Before installing this software please read this Pre-install Notice:
ICP-MS ChemStation Rev. B.03.05
Installation of B.03.05
- Prior to clicking the link to download the update patch to B.03.05, please open the ChemStation Install Guide for B.03.05. This is a PDF file and it is recommended that you save and print a copy and refer to it during installation of B.03.05. The Install Guide includes important information for proper installation of the update patch (including the need to shut down the ICP-MS system).
- The features new to B.03.05 are briefly highlighted below. In order to take full advantage of B.03.05 and learn its features, please refer to the latest version of the Agilent 7500 Series ICP-MS ChemStation (G1834B) Operator’s Manual. In the event you are using supported peripherals (such as autosampler or HMI kit); please read the manuals which came with the peripherals.
The P/N for the version of the Operator's Manual published in conjunction with the release of B.03.05 is:
G3270-90114
A copy can be ordered by contacting your Agilent representative. After installation of B.03.05 please also refer to the online help for assistance in using the software.
Additional Information:
- New features of Rev.B.03.05
- System Requirements
- Compatibilities
New Features of Rev.B.03.05
The following features and changes provided.
- Agilent 7500cx is supported. It is possible to configure and control Agilent 7500cx.
- Aerosol Control option is supported. ICP-MS ChemStation provides 'Aerosol Control' feature to Agilent 7500cx with installed HMI kit. You can set plasma conditions for high matrix samples easily by using the 'Aerosol Control' feature.
- CETAC EXR-8 autosampler is supported. It is possible to configure and control the CETAC EXR-8 auto sampler.
- Evacuation Assist Valve is supported. It is possible to control the Evacuation Assist Valve.
System Requirements
Following are the system requirements for Rev.B.03.05 or later.
1. PC: HP Compaq d510SFF Pentium4 2.4GHz or faster
2. System Memory: 512MB of RAM or greater
3. Hard Disk: 80GB or greater
4. OS: Windows XP Professional + Service Pack 2
5. Internet Explorer: Internet Explorer 6 + Service Pack 1
6. Printer: HP LaserJet 4000, HP LaserJet 4050 or HP LaserJet 2200
Notice: Printers shipped with ChemStation PC after release of Rev. B.01.01 also supported.
7. I/O Libraries: ver.M.01.01.04
8. Supported Instrument: Agilent 7500 LAN model
Compatibilities
The following is the list of file compatibilities between G1834B Rev.B.03.05 and the previous release (G1834B, Rev.B.03.04).
| Methods |
same |
| Calibration |
same |
| Data |
same |
| Tune |
same |
| Sequence |
same |
| Chained Sequence |
same |
| Report Template |
same |
| QC Mode |
same |