CP-Volamine
CP-Volamine
- Capillary
제품 정보
- Non-polar stationary phase
- Excellent stability for samples containing water expands the application range
- Maximum temperature of 265 °C for enhanced productivity
- Highly inert providing sharp amine peaks for accurate results
- Produces symmetrical peaks due to MPD (Multi-Purpose Deactivation) technology
- Excellent performance even when the sample contains water (not as sample matrix)
- Ideal for analyzing volatile amines like MMA, DMA and TMA (monomethyl, dimethyl and trimethyl amine)
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Similar Phases: Rtx-Volatile Amines
| Capillary | |
| ID (mm) | 0.32 mm |
| Length (m) | 15 - 60 m |
| Temperature Limits (°C) | 265/300 °C (15, 30 m) |
| 265/275 °C (60 m) | |
- 응용 자료
-
C1 – C3 amines
Gas chromatography with an Agilent J&W CP-Volamine column elutes volatile amines as symmetrical peaks, as well as low levels of alcohols, air and water.
- 응용 자료
- English
- 05 Dec 2024
- 211.48 KB
Analysis of chlorinated phenols
GC/MS separation of six chlorinated phenols using an Agilent J&W CP-Volamine column is achieved in 30 minutes.
- 응용 자료
- English
- 13 Jun 2014
- 829.27 KB
Volatile polar compounds
GC/MS separation of glycolaldehyde in monoethylene glycol using an Agilent J&W CP-Volamine column takes seven minutes.
- 응용 자료
- English
- 12 Jun 2014
- 743.44 KB
Polar volatile compounds
GC/MS with an Agilent J&W CP-Volamine column separates polar volatiles such as carbon dioxide, ammonia and water in under two minutes.
- 응용 자료
- English
- 06 Jun 2014
- 735.34 KB
Volatile sulfur compounds
GC/MS with an Agilent J&W CP-Volamine column separates volatile sulfur compounds in eight minutes.
- 응용 자료
- English
- 06 Jun 2014
- 717.00 KB
Volatile organic compounds
GC/MS with an Agilent J&W CP-Volamine column separates VOCs in less than four minutes.
- 응용 자료
- English
- 06 Jun 2014
- 697.69 KB
Amines and alcohols
MMEA and MDEA are used to remove sulfur compounds from hydrocarbons. Agilent J&W CP-Volamine is ideal for these highly polar compounds.
- 응용 자료
- English
- 06 Jun 2014
- 791.95 KB
Oxygenated compounds in glycol
Impurities in monoethylene glycol are detected by GC/MS with an Agilent J&W CP-Volamine column in six minutes.
- 응용 자료
- English
- 04 Jun 2014
- 679.68 KB
Glycols in water
GC/MS separation of three glycols in water using an Agilent J&W CP-Volamine column is achieved in 18 minutes.
- 응용 자료
- English
- 04 Jun 2014
- 771.30 KB
Oxygenated compounds
Oxygenated compounds are separated by GC/MS on the amine-deactivated Agilent J&W CP-Volamine capillary column in 13 minutes.
- 응용 자료
- English
- 04 Jun 2014
- 989.88 KB
- 브로셔
- 카탈로그
- 인용
- 홍보자료
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27