Refine Results
- Products
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Chemical Group
-
- Compounds
-
Compounds
- Instrument
-
- Analysis Platform
-
Analysis Platform
- Spectroscopy Instrument Compatibility
-
Spectroscopy Instrument Compatibility
- Language
-
Language
Application note for Analysis of major elements in fruit juices using the Agilent 4200 MP-AES with the Agilent 4107 Nitrogen Generator
- Publication Part Number: 5991-3613EN
- Created: 06 Jan 2014
- 610 KB
| Publication Part Number | 5991-3613EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for Analysis of major, minor and trace elements in rice flour using the 4200 MP-AES
- Publication Part Number: 5991-3777EN
- Created: 05 Jan 2014
- 631 KB
| Publication Part Number | 5991-3777EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Application note for Determination of major and minor elements in geological samples using the 4200 MP-AES
- Publication Part Number: 5991-3772EN
- Created: 05 Jan 2014
- 2 MB
| Publication Part Number | 5991-3772EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
6610030700, Calibration Mix Majors, 125 mL, Lot 0031200802, Certificate of Analysis
- Publication Part Number: 6610030700
- Created: 03 Jan 2014
- 644 KB
6610030700, Calibration Mix Majors, 125 mL, Lot 0031200801, Certificate of Analysis
- Publication Part Number: 6610030700
- Created: 03 Jan 2014
- 644 KB
6610030700, Calibration Mix Majors, 125 mL, Lot 0031200803, Certificate of Analysis
- Publication Part Number: 6610030700
- Created: 03 Jan 2014
- 968 KB
6610030100, Wavelength Calibration Solution for ICP-OES & MP-AES, 5 mg/L, 500 mL, Certificate of Analysis
- Publication Part Number: 6610030100
- Created: 17 Dec 2013
- 648 KB
6610030100, Wavelength Calibration Solution for ICP-OES & MP-AES, 5 mg/L, 500 mL, Lot 0031200471, Certificate of Analysis
- Publication Part Number: 6610030100
- Created: 17 Dec 2013
- 558 KB
610030100, Wavelength Calibration Solution for ICP-OES MP-AES, 5 mg/L, 500 mL, Lot 0031100753, Certificate of Analysis
- Publication Part Number: 6610030100
- Created: 19 Nov 2013
- 557 KB
6610030100, Wavelength Calibration Solution for ICP-MS & MP-AES, 5 mg/L, 500 mL, Lot 0031100752, Certificate of Analysis
- Publication Part Number: 6610030100
- Created: 19 Nov 2013
- 781 KB
6610030500, Calibration Mix 1, 125 mL, Lot 0030900561, Certificate of Analysis
- Publication Part Number: 6610030500
- Created: 05 Oct 2013
- 1 MB
5190-8402, Iron Standard: 10000 μg/mL Fe in 5% HNO3, Lot 0000821420, Certificate of Analysis
- Publication Part Number: 5190-8402
- Created: 30 Aug 2013
- 215 KB
6610030700, Calibration Mix Majors, 125 mL, Lot 0030500333, Certificate of Analysis
- Publication Part Number: 6610030700
- Created: 23 May 2013
- 642 KB
6610030700, Calibration Mix Majors, 125mL, Lot 0003050033, Certificate of Analysis
- Publication Part Number: 6610030700
- Created: 23 May 2013
- 774 KB
6610030700, Calibration Mix Majors, 125 mL, Lot 0030500332, Certificate of Analysis
- Publication Part Number: 6610030700
- Created: 23 May 2013
- 787 KB
6610030700, Calibration Mix Majors, 125mL, Lot 0002040058, Certificate of Analysis
- Publication Part Number: 6610030700
- Created: 18 Mar 2013
- 774 KB
The pressure to stay productive, profitable, and compliant is more intense than ever.
- Publication Part Number: 5990-9649EN
- Created: 07 Dec 2012
- 14 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This application note describes a new method for the measurement of additives in lubricating oils.
- Publication Part Number: 5990-8925EN
- Created: 11 Oct 2012
- 785 KB
| Publication Part Number | 5990-8925EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Application note explaining a technique for determining the concentration of base metals in mining ores.
- Publication Part Number: 5990-9014EN
- Created: 26 Sep 2012
- 122 KB
| Publication Part Number | 5990-9014EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
5190-8331, Cerium Standard: 1000 µg/mL Ce in 5% HNO3, LOT: 0015261946, Certificate of Analysis
- Publication Part Number: 5190-8331
- Created: 22 Sep 2010
- 244 KB