Refine Results
- Products
-
- Services
- Content Type
-
Content Type
- Analysis Platform
-
Analysis Platform
- Language
-
Language
Cables up to 100 m long to connect controllers with turbo pumps
Extension cables for turbo pumping systems
A comprehensive range of kits for maintaining and upgrading HPLC pumps
All supplies for pump valves, including inlet valves, outlet valves, and purge valves
A full range of supplies for pump valves, including inlet valves, outlet valves, and check valves
I am trying to set up the AVS pump, but when I add the AVS pump in sample introduction, the avs pump icon should appear on the dashboard. It doesn't do that. How do I configure the ACS pump?
I am trying to set up the AVS pump, but when I add the AVS pump in sample introduction, the avs pump icon should appear on the dashboard. It doesn't do that. How do I configure the ACS pump?
-
But in instructions, it is described that on the dashboard, an icon for the pump should show up, where I can put in the length of the loop, etc. to configure the system. It doesn't do that. So far, I have just been recording the time and entering everything manually.
Agilent G1361 Prep Pump Loud Sound in Pump Drive
Agilent G1361 Prep Pump Loud Sound in Pump Drive
-
Hi all, I have a G1361 Prep pump. All the LA tests are passed and the instruments flow rate matches the set flow rate. The EMPV is also working fine. The only issue is that there is a loud sound when the pump is running which I narrowed down to being in the pump drive. It sounds squeaky and is periodic as the pump drive turns. I was wondering if there any sort of lubricant that can be applied? Or is there any other fix that can be done. Overall the instrument works great minus the loud sound from te pump drive.
5977B with Diffusion Pump randomly throws Fault "HIVAC pump off" in sequence
5977B with Diffusion Pump randomly throws Fault "HIVAC pump off" in sequence
-
We have a similar problem. Msd 5977b gc 7890b. But instead of a turbo pump, we have a diffusion pump. The symptoms are the same: the device works, but stops during a series at a random moment. Were you able to solve this problem? I think the problem is not In the pump.
Agilent LC Binary Pump
Agilent LC Binary Pump
-
Hi there, Recently, I was troubleshooting an Agilent 1100 binary pump where one of the pump heads was delivering a lower flow rate. I swapped the components with those from a properly functioning pump and identified the active inlet valve as the likely source of the problem.
Pump supplies for selected Thermo Fisher Scientific LC systems
Pump supplies for selected Shimadzu HPLC systems, containing the most important pump components
Supplies for maintaining selected Waters HPLC systems, including common pump replacement parts
Original replacement parts for a full range of ion pumps
OEM parts for your Agilent or Varian diffusion pumps
Peristaltic pump tubing for the VGA 77 vapor generation accessory to the hydride module
Convert to the TwisTorr pump family
IDP and TriScroll pumps & modules
Apply upgrade kits to optimize the performance of your HPLC pump and improve reliability of results.
Flexible scroll pump repair options
Covers all TwisTorr and Turbo-V series pumps
Trade-in your old ion pump controller for the newest technology
Vacuum pump supplies designed to ensure the accuracy and performance of Agilent's LC/MS systems.
Get smarter scroll pumps with longer tip seal life
Kits available for online purchase only. Include pump, controller & accessories