Refine Results
- Products
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Manufacturer Compatibility
-
Manufacturer Compatibility
- Particle Size
-
Particle Size
- Pore Size
-
Pore Size
- Unit Quantity
-
Unit Quantity
- LC Column Brand
-
LC Column Brand
- LC Column Maximum Temperature
-
LC Column Maximum Temperature
- Molecular Weight Lower Limit
-
Molecular Weight Lower Limit
- Molecular Weight Upper Limit
-
Molecular Weight Upper Limit
- Analysis Platform
-
Analysis Platform
- Language
-
Language
Compare
PLgel 10^4Å, 25 x 300 mm, 10 µm GPC/SEC Preparative Column. For non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 10 kDa to 450 kDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 10^5Å, 25 x 300 mm, 10 µm GPC/SEC Preparative Column. For non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 60 kDa to 1.7 MDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel 10^6Å, 25 x 300 mm, 10 µm. GPC/SEC preparative column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 600 kDa to 10 MDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
PLgel MiniMIX-B, 4.6 x 50 mm, 10 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 10µm MiniMix-B analytical columns 4.6 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel MiniMIX-A, 4.6 x 50 mm, 20 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 20µm MiniMix-A analytical columns 4.6 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel MiniMIX-E, 4.6 x 50 mm, 3 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 3µm MiniMix-E analytical columns 4.6 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel MiniMIX-C, 4.6 x 50 mm, 5 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 5µm MiniMix-C analytical columns 4.6 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel MiniMIX-D, 4.6 x 50 mm, 5 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 5µm MiniMix-D analytical columns 4.6 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel 100Å, 4.6 x 50 mm, 5 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 5µ PLgel analytical columns 4.6 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
PLgel MiniMIX-B, 4.6 x 250 mm, 10 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform and TCB,oDCB to analyze non-polar polymers resolving range 500 Da to 10 MDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
PLgel MiniMIX-A, 4.6 x 250 mm, 20 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform and TCB, oDCB to analyze non-polar polymers resolving range 500 Da to 40 MDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
PLgel MiniMIX-E, 4.6 x 250 mm, 3 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 25 kDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
PLgel 100Å, 4.6 x 250 mm, 3 µm. GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 5 kDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
PLgel MiniMIX-C, 4.6 x 250 mm, 5 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 200 Da to 2 MDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
PLgel MiniMIX-D, 4.6 x 250 mm, 5 µm. Linear mixed GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 200 Da to 400 kDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
PLgel 100 Å, 250 x 4.6 mm, 5 µm. GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 5 kDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
PLgel 500 Å, 250 x 4.6 mm, 5 µm. GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 25 kDa
-
Unit:
1 Each
-
Length:
250 mm