Cary UV Workstation Software
UV-Vis workflows designed for compliance and data integrity
- Next-generation Cary UV Workstation software includes streamlined methods for wavelength reads, scanning, concentration, kinetics, and temperature measurements. The software offers advanced calculations and extensive customization for tailored analyses. Advanced reporting capabilities allow the generation of detailed, precise reports. These enhancements help automate workflows and increase technical control, making Cary UV Workstation essential for any lab.
- For control of four independent temperature zones, use the Cary 3500 Multizone software add-on. Couple with Cary temperature probes to control the temperature from inside the cuvette. Configuration with OpenLab software ensures data is managed, protected, and securely stored in a local or central database.
- Streamline method setup with application-focused software that automatically detects your Agilent Cary 3500 UV-Vis configuration and only shows the parameters you need.
- Meet data integrity standards—provides the technical controls to acquire, process, report and store data securely in laboratories that must follow the compliance guidelines of FDA 21 CFR Part 11, EU Annex 11, GAMP5, as well as ISO/IEC 17025 and EPA’s 40 CFR Part 160.
- Perform advanced and customizable calculations using sample metadata. These calculations can be saved within a method and are automatically applied at the end of the sample sequence collection.
- The OpenLab software suite includes optional secure database storage for electronic records, complete administration for users and access privileges, software licensing, and security settings—e-signature workflow and enhanced audit trail review capabilities.
Overview
Key features
Effortless setup and smart detection
Built-in compliance and secure workflows
Smarter calculations and reporting
Flexible and secure data management
Complete control with OpenLab
Highlight and analyze with ease
Fast-response temperature control
On-demand help and training
Take UV-Vis to the next level with Cary UV Workstation software
Features and functionality that help labs work better, faster, and smarter
Set the parameters that matter
Streamline method setup with application-focused software that automatically detects your Cary 3500 UV‑Vis configuration—only showing the parameters you need.
Scan
Cary UV Workstation offers Scan mode, where users can obtain full spectral scans from UV to visible light, capturing the absorption characteristics of samples. Ideal for qualitative and quantitative analysis and determining the wavelength of maximum absorption.
Concentration
The Concentration mode simplifies quantitative analysis by using the Beer-Lambert law to calculate the concentration of analytes based on the absorbance at specific wavelengths. Preprogrammed methods and user-defined settings make this tool perfect for applications in chemical, pharmaceutical, and environmental testing.
Kinetic
With Kinetic mode, the software enables real-time monitoring of reactions, such as enzyme activity or chemical reactions, over time. This mode helps researchers track changes in absorbance over a specified period, offering powerful tools for studying reaction dynamics.
Thermal
The Thermal mode allows for temperature-controlled measurements, which are useful for thermal stability studies, denaturation studies, and dissociation experiments. This feature is essential in understanding how temperature affects molecular structures and reactions.
Multizone software add-on
The Cary 3500 Multizone software add-on can be used to control four independent temperature zones, and Cary temperature probes control the temperature from inside the cuvette.
Advanced and customizable calculations
Perform advanced and customizable calculations using sample metadata. These calculations can be saved within a method and are automatically applied at the end of the sample sequence collection.
Over 50 built-in calculations
Analyze your data with one of more than 50 built-in calculations or create your own.
Reporting flexibility and automation
Automatically export reports after sequence analysis with customizable location for LIMS integration. Include selectable content and zoomable graphs to emphasize key areas—saved within a method for consistent, efficient reporting.
Simplify audit trail review
Go paperless with an online review of records and audit trails and eliminate the need for maintaining hybrid records.
Full control of your e-signature workflows
Electronic signature workflow for executing signatures at different levels and meanings.
Automated tests for pharmacopeia compliance
Cary UV Workstation software includes automated test protocols for compliance with major pharmacopeias, including the U.S., European, and Japanese pharmacopeias. By automating these tests, the software streamlines the process, supporting organizations to meet full regulatory compliance while saving lab time and resources.
Specifications
How it works
Cary UV Workstation—speed, data quality, and reliability
The Cary UV Workstation software comes with built-in applications such as time-based kinetics, concentration, wavelength scanning, and temperature-based measurements. The intuitive software interface ensures methods are quick and easy to set up. Analyze your data with one of more than 50 built-in calculations or create your own. The built-in Help and Learning Center reduces training time and effort by providing easy-to-follow videos and information for all users.
Software to help meet global regulatory requirements
The Cary 3500 UV‑Vis spectrophotometer is compatible with the Agilent OpenLab software suite of products. OpenLab provides technical controls to securely acquire and store data in laboratories that must comply with FDA 21 CFR Part 11, EU Annex 11, GAMP5, ISO/IEC 17025, and the EPA’s 40 CFR Part 160 (and similar regulations in other countries). These controls include access control and secure data, electronic signature workflows, and advanced audit trail review.
Securing and managing Cary 3500 UV‑Vis data with OpenLab
OpenLab software ensures your data is securely stored. Agilent offers two configurations for the Cary UV Workstation:
- Data is stored and managed locally, on the PC attached to the Cary 3500 system
- Data is stored and managed centrally in one of the OpenLab software options shown in the following flyer
Documents & support
Everything you need to succeed
UV-Vis spectroscopy learning tools
Get your Basics of UV‑Vis Spectrophotometry handbook and a pack of four undergraduate teaching lab experiments.
Explore a detailed set of Cary UV Workstation FAQs
A wide-ranging set of FAQs on Cary 3500 and Cary UV Workstation general operation, data analysis, method development, and more.
Read Cary 3500 reviews
Explore customer reviews posted on SelectScience, or write your own review.
UV-Vis fundamentals
Learn the basics of UV‑Vis—how spectrophotometers work, UV-Vis analysis, applications, accessories, and measurement techniques.
UV-Vis and compliance
Learn about meeting UV‑Vis compliance requirements, protecting data, and guaranteeing accurate results.
Data integrity resource center
Explore relevant information on data integrity in the pharmaceutical industry.
News
Easy and Efficient Analysis of Ethanol Impurities using the Cary 3500 Flexible UV-Vis Spectrophotometer
This application note explores the use of an Agilent Cary 3500 Flexible UV-Vis spectrophotometer and a variable long-path-length holder to verify the purity levels of two ethanol samples in accordance with the US, European, and Japanese Pharmacopoeia monographs for ethanol. The results highlight how the Agilent Cary UV Workstation software enables the creation of simple, efficient processes for routine quality checks in pharmaceutical laboratories.
22 Apr 2026
Upgrade Cary UV Workstation: Smarter Reporting, Advanced Calculations, Seamless Compliance
Upgrade to Cary UV Workstation v1.6 for smarter workflows and customizable reporting. Autogenerate PDF/CSV reports, export to custom locations, and scale graphs for clarity. Use 50+ built-in or custom equations with sample metadata. Overlay spectra for easy comparisons. Supports USP <857>, Ph. Eur. 2.2.25, JP XVIII, OpenLab 2.8, ECM 3.6, and Windows 10/11 for compliance and seamless integration.
08 Oct 2025
Quality Control of Lithium-Ion Battery Electrolytes and Solvents by UV-Vis Spectroscopy
To maintain the safety, performance, and longevity of lithium-ion batteries (LIBs), it is essential to ensure the quality of LIB electrolytes (lithium salts in organic solvents). Discoloration may signal contamination or degradation. This study showcases a quality assessment method for LIB electrolytes using the Cary 3500 UV-Vis spectrophotometer with a Cary Sipper flow cell pump, ideal for safe, high-throughput quality control of production-critical chemicals.
26 Jul 2024
Frequently asked questions
What applications are included in Cary UV Workstation?
Cary UV Workstation includes applications for Scan, Concentration, Kinetics, Thermal, automated pharmacopeia tests, and System Health.
Which instruments are compatible with Cary UV Workstation?
The software is compatible with all models in the Agilent Cary 3500 UV‑Vis series:
- Cary 3500 Compact UV-Vis
- Cary 3500 Multicell UV-Vis
- Cary 3500 Flexible UV-Vis
Can you list some of the software features included in Cary UV Workstation?
The software offers customizable reporting, auto-generated reports, 50+ built-in calculations (or create custom equations using sample metadata), and spectrum overlay.
How does Cary UV Workstation help with regulatory compliance?
Cary UV Workstation supports global pharmacopeia standards such as: USP <857>, Ph. Eur. 2.2.25, and JP XVIII (JP 2.24). It also facilitates compliance with 21 CFR Part 11 and EU Annex 11 for electronic records and data integrity.
Can Cary UV Workstation be integrated with other Agilent software platforms?
Yes. It is fully compatible with Agilent OpenLab software, enabling data management and traceability.
How does Cary UV Workstation improve efficiency in the lab?
The software allows users to save calculations within methods for automatic execution, reducing manual data entry and minimizing errors. It also supports fast report generation and easy export to custom locations.
What options exist for storing and managing Cary 3500 UV-Vis data securely?
Agilent offers two options:
- Local storage on the PC connected to the Cary 3500 system
- Centralized storage using Agilent OpenLab software for secure data management, audit trails, and compliance with 21 CFR Part 11 and EU Annex 11
Can Cary UV Workstation integrate with Active Directory for user management?
Yes. Cary UV Workstation supports Active Directory integration, allowing centralized user authentication and role-based access control. This ensures secure login, streamlined account management, and compliance with IT policies across your organization.
Does Cary UV Workstation support customized e-signature workflows?
Yes. Cary UV Workstation allows you to configure electronic signature workflows to meet your organization’s compliance requirements. You can customize approval steps, assign roles, and ensure secure sign-off for critical actions—helping maintain data integrity and comply with regulations such as 21 CFR Part 11 and EU Annex 11.
What are the different Cary UV Workstation configurations?
Cary UV Workstation is available as the base version for nonregulated environments, Cary UV Workstation Plus for standalone regulated setups with OpenLab compliance tools (21 CFR Part 11), and Cary UV Networked Workstation for distributed regulated environments with centralized data management.
Style
Advance your lab with technical training
Not sure where to start? Our in-person and virtual training offerings can help you and your team achieve complete instrument familiarity and control
Online education for Cary 3500 UV-Vis and UV Workstation software
Learning path on UV‑Visible spectroscopy, Cary 3500 system components, and Cary UV Workstation software—so you can become a better Cary 3500 operator.
Molecular Spectroscopy Webinar Curriculum
Live and on-demand events on UV‑Vis, UV‑Vis‑NIR, fluorescence, handheld and benchtop FTIR, and Raman systems for high performance and flexibility.
Facilitating Data Integrity and Compliance—Advancing Pharmaceutical Technologies
This pharmaceutical expert presentation and discussion forum focuses on data integrity and compliance, particularly in QA/QC, development, and manufacturing.
Regulatory Trends and Compliance Insights for Molecular Spectroscopy
Webinar on the recent regulatory trends related to the use of molecular spectroscopy within regulated GxP laboratories.
Spectroscopy Digital Workshops and Bootcamps
Boost your skills with live virtual workshops and software bootcamps—covering spectroscopy, method development, and data analysis.
Related products
PRDT_3460715
PRDT_3460716
PRDT_3460714
PRDT_1331316
PRDT_3460715
PRDT_3460716
PRDT_3460714
PRDT_1331316
Software support and resources
Get support from our technical experts driving lab performance and reliability
World-class team of experts dedicated to you. Hand-selected from across the globe, each bringing a wealth of experience and expertise to help you solve your issue quickly and efficiently.
Submit a question
Contact our team of spectroscopy experts.
Software downloads
Manage and effectively operate your software licenses with SubscribeNet.
Software support lifecycle policy
Check the lifecycle status for revisions of the Agilent molecular spectroscopy suite of software products.
Contact support
Connect with your local Agilent team.