Human Genome CGH Microarrays - Details & Specifications
SurePrint G3 Human CGH Microarray Kit, 1x1M
| Feature | Specification |
| Agilent Product Number | G4447A |
| Design ID | 021529 |
| Format | 1 x 1M |
| Arrays/Slide | 1 |
| Slides/Kit | 5 |
| Distinct Biological Features | 963,029 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 6,685 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 2.1 KB overall median probe spacing (1.8 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
SurePrint G3 Human CGH Bundle, 1x1M
| Feature | Specification |
| Agilent Product Number | G5920A Option 1 |
| Design ID | 021529 |
| Format | 1x1M |
| Arrays/Slide | 1 |
| Slides/Kit | 50 |
| Distinct Biological Features | 963,029 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 6,685 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 2.1 KB overall median probe spacing (1.8 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
| SureTag Complete DNA Labeling Kit | 50 dual-color reactions |
| Oligo aCGH/ChIP-on-chip Hybridization Kit | 50 reactions |
| Microarray Slide Backing, 1x1M | 50 slides |
| Cot-1 DNA | 50 reactions |
| Wash Buffers | 50 reactions |
| Agilent CytoGenomics 2.0 Software | 1 License |
SurePrint G3 Human CGH Microarray Kit, 2x400K
| Feature | Specification |
| Agilent Product Number | G4448A |
| Design ID | 021850 |
| Format | 2 x 400K |
| Arrays/Slide | 2 |
| Slides/Kit | 5 |
| Distinct Biological Features | 411,056 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 5,126 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 5.3 KB overall median probe spacing (4.6 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
SurePrint G3 Human CGH Bundle, 2x400K
| Feature | Specification |
| Agilent Product Number | G5921A Option 1 |
| Design ID | 021850 |
| Format | 2x400K |
| Arrays/Slide | 2 |
| Slides/Kit | 25 |
| Distinct Biological Features | 411,056 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 6,685 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 5.3 KB overall median probe spacing (4.6 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
| SureTag Complete DNA Labeling Kit | 50 dual-color reactions |
| Oligo aCGH/ChIP-on-chip Hybridization Kit | 50 reactions |
| Microarray Slide Backing , 2x400K | 25 slides |
| Cot-1 DNA | 50 reactions |
| Wash Buffers | 50 reactions |
| Agilent CytoGenomics 2.0 Software | 1 License |
SurePrint G3 Human CGH Microarray Kit, 4x180K
| Feature | Specification |
| Agilent Product Number | G4449A |
| Design ID | 086332 |
| Format | 4 x 180K |
| Arrays/Slide | 4 |
| Slides/Kit | 3 |
| Distinct Biological Features | 170,334 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 6,539 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 13 KB overall median probe spacing (11 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
SurePrint G3 Human CGH Bundle, 4x180K
| Feature | Specification |
| Agilent Product Number | G5922A Option 1 |
| Design ID | 086332 |
| Format | 4x180K |
| Arrays/Slide | 4 |
| Slides/Kit | 12 |
| Distinct Biological Features | 170,334 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 6,685 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 13 KB overall median probe spacing (11 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
| SureTag Complete DNA Labeling Kit | 48 dual-color reactions |
| Oligo aCGH/ChIP-on-chip Hybridization Kit | 48 reactions |
| Microarray Slide Backing, 4x180K | 12 slides |
| Cot-1 DNA | 50 reactions |
| Wash Buffers | 48 reactions |
| Agilent CytoGenomics 2.0 Software | 1 License |
SurePrint G3 Human CGH Microarray Kit, 8x60K
| Feature | Specification |
| Agilent Product Number | G4450A |
| Design ID | 021924 |
| Format | 8 x 60K |
| Arrays/Slide | 8 |
| Slides/Kit | 3 |
| Distinct Biological Features | 55,077 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 3,886 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 41 KB overall median probe spacing (33 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
SurePrint G3 Human CGH Bundle, 8x60K
| Feature | Specification |
| Agilent Product Number | G5923A Option 1 |
| Design ID | 021924 |
| Format | 8x60K |
| Arrays/Slide | 8 |
| Slides/Kit | 6 |
| Distinct Biological Features | 55,077 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 3,886 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 41 KB overall median probe spacing (33 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
| SureTag Complete DNA Labeling Kit | 48 dual-color reactions |
| Oligo aCGH/ChIP-on-chip Hybridization Kit | 48 reactions |
| Microarray Slide Backing, 8x60K | 6 slides |
| Cot-1 DNA | 49 reactions |
| Wash Buffers | 48 reactions |
| Agilent CytoGenomics 2.0 Software | 1 License |
Human CGH Microarrays Human Genome CGH Microarray Kit, 4x44K
| Agilent Product Number | G4426B |
| Design ID | 014950 |
| Format | 4 x 44K |
| Arrays/Slide | 4 |
| Slides/Kit | 3 |
| Distinct Biological Features | 42,494 |
| Replicated Biological Features (X5) | 301 |
| Internal Quality Control Features | 2,118 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 43 KB overall median probe spacing (24 KB in Refseq genes) |
| Biological Probes Retained from Earlier 44K Format | 100% |
| Manufacturing | Agilent 60-mer SurePrint technology |
Human Genome CGH Microarray Kit 244A
| Feature | Specification |
| Agilent Product Number | G4411B |
| Design ID | 014693 |
| Format | 1 x 244K |
| Arrays/Slide | 1 |
| Slides/Kit | 5 |
| Distinct Biological Features | 236,381 |
| Replicated Biological Features (X5) | 1,000 |
| Internal Quality Control Features | 5,045 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 8.9 KB overall median probe spacing (7.4 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
Human Genome CGH Microarray Kit 105A
| Feature | Specification |
| Agilent Product Number | G4412A |
| Design ID | 014698 |
| Format | 2 x 105K |
| Arrays/Slide | 2 |
| Slides/Kit | 5 |
| Distinct Biological Features | 99,026 |
| Replicated Biological Features (X5) | 525 |
| Internal Quality Control Features | 4,626 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg18 (NCBI Build 36), March 2006 |
| Probe Spacing | 22 KB overall median probe spacing (19 KB in Refseq genes) |
| Manufacturing | Agilent 60-mer SurePrint technology |
Unrestricted HD-CGH Microarray ISCA v2, 2x105K
| Feature | Specification |
| Agilent Product Number | G4425B |
| Design ID | 031750 |
| Format | 2 x 105K |
| Arrays/Slide | 2 |
| Slides/Kit | 1 |
| Distinct Biological Features | 19,647 in ISCA regions + 80,757 backbone probes |
| Replicated Biological Features (X5) | 0 |
| Internal Quality Control Features | 4,626 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg19 (NCBI Build 37, February 2009) |
| Probe Spacing | 35 KB overall median probe spacing (higher in ISCA regions) |
| Manufacturing | Agilent 60-mer SurePrint technology |
SurePrint G3 Unrestricted CGH ISCA v2, 8x60K
| Feature | Specification |
| Agilent Product Number | G4827A |
| Design ID | 031746 |
| Format | 8 x 60K |
| Arrays/Slide | 8 |
| Slides/Kit | 1 |
| Distinct Biological Features | 18,851 in ISCA regions + 40,208 backbone probes |
| Replicated Biological Features | 0 |
| Internal Quality Control Features | 3,886 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg19 (NCBI Build 37, February 2009) |
| Probe Spacing | 60 KB overall median probe spacing (higher in ISCA regions) |
| Manufacturing | Agilent 60-mer SurePrint technology |
Unrestricted HD-CGH Microarray ISCA v2, 4x44K
| Feature | Specification |
| Agilent Product Number | G4426B |
| Design ID | 031747 |
| Format | 4 x 44K |
| Arrays/Slide | 4 |
| Slides/Kit | 1 |
| Distinct Biological Features | 2,934 in ISCA regions + 40,161 backbone probes |
| Replicated Biological Features | 0 |
| Internal Quality Control Features | 2,118 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg19 (NCBI Build 37, February 2009) |
| Probe Spacing | 75 KB overall median probe spacing (higher in ISCA regions) |
| Manufacturing | Agilent 60-mer SurePrint technology |
Unrestricted HD-CGH Microarray ISCA v2, 4x180K
| Feature | Specification |
| Agilent Product Number | G4826A |
| Design ID | 031748 |
| Format | 4 x 180K |
| Arrays/Slide | 4 |
| Slides/Kit | 1 |
| Distinct Biological Features | 21,445 in ISCA regions + 125,061 backbone probes |
| Replicated Biological Features | 5,305 |
| Internal Quality Control Features | 6,539 |
| Gene List Annotations Design Files Probe Sequences |
visit Agilent’s SureDesign application |
| Composition | Content sourced from - UCSC hg19 (NCBI Build 37, February 2009) |
| Probe Spacing | 25 KB overall median probe spacing (higher in ISCA regions) |
| Manufacturing | Agilent 60-mer SurePrint technology |
For Research Use Only. Not for use in diagnostic procedures