Cary 4000 UV-Vis spectrometer
Cary 4000 UV-Vis Spectrophotometer
Controlled by the Cary WinUV software, a Windows-based modular software, it can be ordered with specific modules for bio and pharma. The UV-Vis spectrophotometer has a number of optional accessories for liquid samples, like temperature control and multicell holders.
- UV-Vis & UV-Vis-NIR Instruments
Request a Quote
Product Details
- Measure beyond 8.0 absorbance units with reference beam attenuation
- WinUV software—a variety of applications from scanning to kinetics and thermal
- Versatile suite of accessories including temperature control, liquid and solid sample holders, solids autosamplers, multicell holders, and diffuse and specular reflectance accessories
- Variable slit widths (down to 0.01 nm) for optimum control over data resolution
- Large sample compartment with precision LockDown mechanism for quick changes of accessories
- Maximum light throughput using Schwarzchild coupling optics
- Minimal noise and stray light using a floating aluminum casting and double out-of-plane Littrow monochromator
- Extended dynamic range by attenuating the reference beam to be more equivalent to the sample's absorbance
- Nitrogen pumping—separate purging in the sample and monochromator compartments
| Control Software |
|
| Depth |
|
| Height |
|
| Light Source |
|
| Maximum Scanning Speed |
|
| Photometric Range (Abs) |
|
| Photometric System |
|
| Power Requirements |
|
| Spectral Bandwidth |
|
| Wavelength |
|
| Weight |
|
| Width |
|
| Z-height |
|
Double Beam Spectrophotometers
Double beam spectrophotometers are fast and accurate, using two beams of light—a sample beam and a reference beam—to correct instrument fluctuations in real-time.
Learn More- Key Literature
-
Cary 4000/5000/6000i Series UV-Vis-NIR Spectrophotometers Brochure
The Cary 4000/5000/6000i Series UV-Vis-NIR spectrophotometers are unrivaled, precise and flexible, and are designed to meet your application requirements
- Brochures
- English
- 13 Jul 2022
- 9.23 MB
Agilent Cary Universal Measurement Accessory (UMA)
Technical Overview of the Agilent Cary Universal Measurement Accessory (UMA)
- Technical Overviews
- English
- 05 Jun 2013
- 658.24 KB
Accessories for Agilent Cary UV‑Vis‑NIR Spectrophotometers
This accessory selection guide helps you tailor your UV-Vis-NIR setup to match your application needs.
- Selection Guides
- English
- 03 Nov 2025
- 1.74 MB
- Application Notes
- Brochures
- Catalogs
- Data Sheets
- Flyers
- Posters
- Primers
- Selection Guides
- White Papers
- FAQs
-
FAQ: Cary Win UV cool tricks on Graphics Windows
On most applications, there are some things we can do to make the graphics window look different and sometimes easier to read. This information relates to the use of the SCAN Application, but can also apply to other applications.
FAQ: How to Run Cary UV/Vis Instrument Performance Tests
When necessary, the operator of a Cary UV/Visible instrument can perform tests to access the performance of the instrument and software. The following steps outline execution of these performance tests.
Why Do We Perform a Zero and Baseline in Scan?
The purpose for zeroing is to balance both the reference beam and the sample beam. By adjusting to zero, the instrument readings reflect the absence of sample.
Why is My Cary Spectrophotometer Failing Initialization or Making a Screeching Noise?
Why is My Cary Spectrophotometer Failing Initialization or Making a Screeching Noise?
How Do I Perform a Cary 6x6 Method in Advanced Reads?
How Do I Perform a Cary 6x6 Method in Advanced Reads?
UV-Vis Spectroscopy and Spectrophotometry Overview
An introduction to the basics of UV-Vis spectroscopy and UV-Vis spectrophotometers, with FAQs on the fundamentals of UV-Vis, how UV-Vis spectrophotometers work, UV-Vis analysis, applications, accessories, and measurement techniques.
- Instruction Sheets
- Site Preparation Checklists
- Supplemental Information
- User Manuals
More help is just a click away
If you didn't find what you need, try these resources or contact a specialist
New Accessory Guide for Agilent Cary UV-Vis/NIR Spectrophotometers
This selection guide provides a high-level overview of the popular accessories for Cary 4567’000 spectrophotometers, to answer the question “what else can your instrument do?” The guide captures common queries relating to sample type, analytical requirements, and measurement mode. The guide is categorized into solid, liquid, and miscellaneous sections, with quick-reference tables to facilitate comparisons between measurement options.
- 24 Nov 2025
New Software Trilogy for Cary 4/5/6/7000 UV-Vis/NIR Spectrophotometers
Three new versions of software have been released for use with the Cary 4/5/6/7000 UV-Vis-NIR spectrophotometers. Cary WinUV Software (v6.6) is used to control the instruments, perform calculations, and create reports. Color Software (v6.5) performs calculations and produces reports against the internationally recognized color standards including CIE. AutoPro (v7.0) software is used with the Solids Autosampler for performing automated multi-sample analysis, or sample mapping.
- 13 May 2025
New Cary WinUV Color Software for Cary 4/5/6/7000 UV-Vis/NIR Spectrophotometers
A new version of Cary WinUV Color Software (v6.5) has been released for the Cary 4/5/6/7000 UV-Vis/NIR Spectrophotometers. This Color Software is suitable for Cary 4/5/6/7000 UV-Vis/NIR systems running on the Cary WinUV v6.5 software, or the recently released Cary WinUV v6.6 software.
- 01 Apr 2025
Read reviews on the Cary 4000 UV-Vis Spectrophotometer
Explore customer reviews posted on SelectScience, or write your own review.
UV-Vis Spectroscopy Learning Tools
Get your Basics of UV-Vis Spectrophotometry handbook, and a pack of four undergraduate teaching lab experiments.
UV-Vis-NIR Solid Sample Measurement Accessories Guide
Learn about key solid sample accessories for Cary 4000, 5000, 6000i, and 7000 spectrophotometers.
UV-Vis & UV-Vis-NIR Instrument Selection Guide
Find out which Agilent UV-Vis or UV-Vis-NIR spectrophotometer is best for your needs.
UV-Vis Spectrophotometer Applications Overview
A guide to modern UV-Vis spectrophotometer uses, measurement techniques, and their applications.
Molecular Spectroscopy Pharma & Biopharma Solutions Guide
Learn about products & applications in pharma & biopharma using UV-Vis, FTIR, fluorescence, SORS & TRS technology.