Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Services
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
-
Instrument
- Method
-
- Agency Method
-
Agency Method
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Outer DIameter
-
Outer DIameter
- Packaging
-
Packaging
- Model
-
Model
- Solvent
-
Solvent
- Analyte
-
Analyte
- CAS Number
-
CAS Number
- Concentration
-
Concentration
- Format
-
Format
- Technique
-
Technique
- Unit Quantity
-
Unit Quantity
- Volume
-
Volume
- Analysis Platform
-
Analysis Platform
- MS Instrument Compatibility
-
MS Instrument Compatibility
- Spectroscopy Instrument Compatibility
-
Spectroscopy Instrument Compatibility
- Language
-
Language
Need help finding the right ICP supplies? Try our ICP Supplies Selector Tool.
Sample loop, Easy-fit, 4.00 mL volume, 645s acq. time, 2.18 mm id. Provides a typical acquisition time of 645 seconds when used for ICP-MS with ISIS 3, peristaltic pump and SPS4. Compatible with AVS MS.
-
Volume:
4 mL
-
Unit:
1 Each

Sample loop, for AVS, 0.25 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7 and AVS MS (formerly ISIS 3) on ICP-OES and ICP-MS. Replacement for p/n 5005-0030 and p/n G8010-60338.
-
Volume:
0.25 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 0.50 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n 5005-0031 and p/n G8010-60339.
-
Volume:
0.50 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 0.75 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n 5005-0032.
-
Volume:
0.75 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 1.00 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n 5005-0033 and p/n G8010-60305.
-
Volume:
1.00 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 1.25 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n 5005-0034.
-
Volume:
1.25 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 1.50 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n 5005-0035 and p/n G8010-60340.
-
Volume:
1.50 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 2.00 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n 5005-0036 and p/n G8010-60341.
-
Volume:
2.00 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 2.50 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n 5005-0037 and p/n G8010-60342.
-
Volume:
2.50 mL
-
Unit:
1 Pack

Sample loop, for ADS/AVS, 3.00 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7, AVS MS (formerly ISIS 3) and ADS 2 on ICP-OES and ICP-MS. Replacement for p/n G8010-60343.
-
Volume:
3.00 mL
-
Unit:
1 Pack

Sample loop, for AVS, 3.50 mL, 1.00 mm id, 1/pk. Recommended for use with AVS 6/7 and AVS MS (formerly ISIS 3) on ICP-OES and ICP-MS. Replacement for p/n G8010-60344.
-
Volume:
3.50 mL
-
Unit:
1 Pack

Replacement gas line and fitting for Mira Mist nebulizer, 1/pk. Contains 2 mm gas line with UpChurch fittings and 4 mm adaptor for Mira Mist nebulizers for Agilent ICP-OES and ICP-MS instruments.
-
Unit:
1 Pack

Peristaltic pump tubing for ISIS-DS, PVC, 2-stop, black/purple tabs, 2.29 mm id, 1 pack of 12 pcs. For use with ISIS-DS on Agilent 7500, 7700, 8800 ICP-MS.
-
Unit:
12 Each

Peristaltic pump tubing for ISIS-DS, PVC Tygon®, 3-stop, orange/orange tabs, 0.89 mm id, 1 pack of 12 pcs. For use with ISIS-DS on Agilent 7500, 7700, 8800 ICP-MS
-
Unit:
12 Each

Peristaltic pump tubing for ISIS-DS, PVC Tygon®, 2-stop, orange/blue tabs, 0.25 mm id, 1 pack of 12 pcs. For use with ISIS-DS on Agilent 7500, 7700, 8800 ICP-MS
-
Unit:
12 Each

ISIS-DS, Sample tubing, PTFE, 0.8 mm id, 1.6 mm od, 5 m length. Suitable for ISIS-DS used with Agilent 7500 ICP-MS
-
Unit:
1 Each

ISIS-DS, Sample tubing, PTFE, 2 mm id, 3 mm od, 5 m length. Suitable for ISIS-DS used with Agilent 7500 ICP-MS
-
Unit:
1 Each

Adapter for peristaltic pump tubing connection to sample tubing, used on ISIS-DS, 1 pack of 2 pcs. For use with ISIS-DS on Agilent 7500, 7700, 8800 ICP-MS
-
Unit:
2 Each

ISIS-DS tubing clamp, small 1 pack of 10 pieces, large 1 pack of 5 pieces. For use with ISIS-DS on Agilent 7500, 7700, 8800 ICP-MS
-
Unit:
15 Each

Peristaltic pump tubing for ISIS-DS, PVC Tygon®, 2-stop, white/white tabs, 1.02 mm id, 1 pack of 12 pcs. For use with ISIS-DS on Agilent 7500, 7700, 8800 ICP-MS
-
Unit:
12 Each
