Agilent J&W GC Columns

Agilent J&W’s integrated PLOT PT columns are engineered to improve lab operations. Unlike current techniques utilized to reduce PLOT stationary phase particles from flowing downstream from the column, Agilent’s new PLOT columns with integrated particle traps eliminate the hassle of connecting separate particle traps for convenient leak free operation with no worries.

Features:

  • Enhance analytical capability in the lab using PLOT analyses with MS detection and Capillary Flow Technology (CFT).
  • No more hassles with unions or downstream filters: Our integrated particle trapping technology is incorporated into the column as one continuous length of fused silica tubing.
  • Higher throughput: Reproducible flow restriction and increased stability reduce the need for method/system adjustments, and promote a steadier analytical output.
  • Lower operating costs and less downtime associated with replacing filters and column switching valves.

The integrated particle trapping technology on both ends of Agilent J&W PLOT PT GC columns reduces downtime, while allowing you to use a GC/MS for detailed, qualitative and quantitative analysis. No other PLOT column offers this level of worry-free operation of your GC or GC/MS system.

PLOT PT GC columns flyer (5991-1174EN)

Ordering Information

Part Number Description Dimensions
CP7550 PT PoraPLOT Q PT 10 m x 0.32 mm
CP7551 PT PoraPLOT Q PT 25 m x 0.32 mm
CP7554 PT PoraPLOT Q PT 25 m x 0.5 mm
CP7557 PT PoraPLOT Q-HT PT 5 m x 0.32 mm
19091P-QO3 PT HP-PLOT Q PT 0.32 mm x 15 m, 20 μm
19091P-QO4 PT HP-PLOT Q PT 0.32 mm x 30 m, 20 μm
19095P-QO3 PT HP-PLOT Q PT 0.53 mm x 15 m, 40 μm
19095P-QO4 PT HP-PLOT Q PT 0.53 mm x 30 m, 40 μm
19095P-UO4 PT HP-PLOT U 0.53 mm x 30 m, 20 μm
CP7579 PT PoraPLOT U PT 25 m x 0.25 mm
CP7584 PT PoraPLOT U PT 25 m x 0.53 mm, 20 μm
CP7348 PT CP-PoraBOND Q PT 25 m x 0.25 mm
CP7351 PT CP-PoraBOND Q PT 25 m x 0.32 mm
CP7352 PT CP-PoraBOND Q PT 50 m x 0.32 mm
CP7354 PT CP-PoraBOND Q PT 25 m x 0.53 mm
115-3432 PT GS-Q PT 30 m x 0.53 mm

Now you can confidently use PLOT columns for GC/MS applications

Agilent J&W PLOT PT GC columns are the only PLOT columns stabilized with integrated particle trapping technology on both ends to virtually eliminate particle shedding. They are ideal for analyzing light gases, solvents, and other volatile organic compounds in HPI, environmental (air), forensic, and food applications. And they are brought to you by Agilent – the world’s GC leader.


Column: PoraBond Q PT, 30 m×0.25 mm, 3 µm
Part No. CP7348PT
Carrier: Helium, 43 cm/s @ 90 ºC
Oven: 90 °C - 140 °C at 10 °C/min 
            140 °C for 6 min 
            140 °C - 200 °C at 5 °C/min 
             200 °C for 10 min
Injection: Split, 250 ºC, split ratio 1:160
Detector: MSD, 280 ºC Transfer line, full Scan  at m/z 30-350

1. Methyl Alcohol
2. Acetaldehyde
3. Ethanol
4. Acetonitrile
5. Acetone
6. Methylene Chloride
7. Isopropyl Alcohol
8. 2-Propanamine
9. Ethyl Formate
10. 1-Propanol
11. Ethyl ether
12. t-Butyl alcohol
13. 1,2-Ethanediol
14. Trichloromethane

15. 2-Butanone (MEK)
16. Ethyl Acetate
17. sec-Butyl alcohol
18. MTBE
19. 2-chlorobutane
20. 1-Butanol
21. Benzene
22. 1,1,1-Trichloroethane
23. 1-chlorobutane
24. Carbon Tetrachloride
25. Hexane
26. 1,4-Dioxane
27. Pyridine
28. Dimethyl Formamide (DMF)
29. Isoamyl Alcohol
30. Dimethyl Sulfoxide (DMSO)
31. Toluene
32. Heptane
33. Paraldehyde
34. Chlorobenzene
35. Ethylbenzene
36. m-Xylene
37. p-Xylene
38. o-xylene