Refine Results
- Products
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Manufacturer Compatibility
-
Manufacturer Compatibility
- Particle Size
-
Particle Size
- Pore Size
-
Pore Size
- Unit Quantity
-
Unit Quantity
- LC Column Brand
-
LC Column Brand
- LC Column Maximum Temperature
-
LC Column Maximum Temperature
- Molecular Weight Lower Limit
-
Molecular Weight Lower Limit
- Molecular Weight Upper Limit
-
Molecular Weight Upper Limit
- Analysis Platform
-
Analysis Platform
- Language
-
Language
PLgel Olexis GPC columns are designed for analysis of high-mol wt polymers and high-temperature GPC.
Column for organic GPC/SEC analyses for high resolution, wide calibration, or preparative scale
Compare
Plgel MIXED-D, 100 x 10 mm, 5 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 200 Da to 400 kDa
-
Unit:
1 Each
-
Length:
100 mm

PLgel MIXED-A, 250 x 10 mm, 20 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform and TCB, oDCB to analyze non-polar polymers resolving range 500 Da to 40 MDa

Compare
Plgel MIXED-E, 300 x 10 mm, 3 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 25 kDa
-
Unit:
1 Each
-
Length:
300 mm

EasiCal PS2B Standard baseline
EasiCal PS2B Standard baseline
-
Hello All I am brand new to GPC and having some difficulty with my baselines on my PS2B standards (also on 2A as problem is reproducible) Details : Waters Alliance GPC, with RI detection MP : THF (stabilized) with 0.1 % (v/v) TFA Cal Stds : EasiCal PS-2; MW range 185K-625 @ ~ 0.5 mg/mL (paddle dissolved in 10 mL of MP) Column : Agilent PLgel 5um Mixed-D (age unknown, but few years likely) At the low end of my cal standards the peak baseline has changed from previous runs (see attached picture).
Different GPC columns in series - Ghost peaks and peak splitting
Different GPC columns in series - Ghost peaks and peak splitting
-
Hello, We recently installed a second column on our GPC to get a better resolution in the low Mw range. We currently have Agilent PL1110-6500 PLgel MIXED-C (200-2.000.000 Da) and Agilent PL1113-6520 OligoPore (100-3.300 Da) in series. After installation we noticed several ghost peaks on all our samples, overlapping with the PS-M EasiVial calibration samples (162-364.000 Da).
LC and LC/MS Columns - USP Designations
LC and LC/MS Columns - USP Designations
-
Packing having densely bonded zwitterionic groups with 1:1 charge balance AdvanceBio MS Spent Media Poroshell HILIC-Z L118 Aqueous polymerized C18 groups on silica particles, 1.2 to 5 µm in diameter Pursuit PAH ChromSpher PAH L128 Porous particles of polystyrene divinyl benzene with linear molecular weight operating range from 200 to 2,000,000 g/mol (polystyrene equivalent), 5 µm in diameter Plgel MIXED C ## Official designation pending: (Emtricitabine, Chirobiotic V)- Vancomycin glycopeptide covalently bonded to silica particles, about 5 µm in diameter Poroshell Chiral-V Poroshell Chiral-V ## (Polyethylene Glycol 3350, Aquagel OH 40) – Packing having the capacity to separate compounds with a molecular weight range from 10,000 to 200,000 g/mol (as determined by polyethylene oxide), applied to neutral, anionic, and cationic water-soluble polymers, composed of a rigid macroporous material with a hydrophilic surface PL-Aquagel-OH 40 Allowed Changes to USP Methods
Compare
PLgel 7.5 x 50 mm, 20 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 20µm PLgel analytical columns 7.5 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel 7.5 x 50 mm, 3 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 3µm PLgel analytical columns 7.5 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel Olexis, 7.5 x 50 mm, 13 µm guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 13µm PLgel Olexis analytical columns 7.5 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel MIXED-B LS, 7.5 x 300 mm, 10 µm. Linear mixed light-scattering detection ready GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform and TCB, oDCB to analyze non-polar polymers resolving range 500 Da to 10 MDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel MIXED-A LS, 7.5 x 300 mm, 20 µm. Linear mixed light-scattering detection ready GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform and TCB, oDCB to analyze non-polar polymers resolving range 500 Da to 40 MDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 10^6Å, 7.5 x 300 mm, 20 µm. GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 600 kDa to 10 MDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 100Å, 7.5 x 300 mm, 3 µm. GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 5 kDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel Olexis, 7.5 x 300 mm, 13 µm. High temperature GPC/SEC column for chlorinated and other organic eluents e.g., TCB, oDCB to analyze polyolefin and performance polymers resolving range 500 Da to 10 MDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 100Å, 7.5 x 600 mm, 5 µm. GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 5 kDa
-
Unit:
1 Each
-
Length:
600 mm

Compare
PLgel 100Å, 25.0 x 25 mm, 10 µm, guard. GPC/SEC guard column to protect and extend the lifetime of preparative columns. Suitable for use with 10µm PLgel preparative columns 25 mm internal diameter
-
Unit:
1 Each
-
Length:
25 mm

Compare
PLgel MIXED-B, 25.0 x 300 mm, 10 µm. Linear mixed GPC/SEC preparative column for non-polar organic eluents e.g., THF, Toluene, Chloroform and TCB, oDCB to separate non-polar polymers resolving range 500 Da to 10 MDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 50Å, 25.0 x 300 mm, 10 µm. GPC/SEC preparative column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 100 Da to 1.5 kDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 100Å, 25.0 x 300 mm, 10 µm. GPC/SEC preparative column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 100 Da to 5 kDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 500Å, 25.0 x 300 mm, 10 µm. GPC/SEC preparative column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 100 Da to 25 kDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 1000Å, 25.0 x 300 mm, 10 µm. GPC/SEC preparative column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 200 Da to 60 kDa
-
Unit:
1 Each
-
Length:
300 mm
