CP-Sil 88
CP-Sil 88
- Capillary
제품 정보
- High selectivity towards positional and geometric isomers for ease-of-use
- Highly substituted cyanopropyl phase
- Highest polarity, non-chemically bonded and stabilized
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Similar Phases: SP-2560, SP-2340, SP-2330, BPX-70, BPX-90
| Capillary | |
| ID (mm) | 0.25 - 0.32 mm |
| Length (m) | 25 - 50 m |
| Film (µm) | 0.20 µm |
| Temperature Limits (°C) | 50 - 225/240 °C |
- 응용 자료
-
Agilent 8890 GC에서 AOAC 2012.13에 따른 cis-trans FAME 분석의 시스템 적합성 보장
본 응용 자료는 Agilent 8890 GC에서 AOAC Method 2012.13에 따른 이유식 내 지방산 함량 분석에 대해 다룹니다.
- 응용 자료
- Korean
- 26 Nov 2019
- 660.50 KB
System Suitability for cis-trans FAMEs Analysis by AOAC 2012.13 on an Agilent 8890 GC
This application note demonstrates analysis of fatty acid content in milk following AOAC Method 2012.13 on an 8890 GC system
- 응용 자료
- English
- 18 Nov 2019
- 773.01 KB
FAME C18
Gas chromatography using an Agilent J&W CP-Sil 88 column separates 16 fatty acid methyl esters of conjugated linoleic acids in soya bean oil in 50 minutes.
- 응용 자료
- English
- 29 May 2014
- 751.57 KB
Halogenated hydrocarbons, C12
Gas chromatography with an Agilent CP-Sil 88 column separates over 50 chlorophenyls in 72 minutes.
- 응용 자료
- English
- 04 Nov 2013
- 683.07 KB
Fatty acid methyl esters
Gas chromatography using an Agilent J&W CP-Sil 88 CB column separates 12 fatty acids as their methyl esters in sunfish in 25 minutes.
- 응용 자료
- English
- 04 Nov 2013
- 836.29 KB
Fatty acid methyl esters (FAME) C4 – C18
Gas chromatography using an Agilent J&W CP-Sil 88 CB column separates 12 C4 to C18 fatty acid methyl esters in 15 minutes.
- 응용 자료
- English
- 04 Nov 2013
- 432.59 KB
- 카탈로그
- 홍보자료
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27
![]() |
TIPS & TOOLS |