Refine Results
- Products
-
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Chemical Group
- Compounds
-
Compounds
- Instrument
- Method
- Packaging
-
Packaging
- Solvent
-
Solvent
- Analyte
-
Analyte
- CAS Number
-
CAS Number
- Concentration
-
Concentration
- Format
-
Format
- Technique
-
Technique
- Unit Quantity
-
Unit Quantity
- Volume
-
Volume
- Analysis Platform
-
Analysis Platform
- Language
-
Language
Need help finding the right ICP supplies? Try our ICP Supplies Selector Tool.
5190-8596, 200.8 Tuning & Resolution Solution: 10 µg/mL Be, Mg, Co, In, Pb in 5% HNO3, LOT:0009745012, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 22 June 2018
- 241 KB
5190-8596, 200.8 Tuning & Resolution Solution: 10 µg/mL Be, Mg, Co, In, Pb in 5% HNO3, LOT: 0009745013, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 22 June 2018
- 238 KB
Online MSA calibration using prepFAST S automated sample introduction and Agilent 8900 ICP-QQQ
- Publication Part Number: 5991-9487EN
- Created: 06 June 2018
- 548 KB
5190-8597, 6020 Tuning & Resolution Solution: 10 µg/mL Li, Co, In, Tl in 5% HNO3, LOT: 0007521982, Certificate of Analysis
- Publication Part Number: 5190-8597
- Created: 17 Apr 2018
- 236 KB
50 elements in HCl were analysed using MS/MS mode to resolve the polyatomic interferences. All analytes could be determined directly in the undiluted HCl with single digit ppt detection limits.
- Publication Part Number: 5991-8675EN
- Created: 09 Nov 2017
- 1 MB
Detection limits in the single digit ppt or sub-ppt range were obtained for 48 elements, demonstrating the ability of the 7700s/7900 to routinely measure trace contaminants.
- Publication Part Number: 5990-7914EN
- Created: 02 Oct 2017
- 533 KB
| Publication Part Number | 5990-7914EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
A new method for the rapid analysis of Radium-266 in water that is dramatically quicker than decay counting and meets regulatory detection limits.
- Publication Part Number: 5991-8324EN
- Created: 08 Aug 2017
- 382 KB
The elements in 65 red wines were studied using ICP-MS to determine if the elemental profile could be used to determine the geographical origin of the wines.
- Publication Part Number: 5991-6111EN
- Created: 04 July 2017
- 134 KB
Increasing the throughput of water samples using EPA method 200.8 on an Agilent 7900 ICP-MS with a fully automated prepFAST M5 autodilution system
- Publication Part Number: 5991-8148EN
- Created: 04 July 2017
- 1 MB
5190-8596, 200.8 Tuning & Resolution Solution: 10 μg/mL Be, Mg, Co, In, Pb in 5% HNO3, Lot 0001361582, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 28 Mar 2017
- 281 KB
5190-8596, 200.8 Tuning & Resolution Solution: 10 μg/mL Be, Mg, Co, In, Pb in 5% HNO3, Lot 0001361584, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 28 Mar 2017
- 281 KB
5190-8596, 200.8 Tuning & Resolution Solution: 10 μg/mL Be, Mg, Co, In, Pb in 5% HNO3, Lot 0001361586, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 28 Mar 2017
- 281 KB
5190-8596, 200.8 Tuning & Resolution Solution: 10 μg/mL Be, Mg, Co, In, Pb in 5% HNO3, Lot: 0001361587, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 28 Mar 2017
- 188 KB
5190-8596, 200.8 Tuning & Resolution Solution: 10 μg/mL Be, Mg, Co, In, Pb in 5% HNO3, Lot 0001361585, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 28 Mar 2017
- 281 KB
5190-8596, 200.8 Tuning & Resolution Solution: 10 μg/mL Be, Mg, Co, In, Pb in 5% HNO3, Lot 0001361583, Certificate of Analysis
- Publication Part Number: 5190-8596
- Created: 28 Mar 2017
- 281 KB
5184-3566, Tuning Solution, 23-167GSX2, Certificate of Analysis
- Created: 15 Mar 2017
- 396 KB
5188-6524, 7500 Serles PA Tuning 2, 3-75MKBY2, Certificate of Analysis
- Created: 15 Feb 2017
- 239 KB
5184-3566, Tuning Solution, 23-18GSX2, Certificate of Analysis
- Created: 31 Dec 2016
- 230 KB
5184-3566, Tuning Solution, 22-223GSX2, Certificate of Analysis
- Created: 15 Nov 2016
- 236 KB
Using the high sensitivity Agilent 8900 Triple Quadrupole ICP MS (ICP-QQQ) to analyse low level S IR of mineral waters
- Publication Part Number: 5991-7285EN
- Created: 14 Sep 2016
- 800 KB