DB-FFAP
제품 정보
- Nitroterephthalic acid modified polyethylene glycol
- High polarity
- Designed for the analysis of volatile fatty acids and phenols
- Bonded and cross-linked; solvent rinsable
- Close equivalent to USP Phase G35
- Replaces OV-351
- Agilent J&W GC columns are tested against the strictest industry QC specifications for column bleed, sensitivity, and efficiency to give you utmost confidence in qualitative and quantitative results
- For QC test conditions, including the test probe mixture and the resulting chromatogram, refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Note: We do not recommend the use of water or methanol to rinse DB-FFAP GC columns
- Similar Phases: SPB-5, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, ZB-5, AT-5, MDN-5, ZB-5
Configuration choices for Agilent J&W DB-FFAP
|
Microbore | |
| ID (mm) | 0.10 mm |
| Length (m) | 10 – 15 m |
| Film (µm) | 0.10 µm |
| Temperature Limits (°C) | 40 – 250 °C |
| Capillary | |
| ID (mm) | 0.25 – 0.32 mm |
| Length (m) | 15 – 60 m |
| Film (µm) | 0.25 – 1.00 µm |
| Temperature Limits (°C) | 40 – 250 °C |
| Megabore | |
| ID (mm) | 0.45 – 0.53 mm |
| Length (m) | 10 – 60 m |
| Film (µm) | 0.25 – 1.00 µm |
| Temperature Limits (°C) | 40 – 250 °C |
- 응용 자료
-
A comparison study of the analysis of volatile organic acids and fatty acids
The Agilent J&W DB-FATWAX provides superior inertness, thermal stability, and retention time reproducibility compared to other commercially available WAX columns for the analysis of underivatized volatile organic acids and free fatty acids.
- 응용 자료
- English
- 10 Apr 2018
- 1.20 MB
Gases
Gas chromatography with Agilent J&W DB-FFAP and CP-Molsieve columns analyzes oxygen and water vapor in food packaging in less than four minutes.
- 응용 자료
- English
- 04 Nov 2013
- 550.39 KB
- 카탈로그
- 인용
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks! www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our interactive tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27