A variety of supplies for a range of fraction collectors to suit your purification needs
This product has been prepared from sera of non-immunized rabbits. The immunoglobulin fraction has been isolated in the same way as the immunoglobulin fration of Dako rabbit antibodies.
This product has been prepared from sera of non-immunized rabbits. The immunoglobulin fraction has been isolated in the same way as the immunoglobulin fraction of Dako rabbit antibodies. The protein concentration of X0903 is 20 g/L.
High-purity and high-capacity fraction collection at flows up to 200 mL/min.
High-purity collection of semipreparative quantities at flows between 4 and 100 mL/min.
Inconsistent fraction volumes with fraction collector G1364F?
Inconsistent fraction volumes with fraction collector G1364F?
-
Hello, I'm using a 1200 HPLC with fraction collector G1364F to do some analytical prep work and I've noticed that, despite my collection parameters being time-based (60 sec fractions, flow rate 1 mL/min), the fractions don't all come out at the same volume (= 1 mL). I'd like to flush, or even backflush, the fraction collector, but I can't do so if my needle is not parked in the waste port. Is there a way to park the needle in the "Rinse" position?
Instant pilot does not recognize fraction collector. Firmware issue?
Instant pilot does not recognize fraction collector. Firmware issue?
-
Hello Agilent community, I'm setting up a 1260 Infinity II fraction collector to be paired with G4208A Instant Pilot. After updating the firmware, the controller still does not recognize the FC. Any suggestions are appreciated.
G1363C Fraction collector / Transport initialization failed & no tray detected
G1363C Fraction collector / Transport initialization failed & no tray detected
-
I am having troubles with my G1364C not initializing. Based upon other discussions I likely need to replace the transport unit. However, the module at the same time also reports "no tray installed". I´m just wondering if the tray detection only works after a succesfull initialization or if this is independent. Is it possible to just replace the suspicious motor with part# G1367-89700 (and does it already the encoder mounted)? Thanks in advance...
Instrument Exchange Installation and Deinstallation Instructions for Exchanging Your Fraction Collector
Instrument Exchange Installation and Deinstallation Instructions for Exchanging Your Fraction Collector
-
Instrument Exchange Installation and Deinstallation Instructions for Exchanging Your Fraction Collector
Flexible collection from bioseparations in vials, vessels, or microplates at up to 10 mL/min.
High-volume fraction collection for purification workflows up to 200 mL/min.
High-purity collection of analytical quantities at flows between 0.1 and 10 mL/min.