-5

125-5017


SPB-5

25317

30

0.53

0.5

DB-5

125-5037


SPB-5

24341

15

0.1

0.1

DB-5

127-5022

Slightly different dimensions

SPB-5

25342

15

0.53

3

DB-5

100-2000


SPB-5

25343

30

0.53

3

DB-5

125-5034


SPB-5

25346

15

0.53

5

DB-5

125-5015 19095J-621


HP-5

SPB-5

25347

30

0.53

5

DB-5

125-5035 19095J-623


HP-5

SPB-5

25350

60

0.53

3

DB-5

100-2000


SPB-5

25351

60

0.53

5

DB-5

125-5065


SPB-5

25383

60

0.53

0.5

DB-5

100-2000


SPB-5


30

0.53

1

DB-5

125-503J


SPB-5


30

0.53

1.5

DB-5

125-5032 19095J-323


HP-5

SPB-5

25389

60

0.53

1.5

DB-5

125-5062


SPB-17

24376

30

0.32

0.5

DB-17

123-1733


HP-50+

19091L-113

SPB-17

24381

30

0.32

0.25

DB-17

123-1732


HP-50+

19091L-413

SPB-17

25472

15

0.53

1

DB-17

125-1712


HP-50+

19095L-021

SPB-17

24374-U

15

0.25

0.25

DB-17

122-1712


HP-50+

19091L-431

SPB-17

24380-U

30

0.25

0.25

DB-17

122-1732


HP-50+

19091L-433

SPB-35

24092

30

0.25

0.25

DB-35

122-1932 19091G-133


HP-35

SPB-35

24094

30

0.32

0.25

DB-35

123-1932 19091G-113


HP-35

SPB-35

25331

30

0.53

0.5

DB-35

125-1937 19095G-523


HP-35

SPB-35

25335

30

0.53

1.00

DB-35

125-1932 19095G-123


HP-35

SPB-50

24181

30

0.25

0.25

DB-17

122-1732 19091L-433


HP-50+

SPB-50

24187

30

0.32

0.25

DB-17

123-1732 19091L-413


HP-50+

SPB-50

25363

30

0.53

0.50

DB-17

125-1737 19095L-523


HP-50+

SPB-225

24334

30

0.25

0.15

DB-225

122-2231


SPB-225

24335

30

0.25

0.25

DB-225

122-2232


SPB-225

24336

30

0.32

0.15

DB-225

123-2231


SPB-225

24337

30

32

0.25

DB-225

123-2232


SPB-1000

24313

30

0.25

0.25

DB-FFAP

122-3232


HP-FFAP

19091F-433

SPB-1000

24315

30

0.32

0.25

DB-FFAP

123-3232


HP-FFAP

19091F-413

SPB-1000

25445

30

0.53

0.5

DB-FFAP

125-3237


SPB-1701

24112

15

0.25

0.25

DB-1701

122-0712


SPB-1701

24113

30

0.25

0.25

DB-1701

122-0732


SPB-1701

24114

60

0.25

0.25

DB-1701

122-0762


SPB-1701

24183

15

0.32

0.25

DB-1701

123-0712


SPB-1701

24184

30

0.32

0.25

DB-1701

123-0732


SPB-1701

24185

60

0.32

0.25

DB-1701

123-0762


SPB-1701

25368

15

0.53

0.5

DB-1701

125-0717


SPB-1701

25369

30

0.53

0.5

DB-1701

125-0737


SPB-1701

25366

15

0.53

1

DB-1701

125-0712


SPB-1701

25367

30

0.53

1

DB-1701

125-0732


SUPELCOWAX 10

24077

15

0.25

0.25

DB-WAXetr

122-7312 19091N-131


HP-INNOWax

SUPELCOWAX 10

24078

15

0.32

0.25

DB-WAXetr

123-7312


HP-INNOWax

19091N-111

SUPELCOWAX 10

24079

30

0.25

0.25

DB-WAXetr

122-7332 19091N-133


HP-INNOWax

SUPELCOWAX 10

24081

60

0.25

0.25

DB-WAXetr

122-7362


HP-INNOWax

19091N-136

SUPELCOWAX 10

24082

60

0.32

0.25

DB-WAXetr

122-7362


HP-INNOWax

19091N-116

SUPELCOWAX 10

24083

15

0.32

0.5

DB-WAXetr

123-7313


HP-INNOWax

19091N-211

SUPELCOWAX 10

24084

30

0.32

0.5

DB-WAXetr

123-7333


HP-INNOWax

19091N-213

SUPELCOWAX 10

24169

30

0.2

0.2

DB-WAXetr

100-2000

Different dimensions

HP-INNOWax

19091N-102

SUPELCOWAX 10

24170

60

0.2

0.2

DB-WAXetr

100-2000

Different dimensions

HP-INNOWax

19091N-105

SUPELCOWAX 10

24211

30

0.32

1

DB-WAXetr

123-7334


SUPELCOWAX 10

24212

60

0.32

1

DB-WAXetr

123-7364


SUPELCOWAX 10

24284

30

0.25

0.5

DB-WAXetr

122-7333


HP-INNOWax

19091N-233

SUPELCOWAX 10

25324

15

0.53

0.5

DB-WAXetr

100-2000


SUPELCOWAX 10

25325

30

0.53

0.5

DB-WAXetr

100-2000


SUPELCOWAX 10

24343

15

0.1

0.1

DB-WAXetr

100-2000


SUPELCOWAX 10

25376

60

0.53

2

DB-WAXetr

100-2000


SUPELCOWAX 10

25385

60

0.53

0.5

DB-WAXetr

100-2000


SUPELCOWAX 10

25391

60

0.53

1

DB-WAXetr

125-7362


HP-INNOWax

19095N-126

SUPELCOWAX 10

24080-U

30

0.32

0.25

DB-WAXetr

123-7332


HP-INNOWax

19091N-113

SUPELCOWAX 10

24085-U

60

0.32

0.5

DB-WAXetr

123-7363


HP-INNOWax

19091N-216

SUPELCOWAX 10

25025-U

5

0.1

0.1

DB-WAXetr

100-2000


SUPELCOWAX 10

25026-U

10

0.1

0.1

DB-WAXetr

100-2000


SUPELCOWAX 10

25300-U

15

0.53

1

DB-WAXetr

125-7312


HP-INNOWax

19095N-121

SUPELCOWAX 10

25301-U

30

0.53

1

DB-WAXetr

125-7332


HP-INNOWax

19095N-121

SUPELCOWAX 10

25375-U

30

0.53

2

DB-WAXetr

125-7334


SUPEL-Q PLOT

24242

30

0.32

NA

HP-PLOT Q

19091P-Q04


SUPEL-Q PLOT

25462

30

0.53

NA

HP-PLOT Q

19095P-Q04


VOCOL

24127-U

60

0.32

1.8

DB-VRX

123-1564

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

HP-VOC

19091R-316

VOCOL

24129-U

10

0.2

1.2

DB-VRX

121-1524

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

VOCOL

24205-U

30

0.25

1.5

DB-VRX

122-1534

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

VOCOL

25320-U

30

0.53

3

DB-VRX

124-1534

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

VOCOL

24154

60

0.25

1.5

DB-VRX

122-1564

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

VOCOL

24157

60

0.32

3

DB-VRX

123-1564

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

VOCOL

25381

60

0.53

3

DB-VRX

124-1574

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

VOCOL

25358

105

0.53

3

DB-VRX

124-1574

Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.

HP-VOC

19095R-420