Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Services
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
-
Instrument
- Method
- Outer DIameter
-
Outer DIameter
- Unit Quantity
-
Unit Quantity
- Analysis Platform
-
Analysis Platform
- Spectroscopy Instrument Compatibility
-
Spectroscopy Instrument Compatibility
- Language
-
Language
Agilent J&W Ultimate Plus fused silica tubing outperformed other tubing for semivolatiles, especially for highly active compounds sensitive to an inert flow path.
- Publication Part Number: 5991-5441EN
- Created: 17 Dec 2014
- 248 KB
Agilent J&W Ultimate Plus fused silica tubing outperformed competitor tubing for pesticides, especially for highly active compounds sensitive to an inert flow path.
- Publication Part Number: 5991-5404EN
- Created: 05 Dec 2014
- 305 KB
Agilent Ultimate Plus deactivated silica tubing outperformed another supplier’s tubing overall for inertness, mechanical strength, and thermal stability.
- Publication Part Number: 5991-5142EN
- Created: 05 Sep 2014
- 2 MB
Application note for on-line isotope dilution analysis with the 7700 Series ICP-MS: Analysis of trace elements in high matrix samples
- Publication Part Number: 5990-9171EN
- Created: 13 Feb 2014
- 118 KB
Application note for low-level speciated analysis of Cr(III) and Cr(VI) using LC(IC)-ICP-MS
- Publication Part Number: 5990-9366EN
- Created: 13 Feb 2014
- 259 KB
| Publication Part Number | 5990-9366EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for new methodology for determination of gold and precious metals
- Publication Part Number: 5990-8597EN
- Created: 12 Feb 2014
- 392 KB
| Publication Part Number | 5990-8597EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Application note for the determination of magnesium, calcium and potassium in brines by flame AAS using the SIPS-10 accessory
- Publication Part Number: SI-A-1357
- Created: 03 Feb 2014
- 155 KB
Application note for the sensitivity enhancement for flame atomic absorption spectrometry using an ACT 80 atom concentrator tube.
- Publication Part Number: SI-A-1292
- Created: 03 Feb 2014
- 331 KB
Guidelines for using non-aqueous solvents in AA Spectrometry, including safety aspects, standards, calculations, ionic suppressants, hardware and graphite furnace operation
- Publication Part Number: SI-A-1294
- Created: 30 Jan 2014
- 49 KB
Atomic absorption spectrophotometers make it relatively easy to obtain analytical results which are consistently accurate and precise..
- Publication Part Number: SI-A-1158
- Created: 28 Jan 2014
- 61 KB
Application note for the determination of lead in unleaded gasoline using the SpectrAA 55 atomic absorption spectrophotometer
- Publication Part Number: SI-A-1139
- Created: 27 Jan 2014
- 38 KB
Self-tightening GC column nuts are easily removed after use and maintain a leak-free seal over more than 300 injections, without need for retightening.
- Publication Part Number: 5991-3612EN
- Created: 20 Nov 2013
- 501 KB
| Publication Part Number | 5991-3612EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Inter-laboratory validation study on detection of Trace-Level Herbicides in Drinking, Surface and Ground Water Using the Agilent 1200 Infinity Series Online SPE Solution
- Publication Part Number: 5991-2405EN
- Created: 01 June 2013
- 821 KB
| Publication Part Number | 5991-2405EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology
- Publication Part Number: 5991-0876EN
- Created: 17 Apr 2013
- 407 KB
| Publication Part Number | 5991-0876EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
A detailed look at eleven well known flammable solvents used in flame AA and how to select the best one for your experiment, keeping safety as your top priority.
- Publication Part Number: SI-A-1155
- Created: 13 Nov 2012
- 36 KB
Regulations and methodology for measuring trace metal environmental pollutants, especially in drinking water, industrial effluents, and hazardous wastes.
- Publication Part Number: SI-A-1208
- Created: 12 Nov 2012
- 71 KB
Rinse water used in the production of integrated electronic chips can be tested for trace elements by Graphite Furnace AA.
- Publication Part Number: SI-A-1108
- Created: 12 Nov 2012
- 91 KB
The measurement of trace metal levels in environmental waters is ideally performed by atomic absorption spectroscopy, and the literature...
- Publication Part Number: SI-A-1248
- Created: 28 Sep 2012
- 210 KB
Describes results achieved with flame AA and furnace AA for the direct determination of phosphorus in aqueous matrices.
- Publication Part Number: SI-A-1209
- Created: 28 Sep 2012
- 227 KB
Describes a method using Zeeman graphite furnace atomic absorption spectrometry for the determination of trace elements (As, Cu, Pb) in seawater samples.
- Publication Part Number: SI-A-1106
- Created: 28 Sep 2012
- 85 KB