Refine Results
- Products
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
- Compounds
-
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Particle Size
-
Particle Size
- Unit Quantity
-
Unit Quantity
- LC Column Brand
-
LC Column Brand
- LC Column Maximum Temperature
-
LC Column Maximum Temperature
- Molecular Weight Lower Limit
-
Molecular Weight Lower Limit
- Molecular Weight Upper Limit
-
Molecular Weight Upper Limit
- Analysis Platform
-
Product
- Language
-
Language
Compare
OligoPore, 7.5 x 50 mm, 6 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 6µm OligoPore analytical columns 7.5 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
OligoPore, 7.5 x 300 mm, 6 µm. Multipore GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 3.3 kDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
OligoPore, 25 x 300 mm, 6 µm. Multipore GPC/SEC preparative column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to separate non-polar polymers resolving range 100 Da to 3.3 kDa
-
Unit:
1 Each
-
Length:
300 mm

Compare
OligoPore, 4.6 x 50 mm, 6 µm, guard. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 6µm OligoPore analytical columns 4.6 mm internal diameter
-
Unit:
1 Each
-
Length:
50 mm

Compare
OligoPore, 4.6 x 250 mm, 6 µm. Multipore GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 3.3 kDa
-
Unit:
1 Each
-
Length:
250 mm

Compare
OligoPore, 2.1 x 250 mm, GPC column. Multipore GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 3.3 kDa
-
Unit:
1 Each
-
Length:
250 mm

Obsolete. No replacement recommendation. OligoPore Columns Repair gel
-
Unit:
1 Each
OligoPore columns have been developed from an innovative new medium that exhibits significantly increased pore volumes compared to conventional low pore size GPC columns, resulting in higher resolution in the oligomeric region.
Highest resolution gel permeation chromatography (GPC) within a narrow mol weight range.
Application note for silane oligomer analysis with Agilent OligoPore and Gel Permeation Chromatography
- Publication Part Number: 5990-8605EN
- Created: 01 Aug 2011
- 45 KB
| Publication Part Number | 5990-8605EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Contains the conditions for the analysis and fingerprint oligomeric distributions for low molecular weights.
- Publication Part Number: SI-1733
- Created: 20 Oct 2010
- 512 KB
Contains the conditions for the analysis of oligomeric samples and the fingerprinting of oligomeric distributions in organic solvents.
- Publication Part Number: SI-1732
- Created: 20 Oct 2010
- 527 KB
Contains the conditions for OligoPore columns that are designed specifically for the analysis of low molecular weight oligomers in organic solvents.
- Publication Part Number: SI-1731
- Created: 20 Oct 2010
- 520 KB
OligoPore resolves oligomers of oligopin and vitaflavan better than individual pore size columns
- Publication Part Number: 5991-0487EN
- Created: 30 Apr 2015
- 203 KB
| Publication Part Number | 5991-0487EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Demonstrates the combination of the OligoPore columns and the PL-GPC 220 a series of hydrocarbon standards were done in trichlorobenzene at 145 ºC.
- Publication Part Number: SI-01734
- Created: 09 June 2011
- 580 KB
GPC/SEC column user guide for organic, aqueous, and polar/mixed columns. Multi-language insert for the Agilent Bond Elut and Captiva Sample Prep family of products.
- Publication Part Number: 5991-3792EN
- Created: 25 June 2024
- 431 KB
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
| Portuguese (Brazil) | Complete (PDF) |
Agilent robust GPC/SEC columns are used for molecular weight separation using organic solvents.
- Publication Part Number: 5990-7994EN
- Created: 12 June 2017
- 4 MB
| French (France) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Korean (Korea) | Complete (PDF) |
| Italian (Italy) | Complete (PDF) |
| German (Germany) | Complete (PDF) |
| Spanish (Spain) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
| Russian (Russia) | Complete (PDF) |
| Russian (United States) | Complete (PDF) |
Low-molecular-weight resins are made by the addition polymerization of reactive monomers.
- Publication Part Number: 5990-6845EN
- Created: 26 Apr 2012
- 5 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Taiwan - Chinese (Traditional)
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 30 Oct 2025
-
Released: 29 Feb 2024
-
Released: 29 Feb 2024