Refine Results
- Products
-
- Applications and Industries
- Content Type
-
Content Type
- Unit Quantity
-
Unit Quantity
- Research Area
-
Research Area
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Cell Line
-
Cell Line
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Cell Type
-
Cell Type
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Analysis Platform
-
Analysis Platform
- Author
-
Author
- Journal
-
Journal
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Assay
-
Assay
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Language
-
Language
To be enabled for e-commerce, you must first register. Agilent will then confirm your registration and inform you when your enablement is complete and you can begin transacting.
E-commerce is currently not available in your country. For select consumables and supplies you may now use Saved Cart link under your Account to build lists and send to your Agilent Representative. Simply login or register and you may begin.
- Journal: Cancer Res
- Publication Date: 01 Feb 2018
- Author: Chiu GS , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | G S Chiu, M A Maj, S Rizvi, R Dantzer, E G Vichaya, G Laumet, A Kavelaars, and C J Heijnen |
|---|---|
| Journal | Cancer Res |
| Publication Date | 01 Feb 2018 |
| Research Area(s) include | Cancer Research, Neurobiology Research, Toxicology Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Cortical Synaptosomes |
| Cell Type(s) include | Neuronal cells |
| Species | Mouse |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | Not Specified |
| Plate Coating | Geltrex |
- Journal: Oxid Med Cell Longev
- Publication Date: 01 May 2016
- Author: Yamamoto H , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Yamamoto H, Morino K, Mengistu L, Ishibashi T, Kiriyama K, Ikami T, Maegawa H |
|---|---|
| Journal | Oxid Med Cell Longev |
| Publication Date | 01 May 2016 |
| Research Area(s) include | Cell Physiology Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Myotubes |
| Cell Type(s) include | Myotubes |
| Species | Mouse |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | Not Specified |
| Plate Coating | Not Specified |
- Journal: Amino Acids
- Publication Date: 01 Oct 2013
- Author: Vaughan RA , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Vaughan RA, Garcia-Smith R, Gannon NP, Bisoffi M, Trujillo KA, Conn CA |
|---|---|
| Journal | Amino Acids |
| Publication Date | 01 Oct 2013 |
| Research Area(s) include | Cell Physiology Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | C2C12, RD cells |
| Cell Type(s) include | Myoblasts, Rhabdomyosarcoma |
| Species | Human, Mouse |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 2.5x10^5 cells/well, 5.0x10^5 cells/well |
| Plate Coating | Not Specified |
- Journal: J Cell Biochem
- Publication Date: 01 Mar 2016
- Author: Radde BN , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Radde BN, Alizadeh-Rad N, Price SM, Schultz DJ, Klinge CM |
|---|---|
| Journal | J Cell Biochem |
| Publication Date | 01 Mar 2016 |
| Research Area(s) include | Cancer Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | MCF7, MDA-MB-231 |
| Cell Type(s) include | Breast cancer cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | Not Specified |
| Plate Coating | Not Specified |
- Journal: Stem Cells Dev
- Publication Date: 01 July 2016
- Author: Hajmousa G , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Hajmousa G, Elorza AA, Nies VJ, Jensen EL, Nagy RA, Harmsen MC |
|---|---|
| Journal | Stem Cells Dev |
| Publication Date | 01 July 2016 |
| Research Area(s) include | Obesity, Diabetes, and Metabolic Disorders |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Adipose derived stem cells (ADSC) |
| Cell Type(s) include | Stem cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | Not Specified |
| Plate Coating | Not Specified |
- Journal: PLoS One
- Publication Date: 01 Mar 2014
- Author: Huang L , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Huang L, Yu Z, Zhang T, Zhao X, Huang G |
|---|---|
| Journal | PLoS One |
| Publication Date | 01 Mar 2014 |
| Research Area(s) include | Cancer Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | A549 |
| Cell Type(s) include | Lung cancer cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 2.0x10^4 cells/well |
| Plate Coating | Not Specified |
- Journal: Stem Cells
- Publication Date: 01 July 2013
- Author: Cherry AB , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Cherry AB, Gagne KE, McLoughlin EM, Baccei A, Gorman B, Hartung O, Miller JD, Zhang J, Zon RL, Ince TA, Neufeld EJ, Lerou PH, Fleming MD, Daley GQ, Agarwal S |
|---|---|
| Journal | Stem Cells |
| Publication Date | 01 July 2013 |
| Research Area(s) include | Translational Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | iPSC |
| Cell Type(s) include | Stem cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 5.0x10^4 cells/well |
| Plate Coating | Matrigel |
- Journal: Nitric Oxide
- Publication Date: 01 Jan 2019
- Author: Leake A , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Leake A, Salem K, Madigan MC, Lee GR, Shukla A, Hong G, Zuckerbraun BS and Tzeng E |
|---|---|
| Journal | Nitric Oxide |
| Publication Date | 01 Jan 2019 |
| Research Area(s) include | Immunology Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Peritoneal macrophage |
| Cell Type(s) include | Immune cells |
| Species | Mouse |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | Not Specified |
| Plate Coating | Not Specified |
- Journal: J Biomed Sci
- Publication Date: 22 May 2019
- Author: Chan CM , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | C M Chan, D Y Huang, P Sekar, S H Hsu, and W W Lin |
|---|---|
| Journal | J Biomed Sci |
| Publication Date | 22 May 2019 |
| Research Area(s) include | Aging Research, Neurobiology Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | ARPE-19 |
| Cell Type(s) include | Retinal cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 4.0x10^5 cells/well |
| Plate Coating | Not Specified |
- Journal: Adv Biol Regul
- Publication Date: 28 Dec 2017
- Author: Zdralevic M , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | M Zdralevic, M Vucetic, B Daher, I Marchiq, S K Parks, and J Pouyssegur |
|---|---|
| Journal | Adv Biol Regul |
| Publication Date | 28 Dec 2017 |
| Research Area(s) include | Cancer Research, Review Papers |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | B16 |
| Cell Type(s) include | Melanoma cells |
| Species | Mouse |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | Not Specified |
| Plate Coating | Not Specified |
- Journal: Mitochondrion
- Publication Date: 01 Feb 2015
- Author: Nalbandian A , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Nalbandian A, Llewellyn KJ, Gomez A, Walker N, Su H, Dunnigan A, Chwa M, Vesa J, Cristina Kenney M, Kimonis VE |
|---|---|
| Journal | Mitochondrion |
| Publication Date | 01 Feb 2015 |
| Research Area(s) include | Neurobiology Research, Translational Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Fibroblasts |
| Cell Type(s) include | Fibroblast |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 2.5x10^4 cells/well |
| Plate Coating | Not Specified |
- Journal: Biosci Rep
- Publication Date: 30 Apr 2019
- Author: Chausse B , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | B Chausse, P A Kakimoto, C C Caldeira-da-Silva, A B Chaves-Filho, M Y Yoshinaga, R P da Silva, S Miyamoto, and A J Kowaltowski |
|---|---|
| Journal | Biosci Rep |
| Publication Date | 30 Apr 2019 |
| Research Area(s) include | Immunology Research, Neurobiology Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | BV-2 |
| Cell Type(s) include | Neuronal cells |
| Species | Mouse |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 2.0x10^4 cells/well |
| Plate Coating | Not Specified |
- Journal: Cell Metab
- Publication Date: 02 July 2019
- Author: Kumar S , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | S Kumar, H Sharife, T Kreisel, M Mogilevsky, L Bar-Lev, M Grunewald, E Aizenshtein, R Karni, I Paldor, T Shlomi, and E Keshet |
|---|---|
| Journal | Cell Metab |
| Publication Date | 02 July 2019 |
| Research Area(s) include | Cancer Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | U87-MG-GFP |
| Cell Type(s) include | Glioblastoma |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 5.0x10^4 cells/well |
| Plate Coating | Fibronectin |
- Journal: APL Bioeng
- Publication Date: 17 July 2018
- Author: Sessions AO , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | A O Sessions, P Min, T Cordes, B J Weickert, A S Divakaruni, A N Murphy, C M Metallo, and A J Engler |
|---|---|
| Journal | APL Bioeng |
| Publication Date | 17 July 2018 |
| Research Area(s) include | Aging Research, Cardiovascular Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Embryonic hearts |
| Cell Type(s) include | Cardiac cells |
| Species | Drosophila melanogaster |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 1 heart/well |
| Plate Coating | Not Specified |
- Journal: Cell Death Dis
- Publication Date: 08 June 2017
- Author: Sun S , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223+Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Sun S, Liu J, Zhao M, Han Y, Chen P, Mo Q, Wang B, Chen G, Fang Y, Tian Y, Zhou J, Ma D, Gao Q, Wu P |
|---|---|
| Journal | Cell Death Dis |
| Publication Date | 08 June 2017 |
| Research Area(s) include | Cancer Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96), Seahorse XFe24/XF24 |
| Cell Line(s) include | A549, SK-OV-3 |
| Cell Type(s) include | Lung cancer cells, Ovarian cancer cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 2.5x10^4 cells/well, 8.0x10^3 cells/well |
| Plate Coating | Not Specified |
- Journal: ChemMedChem
- Publication Date: 17 Oct 2019
- Author: Sileikyte J , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Sileikyte J, Devereaux J, de Jong J, Schiavone M, Jones K, Nilsen A, Bernardi P, Forte M, and Cohen MS |
|---|---|
| Journal | ChemMedChem |
| Publication Date | 17 Oct 2019 |
| Research Area(s) include | Drug Discovery |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | HeLa, Isolated mitochondria |
| Cell Type(s) include | Cervical cancer cells, Isolated mitochondria |
| Species | Human, Mouse |
| Assay / Method | Cell Mitochondrial Stress Test with additional injection |
| Cell Seeding Density | 3.0x10^4 cells/well, 5 µg/well |
| Plate Coating | Not Specified |
- Journal: Mol Cell
- Publication Date: 02 Jan 2020
- Author: Zhu Y , et al.
103015-100+103020-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Zhu Y, Gu L, Lin X, Liu C, Lu B, Cui K, Zhou F, Zhao Q, Prochownik EV, Fan C and Li Y |
|---|---|
| Journal | Mol Cell |
| Publication Date | 02 Jan 2020 |
| Research Area(s) include | Cancer Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | HEK293 |
| Cell Type(s) include | Embryonic kidney cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test, Glycolysis Stress Test |
| Cell Seeding Density | 3.0x10^4 cells/well |
| Plate Coating | Not Specified |
- Journal: PLoS One
- Publication Date: 01 Oct 2013
- Author: Zhang Y , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Zhang Y, Marsboom G, Toth PT, Rehman J |
|---|---|
| Journal | PLoS One |
| Publication Date | 01 Oct 2013 |
| Research Area(s) include | Stem Cell Biology |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Adipocytes, Mesenchymal stem cells |
| Cell Type(s) include | Adipocytes, Stem cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 1.0x10^5 cells/well |
| Plate Coating | Not Specified |
- Journal: Cell Stem Cell
- Publication Date: 01 May 2016
- Author: Yamada M , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Yamada M, Emmanuele V, Sanchez-Quintero MJ, Sun B, Lallos G, Paull D, Zimmer M, Pagett S, Prosser RW, Sauer MV, Hirano M, Egli D |
|---|---|
| Journal | Cell Stem Cell |
| Publication Date | 01 May 2016 |
| Research Area(s) include | Stem Cell Biology |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Dermal Fibroblasts, hPSC |
| Cell Type(s) include | Fibroblast, Stem cells |
| Species | Human |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | 7.0x10^4 cells/well |
| Plate Coating | Not Specified |
- Journal: Elife
- Publication Date: 10 July 2017
- Author: Wang X , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
| Authors | Wang X, Zhang X, Wu D, Huang Z, Hou T, Jian C, Yu P, Lu F, Zhang R, Sun T, Li J, Qi W, Wang Y, Gao F, Cheng H |
|---|---|
| Journal | Elife |
| Publication Date | 10 July 2017 |
| Research Area(s) include | Cardiovascular Research |
| Technique | Seahorse XF Technology |
| Analyzer(s) include | Seahorse XFe24/XF24 |
| Cell Line(s) include | Cardiomyocytes |
| Cell Type(s) include | Cardiac cells |
| Species | Mouse |
| Assay / Method | Cell Mitochondrial Stress Test |
| Cell Seeding Density | Not Specified |
| Plate Coating | Not Specified |