Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Services
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
-
- Instrument
-
Instrument
- Method
-
- Agency Method
-
Agency Method
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Outer DIameter
-
Outer DIameter
- Packaging
-
Packaging
- Model
-
Model
- Solvent
-
Solvent
- Analyte
-
Analyte
- CAS Number
-
CAS Number
- Concentration
-
Concentration
- Format
-
Format
- Technique
-
Technique
- Unit Quantity
-
Unit Quantity
- Volume
-
Volume
- Analysis Platform
-
Analysis Platform
- MS Instrument Compatibility
-
MS Instrument Compatibility
- Spectroscopy Instrument Compatibility
-
Spectroscopy Instrument Compatibility
- Language
-
Language
Need help finding the right ICP supplies? Try our ICP Supplies Selector Tool.
Sample Tray F for Agilent Integrated Autosampler (I-AS), with 15 positions for 48 mm od vials. Polypropylene (PP) sample rack. Order suitable 48 mm od x 55 mm tall vials seperately. Ideal for use in semi-conductor applications.
-
Unit:
1 Each

Sample Tray G for Agilent integrated autosampler (I-AS), with 28 positions for 20 mL PFA vials up to 28 mm od x 58 mm tall. Polypropylene (PP) sample rack. Order 20 mL PFA vials up to 28 mm od x 58 mm tall seperately. Ideal for use in...
-
Unit:
1 Each

Sample uptake tube and connector, EzyFit, 0.25 mm id, 700 mm capillary, for MicroMist concentric nebulizer, 10/pk. Optional narrow id sample capillary, suitable for all Agilent ICP-MS using the EzyFit MicroMist nebulizer
-
Unit:
10 Each

Sample uptake tube and connector, EzyFit, 0.5 mm id, 700 mm capillary, for MicroMist concentric nebulizer, 10/pk. Standard on 7700 and 8800 ICP-MS, suitable for all Agilent ICP-MS using the EzyFit MicroMist nebulizer
-
Unit:
10 Each

Sample uptake tube and connector, UniFit, 0.5 mm id, with 0.5 mm id x 700 mm capillary, for U-Series MicroMist concentric nebulizer, 10/pk. Standard on 7800, 7850 and 7900 ICP-MS, suitable for all Agilent ICP-MS using the U-series MicroMist...
-
Unit:
10 Each

Sample uptake tube and connector, UniFit, 0.25 mm id, with 0.25 mm id x 700 mm capillary, for U-Series MicroMist concentric nebulizer, 10/pk. Optional narrow id sample capillary, suitable for all Agilent ICP-MS using the U-series MicroMist nebulizer
-
Unit:
10 Each

ORS cell gas tubing, stainless steel, 1/8 in od, 6 m. For supply connection of Helium, Hydrogen or reaction gas from regulator to instrument. Recommended to purchase tubing cutter 8710-1709 for installation.
-
Unit:
1 Each

Quartz connector from spray chamber to torch with dilution port for high matrix introduction (HMI). Suitable for use with all Agilent ICP-MS including with HMI aerosol dilution 7500, 7700, 7800, 7850 and 8800
-
Unit:
1 Each

Quartz connector from spray chamber to torch, without gas port. Suitable for use with all Agilent ICP-MS including 7850, 7900, 8900 with UHMI and 7500, 7700, 7800, 8800 without HMI aerosol dilution
-
Unit:
1 Each

Drain Tubing for aqueous waste, PVC Tygon®, 3 mm id, 6 mm OD, 3 m length per unit. Suitable for use for aqueous samples from spray chamber drain peristaltic pump tubing or Autosampler drain to waste vessel. Used with all Agilent ICP-MS models.
-
Unit:
1 Each

Quartz Spray chamber, Scott double-pass, standard for Agilent 7500, 7700, 7800 and 8800. For use with HMI or no aerosol gas dilution. Also suits 7850 / 7900 / 8900 if UHMI capability is not required. Requires end cap p/n G3280-60008.
-
Unit:
1 Each

Quartz Spray chamber with fixed connector to torch, Scott double-pass, recommended for ultra-trace analysis of Boron. For use without aerosol gas dilution, not compatible with HMI or UHMI. Optional on all Agilent ICP-MS. Requires End Cap...
-
Unit:
1 Each

Injector, sapphire, 2.5 mm id, for PFA inert kit, for aqueous samples. Replacement for PFA inert sample introduction kit with Agilent 7500, 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS
-
Unit:
1 Each

Injector, platinum, 2.5 mm id, for PFA inert kit, for aqueous samples in semiconductor applications. Replacement for PFA inert sample introduction kit with Agilent 7500, 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS
-
Unit:
1 Each

Sample probe, carbon fiber, 1.0 mm id (2 blue bands), for ASX 500 autosampler. Suitable for use with Agilent ICP-MS systems supported by MassHunter software.
-
Unit:
1 Each

Semi-demountable inert torch for PFA inert kit, used with 2.5mm id sapphire or platinum injector for aqueous applications. Replacement outer quartz torch body for PFA inert sample introduction kit suitable for Agilent 7500, 7700, 7800, 7850, 7900,...
-
Unit:
1 Each

Semi-demountable inert torch for PFA inert kit, used with 1.5mm id sapphire or platinum injector for organic applications. Replacement outer quartz torch body for PFA inert sample introduction kit suitable for Agilent 7500, 7700, 7800, 7850, 7900,...
-
Unit:
1 Each

Compare
Compare
ICH/USP oral target elements standard C, Au, Ir, Os, Pd, Pt, Rh, and Ru 100 µg/mL in 15 % HCl. Obsolete - Please order replacement part number = 5191-4555
-
Volume:
100 mL
-
Unit:
1 Each