A biocompatible, quaternary LC system with a pressure range up to 800 bar and flow rates up to 5 mL/min
High-volume fraction collection for purification workflows up to 200 mL/min.
Injection from vials and micoplates of up to 6,144 samples at up to 800 bar.
Easy and reliable injection of up to 20 mL of sample for routine compound purification.
Compare
Characterizes proteins and biomolecules accurately and reproducibly with light scattering detection.
1260 Infinity II HPLC - Error upon lamp ignition/warm up - Cut Filter doesn't decrease light intensity at 250nm
1260 Infinity II HPLC - Error upon lamp ignition/warm up - Cut Filter doesn't decrease light intensity at 250nm
-
Upon lamp ignition/warm up on 1260 Infinity II HPLC I am getting an error that says "Cut Filter doesn't decrease light intensity at 250nm [EE 7813, 0]" I tried replacing the Deuterium Lamp and this was not the problem.
Agilent 1260 Infinity II Openlab CDS connectivity issue.
Agilent 1260 Infinity II Openlab CDS connectivity issue.
-
Openlab CDS was working fine. During sequence, Autosampler used to sample after 1 mint on its own. Sequence aborted. restarted and found another issue. Content Management not in access. error was LOCALHOST:80 freed up space in C and restarted again. same issue detected. after 1 injection in sequence, system shows idle, staus shows acquiring and sampler goes in rest. i am unable to share pics because i have screenshots in my phone internal storage. i can not drag pics now on state HPLC turned on, started openlab cds control pannel. instrument shows not connected untill i start launch . some of services stoped automatically some running automatically problem exists in sequence on 2nd run again. system status becomes idle while activity status on acquiring
1260 Infinity III Pump - Use without degasser?
1260 Infinity III Pump - Use without degasser?
-
Hello, I have a 1260 Infinty III pump. It does not have a degasser but I do not need it at the moment. However, on LabAdvisor, even if I turn off the degasser it still shows an error about how the degasser isnt reaching the correct value or that its not connected.Is there any to to use the pump for some diagnsotics without having the degasser?
1260 Infinity prep HPLC; always ~300 uL left in 5 mL sample vials
1260 Infinity prep HPLC; always ~300 uL left in 5 mL sample vials
-
Hi all We have the following modules and loop installed on our prep. HPLC and even with the needle offset at the minimum (-2.5 mm), the autosampler always leaves about 300 uL of sample in the vial. What can I do to try and minimise the volume remaining in the vial? For experiments I filled a 5 mL vial with 800 uL of water, ask it to inject 800 uL with a -2.5 mm needle offset and there was ~300 uL remaining. Thanks to anyone for any advise at all, and please let me know if you need further info on the setup. Autosampler: Analytical head: 900 uL G7129-600883 Seat capillary: Multidraw Seat Capillary: 4500 uL (G7157-6811+G1313-87308) Loop capillary: loop for Prep Autosampler (G7157-60515) Mark
Direct injections and retain-sample functionality for fast, confident process monitoring.
MALS Detector for determination of absolute molecular weight in GPC/SEC.
High-sensitivity, single-wavelength UV detection from 190 to 600 nm at 120 Hz and ±2.5 µAU/cm noise.
Compare
Reliable analysis of biological polymers with metal-free flow path and optional advanced detectors
Compare
Fast, automated, and robust process monitoring via LC applications.
Compare
HPLC/UHPLC quaternary solvent mixing with pressure range up to 800 bar and flow rates up to 5 mL/min.
Quaternary solvent delivery for biological and extreme pH applications up to 600 bar.
Binary solvent delivery at pressures up to 600 bar and flow rates up to 5 mL/min.
600 bar and 5 mL/min power range for extended SFC and SFC/MS application reach.
Compare
Automated amino acid analysis with latest HPLC technology and proven precolumn derivatization.
High-sensitivity, multisignal data and spectra in a single run at up to 148 Hz.
High capacity with LC-like injection precision and reproducibility for SFC and SFC/MS applications.
Wide-range, UV-spectral detection from 190 to 950 nm with 120 Hz sampling.
High capacity up to 6,144 samples and 600 bar, and metal-free flow path for bio-applications.
Compare
Bio-inert analytical HPLC purification system with corrosion-resistant flow path to protect biomolecules