Skip to main content

Agilent J&W DB-1ms and HP-1ms Ultra Inert Capillary GC Columns


The Ultra Inert 1ms GC columns set the new industry standards for consistent column inertness and exceptionally low column bleed. These columns allow you to perform trace level analysis including the analysis of acids, bases, and other active compounds with the utmost confidence. They help ensure an inert GC flow path which is essential for sensitivity, performance, and the integrity of your results. The columns can be routinely used for applications in the environmental, forensics, foods/flavors/fragrances, pharmaceutical, and special chemical industries.

Demanding Ultra Inert 1ms Test Probe Mixture for Consistent Column Inertness Performance

The analysis of trace level samples and active compounds requires the most inert columns available. To meet the rigorous requirements that modern applications demand, a new Ultra Inert 1ms test probe mixture is adopted for testing each Ultra Inert 1ms column individually. The carefully selected chemical species known to adsorb onto active surfaces provide an in-depth evaluation of column inertness.

This new testing procedure is built on the already tightest industry QC specifications for bleed, sensitivity, and efficiency. It goes a long way in assuring a successful analysis for challenging analytes, providing you the most consistent column inertness performance.

 

Test Probe

Column Functional Test

1-Propionic acid

Basicity

1-Octene

Polarity

n-Octane

Hydrocarbon marker

1,2-Butanediol

Silanol

4-Picoline

Acidity

Trimethyl phosphate

Acidity

n-Propylbenzene

Hydrocarbon marker

1-Heptanol

Silanol

3-Octanone

Polarity

tert-Butylbenzene

Hydrocarbon marker

n-Decane

Hydrocarbon marker

 

Highest Degree of Column Inertness and Exceptional Low Column Bleed

Considered separately, neither low bleed nor low activity individually confers a significant advantage to trace analysis. Low bleed increases the signal-to-noise ratio, but if any of the analyte is adsorbed by active sites in the column, the results are flawed. Similarly, if the column is well deactivated but the bleed rate is high, some of the signal generated by the analyte is smothered by the bleed signal. Again, the results are flawed. Only when the column exhibits both low bleed and low activity are the results reliable.

Agilent J&W Ultra Inert columns are the only GC columns proven to deliver on the promise of consistent column inertness and exceptionally low column bleed.

 

Feature

Advantage

Benefits

Unique QC testing procedure with demanding Ultra Inert 1ms test probe mixture

Consistent column inertness performance

More reliable analytical results

Highest degree of column inertness

Better peak shape for active compounds

Improved detection limit and minimal preventive maintenance

Minimum compound loss or degradation

More accurate quantification and reliable results

More analysis without maintenance

Reduced costs and instrument downtime

Exceptionally low column bleed

Increased signal-to-noise ratio and sensitivity for all detectors

Improved detection limit and reliable compound identification

Fast baseline stabilization

Minimize conditioning time and improved productivity

Excellent thermal stability

Increased column lifetime, reduced instrument downtime

Narrow retention index window

Highest column-to-column reproducibility

Confident in analytical results

Minimal method adjustment when changing columns

Improved sample throughput and reduced instrument downtime

Support of 0.18mm ID column configuration

Increased speed without loss in resolution

Improved sample throughput and reduced cost per analysis

 

 

Ordering Details

 

Stationary Phase

Part number

I.D.
(mm)

Length
(m)

Film Thickness
(µm)

DB-1ms Ultra Inert

121-0122UI

0.18

20

0.18

122-0112UI

0.25

15

0.25

122-0132UI

0.25

30

0.25

122-0162UI

0.25

60

0.25

123-0112UI

0.32

15

0.25

123-0132UI

0.32

30

0.25

HP-1ms Ultra Inert

19091S-677UI

0.18

20

0.18

19091S-931UI

0.25

15

0.25

19091S-933UI

0.25

30

0.25

19091S-633UI

0.25

30

0.50

19091S-733UI

0.25

30

1.00

19091S-911UI

0.32

15

0.25

19091S-612UI

0.32

25

0.52

19091S-913UI

0.32

30

0.25

19091S-713UI

0.32

30

1.00