Inlet liner, split, single taper, glass wool, deactivated, low pressure drop. Offset from the base of the inlet to reduce turbulence and backpressure at the head of the column. Mid-positioned quartz wool promotes even vaporization and traps...
-
Volume:
870 µL
-
Unit:
1 Each

QuickPick PM kit, for split inlet. Includes: 1 split liner (5183-4647), 5 Non-Stick BTO septa (from 5183-4757), 1 Non-Stick O-ring liner (from 5188-5365), 1 Gold Seal and washer kit (5188-5367)
-
Unit:
1 Kit

Agilent Split Liners for GC. Agilent split liners are made to strict dimensional specifications for optimal inlet performance.
- Released: 07 Feb 2024
- 135 KB
-
Released: 07 Feb 2024
-
Released: 07 Feb 2024
Il aborde les points suivants:
- Publication Part Number: 5183-4647
- Created: 01 July 2011
- 5 MB
7697A Liner for Split Injections
7697A Liner for Split Injections
-
Is there a recommendation for the liner that should be used for split injection with the split/splitless inlet? We have been using a 5183-4647, since we sometimes use the instrument for non-headspace assays. I see in the manual that 5181-8818 is used for setup and searching this forum i found that 5190-6168 is the newer version for use with the transfer line interface like we have.
How do I select a Split/Splitless liner?
How do I select a Split/Splitless liner?
-
Split liner A good liner for split mode operation will offer very little restriction to the split flow path between the bottom of the liner and the inlet gold seal and between the outside of the liner and the inside of the injection port body. The preferred Agilent split liner, part number 5183-4647, incorporates a glass positioning bead on the bottom to facilitate this. It will also incorporate glass wool or some other source of surface area inside the liner that provides for complete sample vaporization across the boiling point range of the sample.
GC Liner replacement method
GC Liner replacement method
-
I'd just like to know what are your "standby" method when leaving GC for the night, and also what are your best practise when replacing the liner (part # 5183-4647 split/splitless) Thanks in advance Francois.
Repeatabliity problems on HP7890B
Repeatabliity problems on HP7890B
-
Method information Autosampler Turret - G4513A Syringe - Agilent Gold Tapered (5181 Septa 5183-4757 Bleed/Temp optimised, non stick liner - 5183-4647 (deactivated glass wool, single tapered 4mm) Volume 1ul Solvent pre washes, sample washes, sample postwash all x4 FID Temp - 250oC Pressure 6.5PSI Total flow 36.3ml/min Split flow ratio 2:1 Split flow rate 22.2 ml/min Detector Temp - 250oC Air Flow - 350ml/min H2 flow - 35ml/min Makeup N2 flow - 12ml/min Oven Column -DB-VRX(30mx450umx2.55u)(124-1534) Column flow - 11.1ml/min Pressure - 6.5PSI Velocity - 100.6ml/min Initial oven temp - 38oC Constant type - Pressure Runtime - 17.3 mins Post run temp - 50oC Oven programme 38oC for 9 minutes ramp 40oC/min to 90oC hold time 0 minutes ramp 15oC/min to 180 and hold for 1 minute Things we have tried Maintenance - regularly changing Syringe, liner,septa, o-ring Checked the Autosampler turrets and run on front and back FID - same results Run the same standards on another GC in the lab a HP6890 with same method and HP6890 RSD all ok, HP7890 still problem.
QuickPick PM kit, for split inlet and vent. Includes: 1 split liner (5183-4647), 5 Non-Stick BTO septa (from 5183-4757), 1 Non-Stick O-ring liner (from 5188-5365), 1 Gold Seal and washer kit (5188-5367), 1 split vent cartridge, 2 O-rings (5188-6495)
-
Unit:
1 Kit

Inlet liner, split, single taper, glass wool, deactivated, low pressure drop, 5/pk. Offset from the base of the inlet to reduce turbulence and backpressure at the head of the column. Mid-positioned quartz wool promotes even vaporization and traps...
-
Volume:
870 µL
-
Unit:
5 Pack

Corrected page 158 of The Essential Chromatography Catalog from Agilent, 5989-1212ENUS
- Created: 23 Feb 2005
- 93 KB
This quick reference guide lists the commonly ordered parts and supplies for the Agilent 7890B GC. we have produced this list of the most commonly ordered supplies and parts for the 7890B GC. Keep this list handy so you can quickly find the...
- Publication Part Number: 5990-8916EN-GC
- Created: 02 Jan 2021
- 604 KB
Chromatographic performance on narrow bore columns for Intuvo
- Publication Part Number: 5994-1308EN
- Created: 23 Aug 2019
- 468 KB
| German (Germany) | Complete (PDF) |
|---|---|
| Russian (Russia) | Complete (PDF) |
| Korean (Korea) | Complete (PDF) |
| Portuguese (Brazil) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
| French (France) | Complete (PDF) |
| Italian (Italy) | Complete (PDF) |
| Spanish (Spain) | Complete (PDF) |
| Japanese (Japan) | Complete (PDF) |
Application note for the analysis of fatty acids in Infant Formulas Using a J&W HP-88 Capillary GC Column
- Publication Part Number: 5990-8429EN
- Created: 17 June 2011
- 426 KB
| Publication Part Number | 5990-8429EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|
This application note demonstrates the rapid quantification of total aromatics in gasoline by ASTM D5769 using an 8850 GC with a 5977C GC/MSD and hydrogen carrier gas.
- Publication Part Number: 5994-8386EN
- Created: 28 May 2025
- 810 KB
Purity analysis of N-Methyl Pyrrolidone
- Publication Part Number: 5994-8126EN
- Created: 07 Apr 2025
- 499 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
| Japanese (Japan) | Complete (PDF) |
This application note highlights the analysis of Oil and Fat in foods using the 7890 GC and a 5977 MSD System
- Publication Part Number: 5991-9107EN
- Created: 13 Mar 2018
- 527 KB
Application note for measuring Hydrocarbon Oil Index
- Publication Part Number: 5988-0621EN
- Created: 07 Jan 2014
- 101 KB
Application note for High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System
- Publication Part Number: 5990-9104EN
- Created: 23 Sep 2011
- 312 KB
| Publication Part Number | 5990-9104EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|
Ethanol is a key additive in gasoline, serving as both a smog reducer as well as a supplement...
- Publication Part Number: 5990-6650EN
- Created: 20 Oct 2010
- 224 KB
| Publication Part Number | 5990-6650EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for the trace level analysis of Epichlorohydrin in Drinking Water by Gas Chromatography/Flame Ionization Detector
- Publication Part Number: 5990-6433EN
- Created: 15 Sep 2010
- 277 KB
| Publication Part Number | 5990-6433EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for High Throughput Mineral Oil Analysis by GC-FID Using the Agilent Low Thermal Mass (LTM) System
- Publication Part Number: 5990-4851EN
- Created: 23 Oct 2009
- 315 KB
Application note for automated preparation of simulated distillation samples
- Publication Part Number: 5990-3778EN
- Created: 31 Mar 2009
- 471 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|