The Bravo NGS with on-deck thermal cycler increases walkaway time and ease of use, and streamlines protocols.
Cool on-column inlets afford high precision injection to eliminate sample discrimination, sample alteration.
Repair confidently without contract commitment using Agilent CrossLab On Demand Services. Our certified professionals deliver fast repairs done right the first time. With flexible support using genuine Agilent parts, your instruments are restored...
Minimize sample degradation or discrimination.
Optimized for hybridization of genetic samples for reliable and consistent results
Tune check on positive mode is failing but passing on negative mode
Tune check on positive mode is failing but passing on negative mode
-
Hello, For LCMS 6120 Agilent, I was doing positive mode tuning and it passed, for checking the tune it was good for a few minutes and suddenly signal dropped from around 80000 to 7, checked the calibration valve, flushed system, cleaned ion source and capillary, still signal is very low. However, it is perfectly passing the negative mode. Is it a hardware issue? any help is highly appreciated.
Cd >LOQ on ICS-A for EPA 6020A testing on 7900 ICP-MS
Cd >LOQ on ICS-A for EPA 6020A testing on 7900 ICP-MS
-
For the past week we have had Cd flag on our ICS-A test where the blank ran before and after it show nothing. We've been running this same method for about 3 years now and I've never seen an ICS-A fail so I'm not exactly sure how to go about troubleshooting that.
R^2 only on Calibration report no R= on report
R^2 only on Calibration report no R= on report
-
Currently on the report there is the R^2 and the R. I would like to have just the R^2. Is there a way to remove it either in the report or in the MassHunter 12.2 Quantitative analysis.
custom sample report designer: Is it possible to get all the data on one pdf rather than it generating a separate pdf for each sample
custom sample report designer: Is it possible to get all the data on one pdf rather than it generating a separate pdf for each sample
-
I am trying to create a report template on custom sample report designer. Is it possible to get all the data on one pdf rather than it generating a separate pdf for each sample. I am specifically creating a template for LC-ICP-MS so each page would contain the sample data and chromatogram, but Id like the whole data set in one pdf. Thank you
The HydroInert source is designed to improve chromatographic efficiencies with hydrogen carrier gas.
Target Retrieval Solution, pH 9 (50x) for use with SK032 on Autostainer Link 48
tissue sections prior to immunohistochemical staining on Autostainer Link 48. Tris/EDTA buffer, pH 9. Provided as 3 x 30 mL reagent, 50x concentrated, corresponding to 200–430 tests. The volume is optimized for dilution in PT Link tanks.