Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
- Instrument
-
- Analysis Platform
-
Analysis Platform
- Language
-
Language
This application note uses Agilent QuEChERS kits for fast sample preparation, resulting in excellent pesticide recoveries. Extraction efficiency with high recoveries was achieved for over 200 pesticides in tomatoes on the Agilent 7000D GC/TQ.
- Publication Part Number: 5994-4384EN
- Created: 23 Jan 2023
- 858 KB
This application note focuses on the quantitation of over 100 pesticides in kale by GC/MS/MS and the Agilent Bond Elut QuEChERS High Pigment dSPE with Carbon S.
- Publication Part Number: 5994-5108EN
- Created: 06 July 2022
- 2 MB
This application note presents the validation of a multiresidue method for the analysis of planar pesticide residues in tomato and kale.
- Publication Part Number: 5994-5050EN
- Created: 24 June 2022
- 958 KB
This application note presents the development and validation of a multiresidue method for the analysis of pesticide residues in blackberry, blueberry and raspberry.
- Publication Part Number: 5994-4764EN
- Created: 19 May 2022
- 1 MB
This application note evaluates sample preparation using Captiva EMR–GPF cleanup for the analysis of 230 pesticides in a bell pepper mix using LC/MS/MS or GC/MS/MS.
- Publication Part Number: 5994-4767EN
- Created: 19 May 2022
- 1 MB
Lower your detection limits and quantify active analysts with confidence with Agilent Inert Flow Path solutions.
- Publication Part Number: 5990-8532EN
- Created: 26 Jan 2021
- 3 MB
GC/MS brochure highlighting the specific benefits of Agilent columns and supplies to support the entire workflow from sample preparation to separation for the GC/MS platform. This brochure includes several charts helping the customer get started on...
- Publication Part Number: 5989-9972EN
- Created: 28 Jan 2020
- 1 MB
This note describes the quantitative analysis of pesticide residue in bovine milk listed on brazilian national plan and codex alimentarius.
- Publication Part Number: 5991-6916EN
- Created: 04 May 2016
- 295 KB
Agilent Flexible Metal Ferrules were better than Siltite ferrules for benzodiazepine peak shape and response by FID.
- Publication Part Number: 5991-1859EN
- Created: 25 Aug 2015
- 1 MB
| Publication Part Number | 5991-1859EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
A modified Bond Elut QuEChERS method was validated for the extraction of 27 pesticide residues from a high lipid olive matrix prior to GC/MS/MS.
- Publication Part Number: 5991-4800EN
- Created: 18 June 2014
- 316 KB
| Publication Part Number | 5991-4800EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
A gas chromatography-triple quadrupole mass spectrometer (GC-MS/MS) method
- Publication Part Number: 5991-4434EN
- Created: 15 Apr 2014
- 698 KB
| Publication Part Number | 5991-4434EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Flow path inertness is critical in pesticide analysis for accuracy and precision
- Publication Part Number: 5991-1862EN
- Created: 21 Mar 2013
- 779 KB
| Publication Part Number | 5991-1862EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Flow path inertness is critical in pesticide analysis accuracy and precision, especially for active analytes such as organophosphate pesticides.
- Publication Part Number: 5991-1860EN
- Created: 13 Mar 2013
- 1 MB
| Publication Part Number | 5991-1860EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The QuEChERS method for pesticide analysis was first introduced by USDA scientists in 2003...
- Publication Part Number: 5990-8108EN
- Created: 16 May 2011
- 142 KB
| Publication Part Number | 5990-8108EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Application note for semivolatile organics analysis using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column
- Publication Part Number: 5990-3416EN
- Created: 20 Jan 2009
- 317 KB
GC troubleshooting guide: solving common problems and staying productive.
- Publication Part Number: 5994-0451EN
- Created: 16 Feb 2023
- 776 KB
In this quick reference guide, you’ll find USP codes for the GC phases used in USP methods, and tips for selecting the right stationary phase.
- Publication Part Number: 5994-4527EN
- Created: 24 Jan 2022
- 248 KB