Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Services
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
-
Instrument
- Method
-
- Agency Method
-
Agency Method
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Outer DIameter
-
Outer DIameter
- Packaging
-
Packaging
- Model
-
Model
- Solvent
-
Solvent
- Analyte
-
Analyte
- CAS Number
-
CAS Number
- Concentration
-
Concentration
- Format
-
Format
- Technique
-
Technique
- Unit Quantity
-
Unit Quantity
- Volume
-
Volume
- Analysis Platform
-
Analysis Platform
- MS Instrument Compatibility
-
MS Instrument Compatibility
- Spectroscopy Instrument Compatibility
-
Spectroscopy Instrument Compatibility
- Language
-
Language
Need help finding the right ICP supplies? Try our ICP Supplies Selector Tool.
Agilent ICP-MS autodiluter supplies, also referred to as ICP-MS inline dilution supplies, are designed for the Agilent ADS 2 autodilution system. Agilent ICP-MS ADS 2 autodilution system supplies include prebuilt replacement tubing kits, valve...
The ICP-MS torch forms and stabilizes an inductively coupled argon plasma, allowing injection of the sample aerosol through a central channel. The Fassel torch design comprises of 3 concentric tubes encircled by a copper, water-cooled...
Agilent ICP-MS systems utilize innovative technology to deliver excellent sensitivity, accuracy, ease-of-use, and productivity. Choose from single quadrupole ICP-MS systems and triple quadrupole ICP-MS systems designed to meet the needs of any...
ICP-MS cones, consisting of a Sampler cone and Skimmer cone, form the interface region between the atmospheric ICP and the high vacuum MS detector. Agilent offers interface cones that have either a Nickel or Platinum tip. Pt cones are used for...
Agilent's ICP-MS Software range can help to guide you through your workflows, control your systems remotely via a browser, control access, connect hyphenated systems and comply with 21CFR11 regulations.
PA Factors for LA-ICP-MS (and solution ICP-MS)
PA Factors for LA-ICP-MS (and solution ICP-MS)
-
We primarily analyse geological materials. Recently we have been doing lots of work to optimise our LA-ICP-MS performance with the aim of analysing more solid silicate minerals here in our lab. We find the PA settings in MassHunter are rather inflexible, as in you can only store one set, the current set, and you cannot upload/modify these manually.
Determination of elements in phosphoric acid using ICP-MS and ICP-OES
Determination of elements in phosphoric acid using ICP-MS and ICP-OES
-
The following elements are to be analysed: aluminum, arsenic, gold, barium, calcium, cadmium, chromium, copper, iron, potassium, lithium, magnesium, manganese, sodium, nickel, lead, sulphur, antimony, silicon, tin, strontium, titanium, vanadium and zinc. In an older Agilent ICP-MS application (Agilent 7500 ICP-MS), I read that phosphoric acid must be diluted to at least 1:100. Is the viscosity of the phosphoric acid the problem? Furthermore, I have read in a Perkin-Elmer ICP-OES application (Optima 8300) that, in this case, the phosphoric acid only needs to be diluted 1:10. As we do not have an ICP-MS-QQQ, we would need to measure the silicon and sulphur using OES; we would also measure the calcium, potassium and sodium using OES.
SOP ICP-MS-OES
SOP ICP-MS-OES
-
/anode-material-manufacture 1) Procedimiento operativo estándar para la determinación de elementos en materiales de ánodo de grafito y silicio-carbono para baterías de iones de litio. 2) Procedimiento operativo estándar: Determinación de elementos en materiales catódicos de fosfato de hierro y litio para baterías de iones de litio. www.agilent.com/.../sop-lib-cathode-icp-oes-5994-5435en-agilent_sample.pdf Si existen otros procedimientos operativos estándar (POE) relacionados con ICP-MS, le agradecería que me los enviara. Esto sería de gran ayuda para la validación de métodos tanto para ICP-MS como para ICP-OES. Atentamente, Andrés Luis.
ICP-MS Tips and Tricks and more!
ICP-MS Tips and Tricks and more!
-
Hi ICP-MS friends, I wanted to remind you that The ICP-MS Journal ( The ICP-MS Journal | Agilent ) has articles in ICP-MS (unsurprisingly) as well as a growing number of software and maintenance Tips & Tricks. We currently have some articles (including videos) for the following MassHunter Tips: ICP-MS MassHunter Autocalibration Assistant ( ICP-MS MassHunter Autocalibration Assistant | Agilent ) Using ICP-MS MassHunter Sublists ( Using ICP-MS MassHunter Sublists | Agilent ) Configuring ICP-MS MassHunter Custom Views ( Configuring ICP-MS MassHunter Custom Views | Agilent ) We also have other tips articles: Maintenance Tips for ICP-MS Interface Cones ( Maintenance Tips for ICP-MS Interface Cones | Agilent ) Cones FAQ's ( ICP-MS Cones Fundamentals | Agilent ) The ICP-MS Journal also features lots of application articles contributed by Agilent chemists as well as our amazing customers.
Inert kits for 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS. Including PFA nebulizer and spray chambers with demountable torch and platinum or sapphire injector. Suitable for analysis of HF, trace boron and silicon and semiconductor applications
The Agilent switching valve supplies (AVS MS or ISIS) for 7700, 7800, 7900, 8800, 8900 ICP-MS ensures your laboratory productivity. Find switching valve parts, including sample loops for high throughput sample introduction on ICP-MS.
Agilent offer ICP-MS spray chambers and spray chamber components, including ICP-MS end caps and ICP-MS connector tubes, designed for use with Agilent 7700, 7800, 7850, 7900, 8800, and 8900 ICP-MS instruments. |Agilent use Scott double-pass spray...
Agilent ICP-MS analyzers offer an integrated package of hardware, software, consumables, onsite implementation services, and documentation to significantly reduce the time required from system arrival to running regulated methods.
The ICP-MS requires high purity ICP tubing to connect the sample introduction for delivering sample solutions and for the gas supply to the instrument. Our ICP-MS tubing has customized length and diameter in high purity materials to meet the needs...
Pneumatic Nebulizers are used to convert liquid to a fine aerosol suitable for introduction into the inductively coupled plasma to achieve ionization. The aim is to achieve particle size sub-10µm with narrow particle size distribution. Agilent...
Genuine instrument supplies for ICP-MS such as O-rings, filters, gas regulators, detectors, tools and manuals. Accessories to enhance ICP-MS functionality include argon humidifier, UHMI and HMI aerosol dilution and hydride generation.
SPS 4 and integrated autosampler (I-AS) supplies and accessories minimize sample contamination and maximize Agilent ICP-MS productivity. Find high volume, dual position rinse kits, covers, probes and sample racks.
Keep your Agilent MS40+, DS402 & Edwards E2M18 ICP-MS foreline vacuum pump and cooling system working efficiently with Agilent supplies. We offer vacuum pump fluid/oils and oil mist filters and chiller/recirculator coolant fluids & filters.
From ICP-MS standard operating supplies to application specific kits, Agilent has comprehensive kits available with the parts and supplies needed to guarantee the performance, reliability, and longevity of your instruments.
Agilent provides a complete range of ICP-MS accessories, including autosamplers, UHMI, ISIS 3, as well as speciation and connection kits, compatible with Agilent ICP-MS and ICP-QQQ instruments, for total flexibility in your ICP-MS applications.
Replacement kits and individual components for replacement of Ion extraction lenses and Octopole Reaction System (ORS) cell for 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS with routine, x-lens, or semiconductor, s-lens, configuration.
Agilent offers a complete solution for speciation analysis with Agilent 7700, 7800, 7900, 8800, 8900 ICP-MS, and Infinity LC instruments. Including HPLC-ICP-MS & GC-ICP-MS parts & interface supplies, columns and application specific set up
The Agilent ICP-MS Software range can help to guide you through your workflows, control your systems remotely via a browser, control access, connect hyphenated systems, and comply with 21CFR11 regulations.
Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is a very popular technique for the analysis of elements in a wide range of samples. It is a very sensitive technique and can measure very low concentrations, even in challenging matrices. To...