HP-1
HP-1
- Capillary
제품 정보
- 100% Dimethylpolysiloxane
- Non-polar
- Excellent general purpose columns - "Industry Standard"
- Superior performance of low molecular weight alcohols (< C5)
- Bonded and cross-linked; solvent rinsable
- Wide range of column dimensions available
- Equivalent to USP Phase G2
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1
| Capillary | |
| ID (mm) | 0.18 – 0.32 mm |
| Length (m) | 12 – 100 m |
| Film (µm) | 0.11 – 5.00 µm |
| Temperature Limits (°C) | -60 – 325/350 °C |
| -60 – 260/280 °C (3.00, 4.00, 5.00 µm) | |
| Megabore | |
| ID (mm) | 0.53 mm |
| Length (m) | 5 – 60 m |
| Film (µm) | 0.15 – 5.00 µm |
| Temperature Limits (°C) |
-60 – 260/280 °C (2.65, 3.00, 5.00 µm)
|
|
-60 – 300/320 °C (0.88, 1.50 µm)
|
|
|
-60 – 320/350 °C (0.88, 2.65 µm)
|
|
| -60 – 320/400 °C (0.15, 0.88 µm) | |
- 응용 자료
-
Using a Dual LTM Series II System with Flow Modulated Comprehensive GCxGC
Conventional flow modulated GCxGC usually consists of one first dimension column where both...
- 응용 자료
- English
- 11 Feb 2014
- 791.07 KB
Running ASTM Methods D4815 and D5580 on a Single Agilent 6890N Gas Chromatograph with Nitrogen Carrier Gas
Application note for the Agilent 6890N Gas Chromatograph with Nitrogen Carrier Gas
- 응용 자료
- English
- 10 Jan 2014
- 152.65 KB
Fast Determination of Denatured Fuel Ethanol Purity by Two-Dimensional Gas Chromatography
Application note for the fast determination of denatured fuel ethanol Purity by Two-Dimensional Gas Chromatography
- 응용 자료
- English
- 10 Jan 2014
- 149.49 KB
Two-Dimensional Gas Chromatographic Analysis of Trace Benzene in Styrene
A two-dimensional gas chromatographic method for the analysis of trace benzene in styrene is described.
- 응용 자료
- English
- 15 Oct 2012
- 917.01 KB
- 인용
- 기술 개요
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our interactive tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27