Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
- Instrument
-
- Method
-
- Analysis Platform
-
Analysis Platform
- Language
-
Language
An automated precolumn OPA/FMOC amino acid method for 3.5 and 1.8 µm ZORBAX Eclipse Plus C18 transfers to 2.7 µm Poroshell HPH-C18 with good lifetime and results
- Publication Part Number: 5991-5571EN
- Created: 07 July 2015
- 2 MB
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Portuguese (Brazil) | Complete (PDF) |
solutions to win
- Publication Part Number: 5991-5316EN
- Created: 12 June 2015
- 1 MB
Application note for the analysis of foods using HPLC with evaporative light scattering detection
- Publication Part Number: 5990-9456EN
- Created: 01 June 2015
- 281 KB
Application note for polyether ether ketones on Agilent PLgel MIXED-B with Gel permeation Chromatography
- Publication Part Number: 5990-8422EN
- Created: 30 Apr 2015
- 159 KB
| Publication Part Number | 5990-8422EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Application note for SEC Analysis of Chitosan
- Publication Part Number: 5991-5786EN
- Created: 30 Apr 2015
- 660 KB
Gel permeation chromatography (GPC or SEC) is ideally suited to analyze biodegradable polymers by giving an insight into the rate at which a material might degrade.
- Publication Part Number: 5990-6920EN
- Created: 19 Aug 2014
- 510 KB
Application note for the separation of enantiomers and conformers of Tofisopamon
- Publication Part Number: 5990-9315EN
- Created: 13 Feb 2014
- 2 MB
Application note for the automated nitrate analysis of water
- Publication Part Number: SI-A-1116
- Created: 04 Feb 2014
- 143 KB
Application note for fast analysis of Carbohydrates in Chocolate using Ligand Exchange Chromatography with ELSD
- Publication Part Number: SI-01097
- Created: 29 Jan 2014
- 167 KB
| Publication Part Number | SI-01097 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
In this compendium, you’ll find a compilation of Application Notes from past Agilent Information Pipeline eNewsetters, for the Energy and Chemical industry.
- Publication Part Number: Compendium
- Created: 04 Dec 2013
- 22 MB
Application note for Determination of metals in soil by microwave plasma - atomic emission spectrometry (MP-AES) using DTPA extraction
- Publication Part Number: 5991-2961EN
- Created: 19 Aug 2013
- 2 MB
The dissolution and assay analyses of norethindrone and mestranol are improved by using superficially porous Agilent Poroshell 120 columns
- Publication Part Number: 5991-1688EN
- Created: 07 Jan 2013
- 112 KB
| Publication Part Number | 5991-1688EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The dissolution and assay analyses of diphenhydramine and pseudoephedrine are improved by using superficially porous Agilent Poroshell 120 columns,
- Publication Part Number: 5991-1687EN
- Created: 07 Jan 2013
- 108 KB
| Publication Part Number | 5991-1687EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Environmental Compendium - Soil
- Publication Part Number: compendium
- Created: 12 Oct 2012
- 16 MB
In this study an automatic flame atomic absorption system was used for sequential analysis.
- Publication Part Number: SI-A-1091
- Created: 28 Sep 2012
- 347 KB
Separations of sugars using HPLC with Hi-Plex columns and water eluents are easily achieved, avoiding the need for toxic acetonitrile.
- Publication Part Number: SI-01407
- Created: 28 Sep 2012
- 153 KB
| Publication Part Number | SI-01407 | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|
The separation and detection of raffinose, lactose, glucose, galactose, and fructose are readily achieved using water as the mobile phase with a Hi-Plex Ca column and an ELSD.
- Publication Part Number: SI-01166
- Created: 27 Sep 2012
- 263 KB
| Publication Part Number | SI-01166 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
PD
- Publication Part Number: SI-A-1425
- Created: 25 Sep 2012
- 41 KB
The Agilent 385-ELSD is an advanced evaporative light scattering detector that delivers subambient evaporation...
- Publication Part Number: 5990-9455EN
- Created: 25 Apr 2012
- 270 KB
A compendium of Agilent Hi-Plex ligand-exchange HPLC column application notes providing solutions for lower-pressure analysis of carbohydrates, alcohols, and organic acids.
- Publication Part Number: 5990-8801EN
- Created: 20 Oct 2011
- 7 MB