- Ultra-low bleed 14% cyanopropyl/phenyl/86% polydimethylsiloxane phase
- Mid polarity
- Ideal for pesticides, PCBs and semi-volatile organic compounds
- Highly inert for difficult analytes such as p,p’-DDT
- Deactivated for accurate trace analysis
- Engineered for reduced bleed, (bleed specification is 2 pA at 280 °C for a 0.25 mm x 60 m, 0.25 μm id column)
- 0.15 mm id columns available for high efficiency GC and GC/MS analyses Supplied with an EZ-GRIP to simplify column installation, coupling and operation
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Microbore | |
ID (mm) | 0.10 mm |
Length (m) | 10 - 20 m |
Film (µm) | 0.10 - 0.40 µm |
Temperature Limits (°C) | -20 -280/300 °C |
Capillary | |
ID (mm) | 0.15 - 0.32 mm |
Length (m) | 15 - 60 m |
Film (µm) | 0.10 - 1.00 µm |
Temperature Limits (°C) | -20 -280/300 °C |
Megabore | |
ID (mm) | 0.53 mm |
Length (m) | 15 - 60 m |
Film (µm) | 0.10 - 1.50 µm |
Temperature Limits (°C) | -20 -280/300 °C (1.00 µm) |
-20 -265/280 °C (1.50 µm) |
- 응용 자료
-
Nitro compounds
Agilent VF-J&W 1701ms columns separate eight nitro compounds in 22 minutes.
- 응용 자료
- English
- 27 May 2014
- 536.34 KB
Base neutrals
Agilent J&W VF-1701ms columns separate 14 base neutrals in 37 minutes.
- 응용 자료
- English
- 27 May 2014
- 712.35 KB
Aromatic volatiles
An Agilent J&W VF-1701ms column separates 11 aromatic volatiles in ten minutes.
- 응용 자료
- English
- 27 May 2014
- 607.88 KB
Nitro- and chlorinated aromatics
Separation of 14 nitro-and halogenated aromatic compounds (base neutrals) by Agilent J&W VF-1701ms in 20 minutes.
- 응용 자료
- English
- 27 May 2014
- 633.51 KB
Nitrosamines
Separation of nine nitrosamines using Agilent J&W VF-1701ms in 20 minutes.
- 응용 자료
- English
- 27 May 2014
- 758.75 KB
Phenols
Phenols are analyzed by GC according to EPA 8040A using the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms.
- 응용 자료
- English
- 27 May 2014
- 869.43 KB
GC Analysis of Halogenated Pesticides using the Agilent J&W FactorFour VF-1701ms with EZ-Guard
Application note for GC Analysis of Halogenated Pesticides using the Agilent J&W FactorFour VF-1701ms with EZ-Guard
- 응용 자료
- English
- 29 Jan 2014
- 150.09 KB
Aniline purity
The analysis of trace impurities in aniline takes 15 minutes with an Agilent J&W VF-1701ms GC column.
- 응용 자료
- English
- 04 Nov 2013
- 563.57 KB
Trace solvents in ethanol
Separation of trace impurities in ethanol in a pharmaceutical application uses gas chromatography with an Agilent J&W VF-1701ms column.
- 응용 자료
- English
- 04 Nov 2013
- 834.39 KB
Tin compounds in strawberry
GC separation of organometallic (tin) compounds with J&W Agilent VF-1701ms and inert transfer lines, with trace analysis by MS with single ion monitoring/scanning.
- 응용 자료
- English
- 04 Nov 2013
- 1.64 MB
- 인용
- 데이터 시트
- 홍보자료
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27