Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Services
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
-
Instrument
- Method
- Outer DIameter
-
Outer DIameter
- Unit Quantity
-
Unit Quantity
- Analysis Platform
-
Analysis Platform
- Spectroscopy Instrument Compatibility
-
Spectroscopy Instrument Compatibility
- Language
-
Language
The analysis of used engine oils by spectrometric techniques for the early detection of machine component failure...
- Publication Part Number: SI-A-1230
- Created: 27 Sep 2012
- 291 KB
Describes the use of graphite furnace Atomic Absorption to determine the levels of aluminum in natural waters affected by acid rain.
- Publication Part Number: SI-A-1214
- Created: 27 Sep 2012
- 43 KB
Presenting the benefits of routine maintenance of atomic absorption spectrophotometers, including general instrument, gas supply, and furnace maintenance.
- Publication Part Number: SI-A-1213
- Created: 27 Sep 2012
- 85 KB
Examines using the GTA-95 to determine levels of vanadium in industrial fuel oil. Using air as an ashing aid to reduce matrix interferences was investigated.
- Publication Part Number: SI-A-1210
- Created: 27 Sep 2012
- 200 KB
Hydride generation techniques are used routinely for the determination of As, Se, and Sb in environmental samples...
- Publication Part Number: SI-A-1299
- Created: 26 Sep 2012
- 63 KB
Hollow cathode lamps are an essential component of an atomic absorption (AA) analysis...
- Publication Part Number: SI-A-1367
- Created: 26 Sep 2012
- 1 MB
Using tetralin as a diluent and scandium as an internal reference, learn to determine vanadium, nickel, and iron in crude oils and residua by ICP-OES.
- Publication Part Number: SI-A-1417
- Created: 25 Sep 2012
- 529 KB
Explains causes of curvature in AA calibration graphs, including ionization, chemical interference, unresolved multiplets, nonabsorbed lines, stray light, and more.
- Publication Part Number: SI-A-1360
- Created: 25 Sep 2012
- 207 KB
490-GC can be used for analyses of mine gas, especially carbon monoxide at low level which is essential for the safety of mine workers.
- Publication Part Number: SI-02235
- Created: 06 Sep 2012
- 642 KB
| Publication Part Number | SI-02235 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The 8800 Triple Quadrupole ICP-MS operating with a single acquisition method to successfully to measure all REE impurities in high-purity REE materials.
- Publication Part Number: 5991-0892EN
- Created: 14 Aug 2012
- 272 KB
Application note for Direct analysis of Cr, Ni, Pb and V in ethanol fuel by Microwave Plasma-Atomic Emission Spectrometry
- Publication Part Number: 5991-0771EN
- Created: 03 Aug 2012
- 152 KB
| Publication Part Number | 5991-0771EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Portuguese (Brazil) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
A multi-residue pesticides analysis method by GC/MS/MS was evaluated for trace analysis of 33 representative pesticides in six different plantation food matrices.
- Publication Part Number: 5990-9317EN
- Created: 04 Nov 2011
- 912 KB
| Publication Part Number | 5990-9317EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column separates fatty acid ethylene glycol esters in a sample of montan wax in 36 minutes.
- Publication Part Number: A01386
- Created: 31 Oct 2011
- 569 KB
| Publication Part Number | A01386 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC with Agilent J&W CP-SilicaPLOT analyzes sulfur (to about 0.05 to 0.1 ppm) and hydrocarbosn in beverage-grade CO2; aromatic and acetaldehyde hydrocarbons < 1 ppbv.
- Publication Part Number: A01644
- Created: 31 Oct 2011
- 385 KB
| Publication Part Number | A01644 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for the determination of low levels of arsenic using flame AAS and UltrAA lamps
- Publication Part Number: SI-A-1366
- Created: 01 Nov 2010
- 59 KB
Application note for a rapid method for trace analysis of organophosphorus pesticides in drinking water
- Publication Part Number: 5990-3158EN
- Created: 13 Nov 2008
- 118 KB
Application note for unmatched spectral interference removal in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode
- Publication Part Number: 5989-4905EN
- Created: 23 Mar 2006
- 159 KB
A financial model has been developed to help the metals laboratory using GFAA and ICP-OES calculate the potential savings by switching to ICP-MS.
- Publication Part Number: 5989-1585EN
- Created: 17 Jan 2005
- 435 KB
Application note for using a new gas phase micro-fluidic deans wwitch for the 2-D GC analysis of trace methanol in crude oil
- Publication Part Number: 5989-1840EN
- Created: 03 Nov 2004
- 678 KB
A large percentage of rubies and sapphires undergo some degree of heat treatment to enhance their color and, as a result, to increase their value.
- Publication Part Number: 5989-1266EN
- Created: 13 July 2004
- 490 KB