PoraPLOT U
PoraPLOT U
Capillary PLOT PT columns
- Capillary
제품 정보
- The most polar porous polymer PLOT column ideal for halogenated compounds, C1-C6 hydrocarbons, ketones and solvents
- Excellent peak shape of polar and non-polar volatiles
- Water has no effect on retention times and elutes as a sharp quantifiable peak
- Reliable retention time repeatability
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
- Similar phases: Rt-U-BOND
Configuration choices for Agilent J&W PoraPLOT U
Capillary | |
ID (mm) | 0.25 - 0.32 mm |
Length (m) | 10 - 25 m |
Film (µm) | 8.00 - 10.00 µm |
Temperature Limits (°C) | -100 -190/190 °C |
Megabore | |
ID (mm) | 0.53 mm |
Length (m) | 10 - 25 m |
Film (µm) | 20.00 µm |
Temperature Limits (°C) | -100 -190/190 °C |
- 응용 자료
-
Agilent 490 Micro GC 바이오가스 분석기를 이용한 바이오가스 분석
이 응용 자료에서는 Agilent 490 Micro GC 바이오가스 분석기를 이용한 바이오가스 및 관련 시료의 분석에 대해 다룹니다.
- 응용 자료
- Korean
- 29 Mar 2019
- 2.45 MB
- QXP
Agilent 490 Micro GC QUAD를 사용한 빠른 정제 가스 분석
휴대용 Agilent 490 Micro GC QUAD를 사용하면 초고속 정제 가스 분석(RGA)이 가능합니다. 본 자료는 단 2분만에 RGA 결과를 획득할 수 있는 490 Micro GC의 사용법을 소개합니다.
- 응용 자료
- Korean
- 25 Mar 2019
- 664.80 KB
Hydrocarbons C1 – C6
Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- 응용 자료
- English
- 30 Jan 2023
- 382.63 KB
Fast Refinery Gas Analysis Using the 490 GC Micro GC QUAD
Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD. This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- 응용 자료
- English
- 08 Jan 2016
- 952.53 KB
Composition Analysis of Contaminated and Counterfeit Refrigerants Using the Agilent 490 Micro GC
The importance of refrigerant composition analysis became clear when contaminated and counterfeit refrigerant 1,1,1,2-tetrafluorethane (R134a) appeared on the market.
- 응용 자료
- English
- 10 Jul 2015
- 459.51 KB
Halogenated hydrocarbons C2 – C2
Gas chromatography with an Agilent J&W PoraPLOT U column separates volatile halogenated hydrocarbons in a hydrocarbon/water mixture in less than four minutes.
- 응용 자료
- English
- 04 Jun 2014
- 537.93 KB
C2 Hydrocarbons and CO2
Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in 25 seconds.
- 응용 자료
- English
- 02 Jun 2014
- 746.00 KB
Hydrocarbons, C2, and CO2
Gas chromatography with an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC separates carbon dioxide and C2 hydrocarbons in a chlor-alkali cell in 60 seconds.
- 응용 자료
- English
- 02 Jun 2014
- 728.70 KB
Refrigerants
Fast GC analysis of halogenated refrigerant mixtures is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- 응용 자료
- English
- 30 May 2014
- 564.41 KB
Refrigerants
Fast GC analysis of refrigerant impurities in CFC-143A is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- 응용 자료
- English
- 30 May 2014
- 520.20 KB
- 브로셔
- 패키지 삽입
-
Agilent J&W PLOT Columns Installation and Conditioning
Installation and Conditioning Guide for Agilent J&W PLOT Columns
- 패키지 삽입
- English
- 17 Sep 2019
- 335.90 KB
AGILENT J&W PORAPLOT COLUMNS NOW HAVE INTEGRATED PARTICLE TRAPS
Insert describes how Agilent J&W PORAPLOT GC columns now have integrated particle traps at both ends. This allows leak-free connections and the use of an MS.
- 패키지 삽입
- English
- 12 Sep 2014
- 1.09 MB
www.agilent.com/chem/selectGC
The Agilent GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained.
Agilent offers a complete portfolio of supplies for all other major instrument brands, including Bruker, PerkinElmer, Waters, Thermo/Dionex and Shimadzu. These parts are manufactured to perform seamlessly with any of these instruments. These parts are backed by our same commitment to quality and our money back guarantee, as well as our worldwide technical support team, available to answer any question or concerns you may have.
Unsure which vials and closures are best suited to your application?
Quickly and easily find the perfect match using our selection tool: www.agilent.com/chem/SelectVials
GC 컬럼 설치 동영상 - GC 문제 해결 시리즈
- 00:16:50
GC 컬럼의 기초
- 00:15:56
GC 연결 향상
- 00:04:27