Refine Results
- Products
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
-
- Instrument
- Agency Method
-
Agency Method
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Unit Quantity
-
Unit Quantity
- Analysis Platform
-
Analysis Platform
- Language
-
Language
Analysis of low levels of bromochloromethane in chloroform is done by GC/MS with Agilent J&W PoraBOND Q columns in 12 minutes.
- Publication Part Number: A01919
- Created: 01 Oct 2011
- 631 KB
| Publication Part Number | A01919 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Gas chromatography with the Agilent J&W PoraBOND Q column four chlorinated solvents in under 13 minutes.
- Publication Part Number: A01905
- Created: 01 Oct 2011
- 698 KB
| Publication Part Number | A01905 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with the Agilent J&W PoraBOND Q separates eight substituted benzenes and MTBE in 23 minutes.
- Publication Part Number: A01904
- Created: 01 Oct 2011
- 996 KB
| Publication Part Number | A01904 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Using a headspace technique it is possible to measure ppb levels of volatile furan in different matrices with the Agilent J&W PoraBOND Q column.
- Publication Part Number: A02391
- Created: 11 May 2010
- 597 KB
| Publication Part Number | A02391 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
An Agilent7820 GC method for Acetaldehyde residue in PET bottled was developed .
- Publication Part Number: 5991-4355EN
- Created: 28 Mar 2014
- 120 KB
| Publication Part Number | 5991-4355EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Agilent J&W PLOT PT column installation and user guide.
- Created: 26 July 2013
- 1 MB
A porous polymer PLOT stationary phase for analysis of polar and apolar volatile compounds, and water as an analyte.
Provides excellent peak symmetry and retention time repeatability with polar and nonpolar volatiles.
A divinylbenzene/vinylpyridine polymer PLOT column for analysis of medium polarity volatiles, including hydrocarbons and ketones.
Agilent J&W PoraBOND Q PT and CP-Molsieve 5Å PT columns resolve permanent gases and light hydrocarbons by GC/TCD with helium and argon and no particle shedding.
- Publication Part Number: 5991-4873EN
- Created: 24 June 2014
- 419 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
GC analysis of permanent gases and CO2 is achieved in less than 10 minutes using Agilent PLOT columns in tandem, with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02028
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A02028 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Fast GC analysis of permanent gases and CO2 is achieved in two minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02050
- Created: 31 Oct 2011
- 845 KB
| Publication Part Number | A02050 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of permanent gases and CO2 is achieved in less than five minutes using Agilent PLOT columns in tandem,with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02030
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A02030 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of permanent gases and CO2 is achieved in only 3.5 minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02017
- Created: 31 Oct 2011
- 780 KB
| Publication Part Number | A02017 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Fast GC of five permanent gases and CO2 is achieved in less than three minutes using Agilent PLOT columns in tandem,with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02032
- Created: 31 Oct 2011
- 447 KB
| Publication Part Number | A02032 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of permanent gases and CO2 is achieved in less than 20 minutes using Agilent PLOT columns in tandem, with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02031
- Created: 31 Oct 2011
- 616 KB
| Publication Part Number | A02031 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
For your first step in food safety analysis, start with Agilent Bond Elut QuEChERS sample preparation products. See wide range of new, apps featuring the QuEChERS approach.
- Publication Part Number: 5990-4977EN
- Created: 21 Mar 2013
- 9 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
| Japanese (Japan) | Complete (PDF) |
Agilent PoraPLOT U channels for the 990 Micro GC are ideal for hydrocarbon separations C1 to C6, halocarbons/freons, anesthesia gases, sulfur gases (H2S/COS), CO2, and volatile solvents.
- Publication Part Number: 5994-7300EN
- Created: 26 May 2026
- 129 KB
Agilent J&W CP-COX channels are micro packed, carbon-based column channels that can separate both carbon monoxide and carbon dioxide in permanent gas-type mixtures.
- Publication Part Number: 5994-7603EN
- Created: 26 May 2026
- 126 KB
Agilent J&W CP-PoraPLOT Q channels for the 990 Micro GC are ideal for hydrocarbon separations C1 to C6, halocarbons/freons, anesthesia gases, sulfur gases H2S/COS, CO2 , and volatile solvents.
- Publication Part Number: 5994-7476EN
- Created: 21 May 2024
- 105 KB