Refine Results
- Products
-
Product Category
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
-
- Instrument
-
Instrument
- Method
-
- Agency Method
-
Agency Method
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Manufacturer Compatibility
-
Manufacturer Compatibility
- Solvent
-
Solvent
- Analyte
-
Analyte
- CAS Number
-
CAS Number
- Concentration
-
Concentration
- Unit Quantity
-
Unit Quantity
- Analysis Platform
-
Analysis Platform
- Language
-
Language
Recommended for EPA methods 502.2 and 8021, as well as for fast GC/MS analysis of volatiles.
Designed for trace analysis in environmental, pharmaceutical, and other volatile organic compound (VOC) applications.
Designed for residual solvent analysis of pharmaceutical compounds per US Pharmacopeia Method <467>.
DB-624 J&W GC Column, 100 m, 0.53 mm, 3.00 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.
-
Unit:
1 Each
-
Length:
100 m

J&W DB-624 GC Column, 20 m, 0.18 mm, 1.00 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.
-
Unit:
1 Each
-
Length:
20 m

Unknown peak co-eluting with MeOH on DB-624 GC-FID
Unknown peak co-eluting with MeOH on DB-624 GC-FID
-
Hello, I am injecting ethanol samples by direct injection which contain trace amounts of methanol and notice the methanol peak varies injection to injection on the same sample. I also injected pure air (empty vial injection) to find out if there is something eluting from the system and notice there is a peak with the same RT of methanol at the that varies by injection to injection. I am wondering where this unknown peak is coming from, since it is interfering with my ability to quantitate trace levels of methanol. I changed the liner, septum, o-ring, gold seal, column, syringe and the issue reappears.
MTBE addition to method, oven ramp suggestions
MTBE addition to method, oven ramp suggestions
-
Hello, our lab is running GC-HS with a DB-624 column for wastewater analysis. We would like to add methyl tert butyl ether as a compound to our method. However, the MTBE retention time is at the same time as our hexane isomer compounds.
USP Chapter <467> Residual Solvents Update 2025. Coelution cyclopentyl methyl ether vs pyperidine
USP Chapter <467> Residual Solvents Update 2025. Coelution cyclopentyl methyl ether vs pyperidine
-
Reviewing application note 5994-6020EN, I see that, with this column and under conditions, benzene and 1,2-dichloroethane can be separated with a resolution of 1.8, which is part of what we need: Now, I suppose that by purchasing and using the DB-select 624 (UI), which is an improved version of the DB-624, this can also resolve the piperidine vs. cyclopentyl methyl ether problem without any issues. Is that correct? My specific question is: Would the DB-Select 624 (UI) allow pyridine/cyclopentyl methyl ether to be resolved without sacrificing the resolution of the benzene/1,2-dichloromethane pair under the same conditions as the USP (Procedure A)?
Problem with Diluent (DMF) peak tailing
Problem with Diluent (DMF) peak tailing
-
Hello Everyone, I am performing Gas chromatography by headspace (using Agilent 7890 and G1888 headspace). My GC parameters are as below Diluent: dimethylformamide Column: DB-624, 30m X 0.53 X 3.0 µ Inlet temp: 140 detector temp: 250 Headspace Incubation temp 105 Loop temp 120 transfer line 130 I am getting problem with Diluent (DMF) peak tailing.
J&W DB-624 GC Column, 20 m, 0.18 mm, 1.00 µm, LTM column module. This format is only compatible with Agilent Low Thermal Mass Series Rapid Heating/Cooling (LTM) Systems.
-
Unit:
1 Each
-
Length:
20 m

J&W DB-624 Ultra Inert GC Column, 20 m, 0.18 mm, 1.00 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly...
-
Unit:
1 Each
-
Length:
20 m

Compare
J&W DB-624 Ultra Inert Intuvo GC column module, 20 m, 0.18 mm, 1.00 µm. (compatible only with the Intuvo 9000 GC System)
-
Unit:
1 Each
-
Length:
20 m

J&W DB-Select 624 Ultra Inert GC Column, 30 m, 0.25 mm, 1.40 μm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a...
-
Unit:
1 Each
-
Length:
30 m

J&W DB-Select 624 Ultra Inert GC Column, 60 m, 0.25 mm, 1.40 μm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a...
-
Unit:
1 Each
-
Length:
60 m

J&W DB-624 GC Column, 30 m, 0.25 mm, 1.40 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.
-
Unit:
1 Each
-
Length:
30 m

J&W DB-624 GC column, 30 m, 0.25 mm, 1.40 µm, with smart key, for 8890 GC system
-
Unit:
1 Each
-
Length:
30 m

J&W DB-624 GC Column, 30 m, 0.25 mm, 1.40 µm, LTM column module. This format is only compatible with Agilent Low Thermal Mass Series Rapid Heating/Cooling (LTM) Systems.
-
Unit:
1 Each
-
Length:
30 m

J&W DB-624 Ultra Inert GC Column, 30 m, 0.25 mm, 1.40 μm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly...
-
Unit:
1 Each
-
Length:
30 m

Compare
J&W DB-624 Ultra Inert Intuvo GC column module, 30 m, 0.25 mm, 1.40 µm. (compatible only with the Intuvo 9000 GC System)
-
Unit:
1 Each
-
Length:
30 m

J&W DB-624 GC Column, 60 m, 0.25 mm, 1.40 µm, 7 inch cage. This is the most common GC column format compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems and all non-Agilent GC systems with a similarly sized oven.
-
Unit:
1 Each
-
Length:
60 m

J&W DB-624 GC column, 60 m, 0.25 mm, 1.40 µm, with smart key, for 8890 GC system
-
Unit:
1 Each
-
Length:
60 m
