Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
- Instrument
-
- Analysis Platform
-
Analysis Platform
- Language
-
Language
Instructions for using polyimide sealing resin with glass press-fit unions
mAb titer for process development (or purification of small amounts of mAb for further characterization fast separation)
Agilent Technologies offers Ultra Inert universal press-fit column connectors
A selection of ergonomically designed manual vial crimpers, vial decappers, and related accessories.
Compare
For automated protein sample preparation using verified protocols
HPLC - Carbohydrate Analyses in LC
HPLC - Carbohydrate Analyses in LC
-
INTRODUCTION Columns for carbohydrate separations use different chromatographical partitioning techniques, which separate molecules based on a number of different chemical characteristics. The most common mechanism is Ion-Exclusion Partition Chromatography (IEPC) or Ion-Moderated Partition Chromatography (IMPC). The resin is a polystyrene-divinylbenzene co-polymer with bonded propyl benzenesulfonic acid groups, which can be loaded with a cation (sodium, calcium, lead). The negatively charged sulfonic acid groups and the positively charge metal ions form a kind of semi permeable membrane, which repels ionic species, but is permeable for neutral ones. The eluent in the resin is the second (stationary) phase and neutrals part between the eluent and the "resin-eluent". This partitioning is stimulated for carbohydrates by ligand exchange effects (see below).
Chromosorb - Properties of the Most Used Support Material in Packed GC
Chromosorb - Properties of the Most Used Support Material in Packed GC
-
Introduction In Packed Gas Chromatography liquid phases need a support material as carrier. This support is mainly d iatomaceous earth, i. e. fossilized shells of very small sea life from millions of years ago.
Application note for resin analysis with Agilent PLgel MIXED Columns and Gel Permeation Chromatography
- Publication Part Number: 5990-8416EN
- Created: 30 Apr 2015
- 385 KB
| Publication Part Number | 5990-8416EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Phenol formaldehyde resins are made by the reaction of phenol and formaldehyde, through...
- Publication Part Number: 5990-8486EN
- Created: 30 Apr 2015
- 183 KB
| Publication Part Number | 5990-8486EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GS
- Publication Part Number: 5990-8419EN
- Created: 30 Apr 2015
- 159 KB
| Publication Part Number | 5990-8419EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for the analysis of Epoxy Resins by GPC Viscometry using the 390-LC Multi Detector Suite (MDS)
- Publication Part Number: 5991-5840EN
- Created: 30 Apr 2015
- 777 KB
Determination of Epoxy Resin Polymers by GPC with the Agilent 1290 Infinity II LC Equipped with the Agilent 1290 Infinity II RID
- Publication Part Number: 5994-1547EN
- Created: 11 Nov 2019
- 390 KB
This study establishes HRMS as a critical tool for dissecting the complex structure information of ArF photoresist resins.
- Publication Part Number: ASMS 2025 Poster ThP 748
- Created: 15 May 2025
- 414 KB
Column for organic GPC/SEC of polar polymers with polar organic solvents, such as DMF or DMSO
Specialist design of a suitable, optimized method that aligns with your project goals
High density non-porous weak cation exchanger for mAb charge variant analysis.
Compare
High resolution with high throughput for reduced costs at micro- or analytical-scale operation.
An OpenLAB CDS add-on for application-specific GPC/SEC calibration, data processing, and reporting
Polar modified silica-based column for GPC/SEC of polymers in polar organics such as DMAc and DMSO
Styrene-divinylbenzene copolymer-based column for organic GPC/SEC analysis of polymers
Fully porous quaternary amine strong anion-exchange suitable for oligonucleotides and proteins.