DB-WAXetr
DB-WAXetr
- Capillary
제품 정보
- Polyethylene glycol (PEG)
- High polarity
- Extended temperature range (etr)
- Excellent column-to-column repeatability
- Bonded, cross-linked and solvent rinsable
- Equivalent to USP Phase G16
- Agilent J&W GC columns are tested against the strictest industry QC specifications for column bleed, sensitivity, and efficiency to give you utmost confidence in qualitative and quantitative results
- For QC test conditions, including the test probe mixture and the resulting chromatogram, refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Similar Phases: SUPELCOWAX 10, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, Rtx-WAX, ZB-WAX, ZB-WAX plus
| ID (mm) | Length (m) | Film (µm) | Temp Limits (°C) | 7 in Cage | 5 in Cage | 7890/6890 LTM Module |
| 0.20 | 25 | 0.40 | 30 to 250/260 | 128-7323 | 128-7323LTM | |
| 0.25 | 30 | 0.25 | 30 to 260/280 | 122-7332 | 122-7332E | 122-7332LTM |
| 0.50 | 30 to 250/260 | 122-7333 | 122-7333LTM | |||
| 60 | 0.25 | 30 to 260/280 | 122-7362 | |||
| 0.50 | 30 to 250/260 | 122-7363 | ||||
| 0.32 | 15 | 0.25 | 30 to 260/280 | 123-7312 | 123-7312LTM | |
| 1.00 | 30 to 250/260 | 123-7332 | 123-7314LTM | |||
| 30 | 0.25 | 30 to 260/280 | 123-7332 | 123-7332LTM | ||
| 0.50 | 30 to 250/260 | 123-7333 | 123-7333LTM | |||
| 1.00 | 30 to 250/260 | 123-7334 | 123-7334LTM | |||
| 50 | 1.00 | 30 to 250/260 | 123-7354 | 123-7354E | ||
| 60 | 0.25 | 30 to 260/280 | 123-7362 | |||
| 0.50 | 30 to 250/260 | 123-7363 | ||||
| 1.00 | 30 to 250/260 | 123-7364 | ||||
| 0.53 | 15 | 1.00 | 30 to 240/260 | 125-7312 | 125-7332LTM | |
| 2.00 | 50 to 230/250 | 125-7314 | 125-7314LTM | |||
| 30 | 1.00 | 30 to 240/260 | 125-7332 | 125-7332E | 125-7332LTM | |
| 1.50 | 30 to 230/240 | 125-7333 | 125-7333LTM | |||
| 2.00 | 50 to 230/250 | 125-7334 | 125-7334E | 125-7334LTM | ||
| 60 | 1.00 | 30 to 240/260 | 125-7362 |
- 응용 자료
-
Analysis of N-nitrosodimethylamine (NDMA) in Water using GC Triple Quadrupole Mass Spectrometry
A method was developed on the 7890A Series GC and an 7000B Triple Quadrupole GC/MS mass spectrometer in PCI mode that provides sensitivity of ppt and lower for NDMA.
- 응용 자료
- English
- 29 Aug 2013
- 258.09 KB
- 인용
- 포스터
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks! www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our interactive tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27