CP-Sil 8 CB
CP-Sil 8 CB
- Capillary
제품 정보
- (5% phenyl) methylpolysiloxane
- Non-polar, General purpose phase
- Cross-linked and bonded
- Solvent rinsable and Low bleed
- High column-to-column reproducibility
- Wide choice of dimensions available
- Available in Fused Silica and UltiMetal
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Similar Phases: SPB-5, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, ZB-5, AT-5, MDN-5, ZB-5
| Capillary | |
| ID (mm) | 0.15 – 0.32 mm |
| Length (m) | 10 – 60 m |
| Film (µm) | 0.10 – 5.00 µm |
| Temperature Limits (°C) | -60 to 300/325 °C (5.00 µm) |
| -60 to 325/350 °C (0.40 - 1.20 µm) | |
| -60 to 330/350 °C (0.10 - 0.25 µm) | |
| Megabore | |
| ID (mm) | 0.53 mm |
| Length (m) | 10 – 100 m |
| Film (µm) | 0.50 - 5.00 µm |
| Temperature Limits (°C) | -60 to 290/325 °C (5.00 µm) |
| -60 to 305/330 °C (1.50, 2.00 µm) | |
| -60 to 315/340 °C (1.00 µm) | |
| -60 to 325/350 °C (0.50 µm) | |
| UltiMetal | |
| ID (mm) | 0.53 mm |
| Length (m) | 25 - 50 m |
| Film (µm) | 0.50 - 5.00 µm |
| Temperature Limits (°C) | -60 - 325/350 °C |
- 응용 자료
-
Drugs: Analysis of drugs of abuse (underivatized) in ecstasy tablet
Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five underivatized drugs of abuse in an ecstasy tablet in 15 minutes.
- 응용 자료
- English
- 11 Jan 2017
- 539.88 KB
Drugs: Analysis of drugs of abuse (underivatized) standard mixture
Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates 18 underivatized drugs of abuse in a standard mixture in 15 minutes.
- 응용 자료
- English
- 11 Jan 2017
- 545.91 KB
Determination of drugs of abuse: Ecstacy
Agilent J&W CP-Sil 8 CB GC columns are ideal for detecting ecstasy by GC/MS.
- 응용 자료
- English
- 11 Jan 2017
- 1.76 MB
Solvents
Gas chromatography using an Agilent CP-Sil 8 CB column separates ten chlorinated solvents in nine minutes
- 응용 자료
- English
- 24 Jun 2014
- 707.96 KB
Organic acids
GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 28 silylated organic acids in urine in 70 minutes.
- 응용 자료
- English
- 10 Jun 2014
- 819.37 KB
Semivolatile organic compounds
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 27semivolatiles in indoor air in 40 minutes.
- 응용 자료
- English
- 06 Jun 2014
- 1.42 MB
Chemicals
Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates chemical warfare agents in 24 minutes.
- 응용 자료
- English
- 29 May 2014
- 489.06 KB
Aromatics-Fast analysis of BTX
On-site air is monitored with Agilent 490 Micro GC and Agilent J&W CP-Sil 8 CB. Target components are aromatics, which can be measured within 150 s down to ppm.
- 응용 자료
- English
- 29 May 2014
- 500.11 KB
Pesticides
GC/MS of 15 pesticides is achieved in 20 minutes using an Agilent J&W CP-Sil 8 CB column.
- 응용 자료
- English
- 29 May 2014
- 687.93 KB
Phthalate esters
GC/MS of 16 phthalate esters is achieved in 33 minutes using an Agilent J&W CP-Sil 8 CB column.
- 응용 자료
- English
- 29 May 2014
- 675.30 KB
- 카탈로그
- 인용
- 홍보자료
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27