VF-624ms
제품 정보
- VF-624ms is designed for analyzing solvents according to EPA Methods 524, 624 and 8260, as well as USP 467
- VF-1301ms ultra-low-bleed thin-film has a similar selectivity to 624 and is suitable for semivolatile organic solvents, as well as PCBs and pesticides
- Enhanced selectivity for USP 467 eliminates co-elution of benzene and 1,2-dichloroethane
- Mid polarity
- Low bleed
- 0.15 mm id columns available for high efficiency GC and GC/MS analyses
- Supplied with an EZ-GRIP to simplify column installation, coupling and operation
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Similar Phases: AT-624, Rxi-624 Sil MS, Rtx-624, PE-624, 007-624, 007-502, ZB-624
Capillary | |
ID (mm) | 0.15 - 0.32 mm |
Length (m) | 15 - 60 m |
Film (µm) | 0.84 - 1.80 µm |
Temperature Limits (°C) | -40 -280/300 °C |
Megabore | |
ID (mm) | 0.53 mm |
Length (m) | 30 - 75 m |
Film (µm) | 3.00 µm |
Temperature Limits (°C) | -40 -280/300 °C (30 m) |
-40 -265/280 °C (60, 75 m) |
- 응용 자료
-
USP 467 Residual Solvents
For USP-467 with Agilent J&W VF-624ms, replacing a 30 m x 0.32 mm column for one of 15 m x 0.15 mm reduces analysis time by more than half.because the efficiency is higher.
- 응용 자료
- English
- 10 Apr 2017
- 1.02 MB
Determination of halogenated hydrocarbons in water
Agilent J&W VF-624ms columns separate 31 halogenated hydrocarbon pollutants in less than 40 minutes.
- 응용 자료
- English
- 30 May 2014
- 1.46 MB
Residual Solvents
Gas chromatography with an Agilent J&W VF-624ms GC column resolves residual solvents in 12 minutes.
- 응용 자료
- English
- 04 Nov 2013
- 759.22 KB
USP-467 residual solvents
Gas chromatography with an Agilent J&W VF-624ms column separates 27 residual solvents in 40 minutes.
- 응용 자료
- English
- 04 Nov 2013
- 806.68 KB
Analysis of Nitrosamines in Drinking Water Using the Agilent 5977A Series GC/MSD System
A method has been developed on the Agilent 5977A Series GC/MSD System that can provide detection of N-nitrosamines in water at sub-part per trillion (ppt) levels
- 응용 자료
- English
- 25 Apr 2013
- 80.93 KB
- 데이터 시트
- 홍보자료
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27