DB-5ms
DB-5ms
- Capillary
제품 정보
- Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane
- Non-polar with very low bleed characteristics, ideal for GC/MS
- Excellent inertness for active compounds
- Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
- Bonded and cross-linked
- Solvent rinsable
- Exact replacement of HP-5TA
- Close equivalent to USP Phase G27
- Test mix available
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Similar Phases: Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, PTE-5, BPX-5, AT-5ms, ZB-5ms, ZB-5MSi, SLB-5ms, Equity-5
| Capillary | |
| ID (mm) | 0.18 – 0.32 mm |
| Length (m) | 12 – 60 m |
| Film (µm) | 0.10 – 1.00 µm |
| Temperature Limits (°C) | -60 – 325/350 °C |
| Megabore | |
| ID (mm) | 0.53 mm |
| Length (m) | 15 – 30 m |
| Film (µm) | 0.50 – 1.50 µm |
| Temperature Limits (°C) | -60 – 300/320 °C |
- 응용 자료
-
중국 HJ 743-2015 분석법에 따른8890-5977B GC/MSD를 이용한 폴리염화비페닐(PCB) 분석
토양의 18종 indicator PCB 분석에 따른 8890-5977B 플랫폼 성능 평가
- 응용 자료
- Korean
- 24 Jul 2020
- 696.01 KB
Agilent GC/Q-TOF 시스템을 사용한 Amlodipine Besylate의 잠재적 유전독성 불순물 정량
GC/Q-TOF MS 데이터는 식별 및 정량에 쓰이고, MSMS 데이터는MSC 소프트웨어를 사용한 물순물 조각의 구조를 예측하는데에 쓰입니다.
- 응용 자료
- Korean
- 03 Jan 2019
- 693.12 KB
Fast Analysis of 18 Polychlorinated Biphenyls (PCBs) Using the Agilent Intuvo 9000 GC Dual ECD
This application note describes polychlorinated biphenyl (PCB) analysis based on an electron capture detection (ECD) and dual-column confirmation approach on the Agilent Intuvo 9000 GC.
- 응용 자료
- English
- 02 Dec 2022
- 973.93 KB
Analysis of Polychlorinated Biphenyls on 8890-5977B GC/MSD by Following the China HJ 743-2015 Method
Performance assessment of 889-5977B platform on the analysis of 18 indicator PCBs in soil
- 응용 자료
- English
- 02 Dec 2019
- 736.87 KB
Determination of Bath Salts (Pyrovalerone Analogs) in Biological Samples
A method has been developed on the Agilent 220 Quadrupole Ion Trap using EI-MS/MS for the identification and quantification of Pyrovalerone Analogs in biological samples.
- 응용 자료
- English
- 23 Jan 2017
- 453.21 KB
Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples
A method has been developed on the Agilent 220 Quadrupole Ion Trap using EI-MS for the identification and quantification of GHB in biological samples.
- 응용 자료
- English
- 23 Jan 2017
- 166.91 KB
Determination of Pentobarbital in Biological Samples
A method has been developed on the Agilent 220 Quadrupole Ion Trap using CI-MS for the identification and quantification of Pentobarbital in biological samples.
- 응용 자료
- English
- 23 Jan 2017
- 123.73 KB
Integrated Transcriptomics and Metabolomics Study of Retinoblastoma Using Agilent Microarrays and LC/MS/GC/MS
Integrated omics study involving Agilent mass spectrometry and microarray technologies along with Mass Profiler Professional and GeneSpring software
- 응용 자료
- English
- 21 Oct 2015
- 1.47 MB
Enhanced Metabolite Profiling from Bark of Alangium Salviifolium Using LC/MS and GC/Q-TOF Techniques
Fraction collection for metabolite enrichment, biphasic solvent extraction, orthogonal column chemistries, and LC/MS and GC/MS detection, lead to greater metabolite coverage.
- 응용 자료
- English
- 03 Sep 2015
- 1.90 MB
Multiresidue Analysis of Pesticides in Avocado with Bond Elut EMR-Lipid by GC/MS/MS
EMR-Lipid removes high-fat avocado matrix effectively, with better recovery, speed, robustness, cleanliness, excellent accuracy and precision of pesticides.
- 응용 자료
- English
- 31 Aug 2015
- 814.95 KB
- 카탈로그
- 인용
- 포스터
- 기술 개요
Save time - use our online GC Column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our interactive tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27