DB-VRX
DB-VRX
- Capillary
제품 정보
- Unique selectivity engineered for optimum resolution of volatiles analysis:
U.S. EPA Methods 502.2, 524.2 and 8260 - 0.45 mm id columns provide more plates per meter compared to 0.53 mm id columns for the fewest co-elutions for GC method (an industry first)*
- No subambient cooling required to resolve the six "gases"
- Fast run time:
<30 minutes for optimum sample throughput
<8 minutes with 0.18 mm id - Low polarity
- Excellent peak shape
- Bonded and cross-linked
- Solvent rinsable
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
*Two co-elutions: 1) m- and p-xylene, for which U.S. EPA does not require separation, and 2) 1,1,2,2-tetrachloroethane and o-xylene which are separated by detectors PID and ELCD, respectively. Note to GC/MS analysts: These co-eluting compounds have different primary characteristic ions of 83 and 106, respectively.
Similar Phases: VOCOL, NON-PAKD, Rtx-Volatiles, PE-Volatiles, 007-624, Rtx-VRX, Rtx-VGC
| Capillary | |
| ID (mm) | 0.18 - 0.32 mm |
| Length (m) | 20 - 60 m |
| Film (µm) | 1.00 - 1.80 µm |
| Temperature Limits (°C) | -10 - 260 °C |
| Megabore | |
| ID (mm) | 0.45 mm |
| Length (m) | 30 - 75 m |
| Film (µm) | 2.55 µm |
| Temperature Limits (°C) | -10 - 260 °C |
- 주요 참고문헌
-
Agilent J&W GC Environmental Applications brochure
You are on the front lines in the battle to safeguard our natural resources from potentially harmful organic and inorganic contaminants in water, soil, air, and food.
- 브로셔
- English
- 18 Apr 2013
- 2.81 MB
- 브로셔
- 인용
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27