Select Al2O3 MAPD
Select Al2O3 MAPD
- Capillary
제품 정보
- Aluminum oxide PLOT column for the analysis of reactive hydrocarbons such as methyl acetylene and propadiene (MAPD)
- Optimized to improve sensitivity and response
- Faster run improves operating efficiency
- Two-fold higher response for MAPD, especially important when running impurity analyses
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Similar Phases: Rt-Alumina BOND/MAPD, MXT-Alumina BOND/MAPD
Configuration choices for Agilent J&W Select Al2O3
Capillary | |
id (mm) | 0.32 mm |
Length (m) | 25 - 50 m |
Temperature Limits (°C) | -100 -200/200 °C |
Megabore | |
id (mm) | 0.53 mm |
Length (m) | 50 m |
Temperature Limits (°C) | -100 -200/200 °C |
- 응용 자료
-
Impurities in propylene
Acetylene, methylacetylene, and propadiene impurities, among others, are present in propylene. Specifications are set on these polar hydrocarbons. The Agilent J&W Select Al2O3
- 응용 자료
- English
- 13 Jun 2014
- 633.75 KB
Impurities in 1,3 butadiene
Selectivity of the Agilent J&W Select Al2O3 MAPD column is very good for separating impurities in 1,3 butadiene by GC.
- 응용 자료
- English
- 13 Jun 2014
- 739.78 KB
Impurities in propylene
Agilent J&W Select Al2O3 MAPD is extensively deactivated for a high response to trace polar hydrocarbons, including acetylenes and dienes, in propylene analysis.
- 응용 자료
- English
- 04 Jun 2014
- 701.13 KB
Impurities in propylene
The Agilent J&W Select Al2O3 MAPD 0.53 mm column is highly deactivated, with an excellent response when analyzing trace polar hydrocarbons, including acetylenes and dienes, in
- 응용 자료
- English
- 04 Jun 2014
- 1.11 MB
C1-C5 hydrocarbons
The Agilent J&W Select Al2O3 MAPD is extensively deactivated for a high response for GC trace analysis of 14 polar hydrocarbons, including acetylenes and dienes.
- 응용 자료
- English
- 03 Jun 2014
- 864.18 KB
C1 – C5 hydrocarbons
Selectivity of the Agilent J&W Select Al2O3 MAPD column is very high in the separation of seven impurities in a hydrocarbon stream.
- 응용 자료
- English
- 30 May 2014
- 449.66 KB
C1 – C5 hydrocarbons
GC analysis of seven impurities in a hydrocarbon stream is accomplished in less than 12 minutes using the Agilent J&W Select Al2O3 MAPD column.
- 응용 자료
- English
- 30 May 2014
- 415.36 KB
C1 – C4 hydrocarbons
GC analysis of impurities in hydrocarbons is achieved in 12 minutes using the Agilent J&W Select Al2O3 MAPD column.
- 응용 자료
- English
- 30 May 2014
- 831.56 KB
C1 – C4 hydrocarbons
GC analysis of C1 to C4 hydrocarbons is achieved in 15 minutes using the Agilent J&W Select Al2O3 MAPD.
- 응용 자료
- English
- 30 May 2014
- 989.54 KB
Save time - use our online GC column selection tool to find the right GC column for your application in just a few clicks!
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27