Captiva EMR-Lipid HF 6 mL 600 mg 50/pk. Designed for high flow (HF) rates using gravity, this enhanced matrix removal (EMR) product significantly reduces sample processing time for complex samples, such as meat and fish. This product is recommended...
-
Unit:
50 Pack

Agilent Captiva EMR-Lipid, 1 mL, 96-well plate, 40 mg sorbent mass, with solvent retention frit, 5/pk. Highly selective, efficient lipid/matrix removal without analyte loss.
-
Volume:
1 mL
-
Unit:
5 Pack

Compare
Bond Elut EMR-Lipid Polish 15 mL Tube containing 2 g anhydrous MgSO4/NaCl (4:1), 50/pk. Acceptable for use in QuEChERSER sample preparation. To phase separate the ACN/water, and remove dissolved solids. Acceptable for use in QuEChERSER extractions.
-
Unit:
50 Pack

Compare
Bond Elut EMR-Lipid Polish Pouch, anhydrous MgSO4 only, 50/pk. Removes excess water and improves analyte partitioning.
-
Unit:
50 Pack

Compare
Bond Elut EMR-Lipid dispersive SPE, 50/PK. Contains 1 g of preweighed sorbent in 15 mL centrifuge tubes. Easily accommodate the aliquot volumes specified by current AOAC and EN methodologies.
-
Unit:
50 Pack

Agilent Captiva EMR PFAS Food II passthrough cleanup and LC/MS/MS detection.
- Publication Part Number: 5994-8610EN
- Created: 01 May 2026
- 631 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
| Japanese (Japan) | Complete (PDF) |
This application note presents the development and validation of a multiresidue method for the analysis of 43 PFAS in beers and wines, using Captiva EMR PFAS Food I passthrough cleanup and LC/MS/MS detection.
- Publication Part Number: 5994-8813EN
- Created: 24 Nov 2025
- 1 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application note demonstrates a simple, reliable method for quantitation of 40 PFAS in soil using QuEChERES-EMR method followed with 6495D LC/TQ.
- Publication Part Number: 5994-8778EN
- Created: 13 Nov 2025
- 364 KB
This application note describes the development and validation of a multiresidue method for analyzing 40 per- and polyfluoroalkyl substances (PFAS) in biosolids.
- Publication Part Number: 5994-8777EN
- Created: 13 Nov 2025
- 458 KB
This application note presents the development and validation of a multiresidue method for the analysis of per and polyfluoroalkyl substances (PFAS) residues in tilapia.
- Publication Part Number: 5994-8232EN
- Created: 16 June 2025
- 794 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application brief presents a newly developed and validated multiresidue method for analysis of PFAS in bovine kidney.
- Publication Part Number: 5994-7370EN
- Created: 14 Apr 2025
- 454 KB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
This application note presents a newly developed and validated multiresidue method for analysis of PFAS in infant formula, milk, and eggs.
- Publication Part Number: 5994-7366EN
- Created: 14 Apr 2025
- 1 MB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
This application note presents the development and validation of a multiresidue method for the analysis of per- and polyfluoroalkyl substances (PFAS) in baby food.
- Publication Part Number: 5994-7367EN
- Created: 14 Apr 2025
- 651 KB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
| Japanese (Japan) | Complete (PDF) |
This application brief presents a newly developed and validated multiresidue method for analysis of PFAS in soy bean.
- Publication Part Number: 5994-7371EN
- Created: 14 Apr 2025
- 555 KB
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
This application note presents the development and validation of a multiresidue method for the analysis of per- and polyfluoroalkyl substances (PFAS) residues in beef, tuna, and shrimp.
- Publication Part Number: 5994-7368EN
- Created: 14 Apr 2025
- 1 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
| Japanese (Japan) | Complete (PDF) |
This application brief presents a newly developed and validated multiresidue method for analysis of PFAS in fruits, vegetables and juice.
- Publication Part Number: 5994-7369EN
- Created: 14 Apr 2025
- 2 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Korean (Korea) | Complete (PDF) |
Using Captiva EMR-Lipid HF With the 6495C LC/TQ to Analyze 193 Veterinary Drug Residues in Livestock and Poultry Meat
- Publication Part Number: 5994-8233EN
- Created: 20 Mar 2025
- 1 MB
This application note presents a study for the method limit of quantitation (LOQ) determination for 30 per- and polyfluoroalkyl substances (PFAS) targets in foods using a newly developed method.
- Publication Part Number: 5994-8028EN
- Created: 08 Jan 2025
- 342 KB
General instructions for Agilent Captiva EMR PFAS Food I and II cartridges
- Publication Part Number: 5994-7302EN
- Created: 01 June 2024
- 521 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application note presents the development and validation of a multiresidue method for the analysis of 21 mycotoxins in dry corn kernel and soybean samples.
- Publication Part Number: 5994-7373EN
- Created: 01 June 2024
- 692 KB